ISO/ASTM51205-09 Standard Practice for Use of a Ceric-Cerous Sulfate Dosimetry System

Published By Publication Date Number of Pages
ASTM 2009 12
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM ISO/ASTM51205-09

Historical Standard: Standard Practice for Use of a Ceric-Cerous Sulfate Dosimetry System

ASTM ISO/ASTM51205

Scope

1.1 This practice covers the preparation, testing, and procedure for using the ceric-cerous sulfate dosimetry system to measure absorbed dose in water when exposed to ionizing radiation. The system consists of a dosimeter and appropriate analytical instrumentation. For simplicity, the system will be referred to as the ceric-cerous system. It is classified as a reference standard dosimetry system (see ISO/ASTM Guide 51261). Ceric-cerous dosimeters are also used as transfer-standard dosimeters or routine dosimeters.

1.2 This practice describes both the spectrophotometric and the potentiometric readout procedures for the ceric-cerous systems.

1.3 This practice applies only to γ rays, X rays, and high energy electrons.

1.4 This practice applies provided the following are satisfied:

1.4.1 The absorbed-dose range shall be between 5 102 and 5 104 Gy (1).

1.4.2 The absorbed-dose rate shall be less than 10 6 Gy/s (1).

1.4.3 For radionuclide gamma-ray sources, the initial photon energy shall be greater than 0.6 MeV. For bremsstrahlung photons, the initial energy of the electrons used to produce the bremsstrahlung photons shall be equal to or greater than 2 MeV. For electron beams, the initial electron energy shall be greater than 8 MeV.

Note 1—The lower energy limits are appropriate for a cylindrical dosimeter ampoule of 12-mm diameter. Corrections for dose gradients across an ampoule of that diameter or less are not required for photons, but may be required for electron beams (2). The ceric-cerous system may be used at lower energies by employing thinner (in the beam direction) dosimeter containers (see ICRU Report 35).

1.4.4 The irradiation temperature of the dosimeter shall be between 0 and 62°C (3).

Note 2—The temperature coefficient of dosimeter response is known only in this range. For use outside this range, the dosimetry system should be calibrated for the required range of irradiation temperatures.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

absorbed dose; ceric-cerous sulfate dosimeter; dose; dose measurement; dosimeter; dosimetry system; electron beam; gamma radiation; ionizing radiation; irradiation; photons; radiation; radiation processing; reference-standard dosimeter; X rays; ICS