Electroacoustics. Simulators of human head and ear – Head and torso simulator for the measurement of air-conduction hearing aids

Published By Publication Date Number of Pages
BSI 2017 36
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC TS 60318-7:2017(E) describes a head and torso simulator, or manikin, intended for the measurement of air-conduction hearing aids in the frequency range from 100 Hz to 16 000 Hz. The manikin described in this document is intended for airborne acoustic measurements only. It is not suitable for measurements which depend upon vibration transmission paths such as bone conduction, or for measurements requiring the simulation of bone or tissue.  This document specifies the manikin in terms of both its geometrical dimensions and its acoustical properties. Only manikins compliant with both sets of specifications are in conformance with this document. This edition includes the following significant technical changes with respect to the previous edition: a)   the document is based on the designs of three different commonly used types of manikins; b)   the cross sections of the head and torso and pinna simulators of the previous edition are replaced by maximum and minimum values of their geometric dimensions; c)   the diffuse field frequency response of the manikin is added; d)   the usable frequency range is extended to 100 Hz to 16 000 Hz; e)   in addition to the cylindrical ear canal extension a tapered ear canal extension is added; f)   design examples of one anatomically shaped manikin and of two different geometrically shaped manikins are given in the annexes; g)   the relationship between tolerance interval, corresponding acceptance interval and the maximum permitted uncertainty of measurement are given in an annex; h)   3D representations of three different types of pinna simulators are given in an annex.

PDF Catalog

PDF Pages PDF Title
2 undefined
4 CONTENTS
6 FOREWORD
8 1 Scope
2 Normative references
9 3 Terms and definitions
12 Figures
Figure 1 – Manikin geometrical references
13 4 Construction
4.1 General
Figure 2 – Coordinate scheme for azimuth and elevation angles
14 4.2 Geometrical dimensions of the manikin
4.2.1 Head and torso
Figure 3 – Illustration of manikin head and torso dimensions
15 4.2.2 Pinna simulators for hearing aid measurements
Tables
Table 1 – Manikin head and torso dimensions
16 4.2.3 Ear canal extension
17 Figure 4 – Illustration of manikin pinna simulator dimensions
18 4.2.4 Ear simulator
Table 2 – Dimensions of the pinna simulator and the cylindrical ear canal extension of the manikin
Table 3 – Dimensions of the pinna simulator and the tapered ear canal extension of the manikin
19 4.2.5 Materials
4.3 Acoustical characteristics of the manikin
4.3.1 Free-field frequency response
20 Table 4 – Free-field frequency response of the manikin for an azimuth angle of 0° (right ear)
21 4.3.2 Diffuse-field frequency response
Table 5 – Free-field frequency responses of the manikin for azimuth angles of 90°, 180° and 270° (right ear)
22 4.3.3 Acceptance intervals
4.3.4 Openings
Table 6 – Diffuse-field frequency response of the manikin (right ear)
23 5 Calibration
5.1 Reference environmental conditions
5.2 Calibration method
5.2.1 General
5.2.2 Test signal, test space and measurement equipment
24 5.2.3 Measurement of sound pressure level
25 5.2.4 Alignment of manikin azimuth and elevation
5.2.5 Test for sound leakage
6 Marking and instruction manual
6.1 Markings of the manikin
6.2 Instruction manual
26 7 Maximum permitted uncertainty of measurements
27 Table 7 – Maximum permitted uncertainty Umax for type approval measurements
28 Annex A (informative)Design example of an anatomically shaped manikin
Figure A.1 – Example of an anatomically shaped manikin
29 Annex B (informative)Design examples of a geometrically shaped manikin
Figure B.1 – Example 1 of a geometrically shaped manikin
30 Figure B.2 – Example 2 of a geometrically shaped manikin
31 Annex C (informative)Relationship between tolerance interval, corresponding acceptance interval and the maximum permitted uncertainty of measurement
Figure C.1 – Relationship between tolerance interval, corresponding acceptance interval and the maximum permitted uncertainty of measurement
32 Annex D (informative)3D representation of example pinna simulators
D.1 Background
D.2 Scanning technique
D.3 Examples of pinna simulator shape
33 D.4 Verification of conformance
Figure D.1 – (Embedded 3D PDFs) – Examples of a pinna simulator
34 Bibliography