{"id":110772,"date":"2024-10-18T16:00:16","date_gmt":"2024-10-18T16:00:16","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-significantchangestotheirc-2012\/"},"modified":"2024-10-24T21:58:52","modified_gmt":"2024-10-24T21:58:52","slug":"icc-significantchangestotheirc-2012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-significantchangestotheirc-2012\/","title":{"rendered":"ICC SignificantChangestotheIRC 2012"},"content":{"rendered":"
If you are seeking a solid understanding of the latest updates to the International Residential Code<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Cover <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | PART 1 Administration (Chapter 1) <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | R105.2 Fences Exempt from Permit <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | PART 2 Definitions (Chapter 2) <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | R202 Definitions, Structural Composite Lumber <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | PART 3 Building Planning and Construction (Chapters 3 through 10) <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | R301.2.1 Wind Design Criteria <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | R301.2.1.2 Protection of Openings in Windborne Debris Regions <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | R301.2.2 Seismic Provisions <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Table R301.5 Minimum Uniformly Distributed Live Loads <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | R302.1 Exterior Walls <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | R302.2.2 Parapet Exception <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | R302.5.1 Garage Opening Protection <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | R303 Mechanical Ventilation <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | R303.5 Ventilation Intake Openings <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | R308.4 Hazardous Locations for Glazing <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | R308.4.5 Glazing and Wet Surfaces <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | R308.4.6 Glazing Adjacent Stairs and Ramps <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | R308.4.7 Glazing Adjacent to the Bottom Stair Landing <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | R309.5 Garage Fire Sprinklers <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | R310.1 Emergency Escape and Rescue Openings <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | R310.2.2 Window Well Drainage <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | R311.3.1 Floor Elevations at the Required Egress Door <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | R311.7.5 Stair Treads and Risers <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | R311.7.6 Landings for Stairways <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | R312 Guards and Window Fall Protection <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | R314 Smoke Alarms <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | R315.2 Carbon Monoxide Detection Systems <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | R316.4 Thermal Barrier <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | R316.5.13 Thermal Barrier for Floors <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | R404.1.9 Isolated Masonry Piers <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | R405.1 Foundation Drainage <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | R501.3 Fire Protection of Floors <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | R507 Decks <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | R602.1.1 End-Jointed Lumber <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | Table R602.3(1) Fastener Schedule for Structural Members <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | R602.7, Table R602.7.1 Single Member Headers <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | R602.10 and R602.12 Wall Bracing <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | R602.10.1 Braced Wall Lines <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | R602.10.2 Braced Wall Panels <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | R602.10.3 Required Length of Bracing <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | R602.10.4 Construction Methods for Braced Wall Panels <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | R602.10.5 Minimum Length of a Braced Wall Panel <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | R602.10.6 Construction of Methods ABW, PFH, PFG, CS-PF, and BV-WSP <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | R602.10.6.5 Wall Bracing for Dwellings with Stone and Masonry Veneer in Seismic Design Categories D[Sub(0)], D[Sub(1)], and D[Sub(2)] <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | R602.10.7 Ends of Braced Wall Lines with Continuous Sheathing <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | R602.10.9 Braced Wall Panel Support <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | R602.12 Simplified Wall Bracing <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | R602.12.6 Narrow Panels for Simplified Wall Bracing <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | R607.3 Installation of Wall Ties <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | R703.7.3.2 Masonry Veneer Lintel <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | R703.7.4 Masonry Veneer Anchorage <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | R703.7.4.2 Grout Fill Behind Masonry Veneer <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | R703.8 Flashing <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | R703.12 Adhered Masonry Veneer <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | R802.7 Cutting, Drilling, and Notching of Roof Members <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | R802.11 Roof Uplift Resistance <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | R806 Roof Ventilation <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | R806.5 Unvented Attic Assemblies <\/td>\n<\/tr>\n | ||||||
159<\/td>\n | R903.2.1 Roof Flashing Locations <\/td>\n<\/tr>\n | ||||||
161<\/td>\n | R903.2.2 Crickets and Saddles <\/td>\n<\/tr>\n | ||||||
162<\/td>\n | R905.2.7.2 Underlayment and High Wind <\/td>\n<\/tr>\n | ||||||
165<\/td>\n | R905.2.8.3 Sidewall Flashing <\/td>\n<\/tr>\n | ||||||
167<\/td>\n | R905.2.8.5 Roof Drip Edge <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | R907.3 Recovering versus Replacement Roofing <\/td>\n<\/tr>\n | ||||||
171<\/td>\n | R1003.9.1, R1003.9.3 Masonry Chimney Caps and Rain Caps <\/td>\n<\/tr>\n | ||||||
172<\/td>\n | R1005.7 Factory-Built Chimney Offsets <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | PART 4 Energy Conservation (Chapter 11) <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | N1101 Energy Efficiency <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | PART 5 Mechanical (Chapters 12 through 23) <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | M1301 Identification and Certification of Pipe, Tubing, and Fittings <\/td>\n<\/tr>\n | ||||||
179<\/td>\n | M1411.6 Locking Access Port Caps <\/td>\n<\/tr>\n | ||||||
180<\/td>\n | M1502.4 Dryer Exhaust Duct <\/td>\n<\/tr>\n | ||||||
182<\/td>\n | M1506 Exhaust Openings <\/td>\n<\/tr>\n | ||||||
184<\/td>\n | M1507 Mechanical Ventilation <\/td>\n<\/tr>\n | ||||||
188<\/td>\n | M1601.1 Above-Ground Duct Systems <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | M1601.4.1 Duct Joints, Seams, and Connections <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | M1602.2 Prohibited Sources of Outdoor and Return Air <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | M1901 Ranges and Ovens <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | M2301, M2302 Thermal and Photovoltaic Solar Energy Systems <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | PART 6 Fuel Gas (Chapter 24) <\/td>\n<\/tr>\n | ||||||
199<\/td>\n | G2409.1 Reduced Clearance to Combustible Materials <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | G2412, G2415 Pipe Identification and Certification <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | G2419.4 Sediment Trap <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | G2442.4 Prohibited Sources of Outdoor and Return Air <\/td>\n<\/tr>\n | ||||||
205<\/td>\n | PART 7 Plumbing (Chapters 25 through 33) <\/td>\n<\/tr>\n | ||||||
206<\/td>\n | P2503.5.1 Rough Plumbing Test <\/td>\n<\/tr>\n | ||||||
207<\/td>\n | P2601.2 Connections to Drainage System <\/td>\n<\/tr>\n | ||||||
209<\/td>\n | P2603.4 Pipes through Foundation Walls <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | P2606 Sealing of Annular Spaces <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | P2609.1, P2609.4 Identification and Certification <\/td>\n<\/tr>\n | ||||||
214<\/td>\n | P2702.1, P2706.1 Plumbing Fixtures <\/td>\n<\/tr>\n | ||||||
216<\/td>\n | P2709.1, P2709.2 Shower Receptors and Linings <\/td>\n<\/tr>\n | ||||||
219<\/td>\n | P2709.2.4 Liquid-Type Shower Lining <\/td>\n<\/tr>\n | ||||||
220<\/td>\n | P2713.1 Bathtub Waste Outlets and Overflows <\/td>\n<\/tr>\n | ||||||
221<\/td>\n | P2801.5 Required Water Heater Pan <\/td>\n<\/tr>\n | ||||||
223<\/td>\n | P2904.2.4.2 Minimum Fire Sprinkler Separation from Obstruction <\/td>\n<\/tr>\n | ||||||
225<\/td>\n | P3003.19 Joints between Drainage Piping and Water Closets <\/td>\n<\/tr>\n | ||||||
226<\/td>\n | P3007.3.5 Ejector Connection to the Drainage System <\/td>\n<\/tr>\n | ||||||
227<\/td>\n | P3009 Gray-Water Recycling Systems <\/td>\n<\/tr>\n | ||||||
230<\/td>\n | P3103.5 Location of Vent Terminal <\/td>\n<\/tr>\n | ||||||
232<\/td>\n | PART 8 Electrical (Chapters 34 through 43) <\/td>\n<\/tr>\n | ||||||
234<\/td>\n | E3608.1.2 Concrete-Encased Electrode <\/td>\n<\/tr>\n | ||||||
236<\/td>\n | E3608.4 Supplemental Electrode Required <\/td>\n<\/tr>\n | ||||||
238<\/td>\n | E3901.7 Outdoor Outlets <\/td>\n<\/tr>\n | ||||||
240<\/td>\n | E3901.11 Receptacle Outlets in Foyers <\/td>\n<\/tr>\n | ||||||
241<\/td>\n | E3902.11 Location of Ground-Fault Circuit Interrupters <\/td>\n<\/tr>\n | ||||||
242<\/td>\n | E3905.8 Boxes at Fan Outlets <\/td>\n<\/tr>\n | ||||||
244<\/td>\n | E4001.11.1 Switch and Faceplate Grounding <\/td>\n<\/tr>\n | ||||||
246<\/td>\n | E4001.15 Switches Controlling Lighting Loads <\/td>\n<\/tr>\n | ||||||
248<\/td>\n | E4002.14 Tamper-Resistant Receptacles <\/td>\n<\/tr>\n | ||||||
250<\/td>\n | E4204.2 Bonded Parts of Pools, Spas, and Hot Tubs <\/td>\n<\/tr>\n | ||||||
252<\/td>\n | E4209.3 Accessibility to Electrical Equipment of Hydromassage Bathtubs <\/td>\n<\/tr>\n | ||||||
254<\/td>\n | Index A B C <\/td>\n<\/tr>\n | ||||||
255<\/td>\n | D E F <\/td>\n<\/tr>\n | ||||||
256<\/td>\n | G H I K L M <\/td>\n<\/tr>\n | ||||||
257<\/td>\n | N O P R <\/td>\n<\/tr>\n | ||||||
258<\/td>\n | S T U V W <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Significant Changes to the International Residential Code, 2012 Edition<\/b><\/p>\n |