{"id":120193,"date":"2024-10-19T04:15:17","date_gmt":"2024-10-19T04:15:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-international-building-code-ibc-2000\/"},"modified":"2024-10-24T22:49:00","modified_gmt":"2024-10-24T22:49:00","slug":"icc-international-building-code-ibc-2000","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-international-building-code-ibc-2000\/","title":{"rendered":"ICC International Building Code (IBC) 2000"},"content":{"rendered":"

The IBC features time-tested safety concepts, updated means of egress and interior finish requirements, comprehensive roof provisions, seismic engineering provisions, innovative construction technology, revamped structural provisions, reorganized occupancy classifications and the latest industry standards in material design.<\/p>\n

<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nINTERNATIONAL BUILDING CODE <\/td>\n<\/tr>\n
2<\/td>\nCOPYRIGHT INFORMATION <\/td>\n<\/tr>\n
3<\/td>\nPREFACE <\/td>\n<\/tr>\n
5<\/td>\nSAMPLE ORDINANCE FOR ADOPTION <\/td>\n<\/tr>\n
7<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
13<\/td>\nCHAPTER 1: ADMINISTRATION
Section 101 — GENERAL
Section 102 — APPLICABILITY <\/td>\n<\/tr>\n
14<\/td>\nSection 103 — DEPARTMENT OF BUILDING SAFETY
Section 104 — DUTIES AND POWERS OF BUILDING OFFICIAL <\/td>\n<\/tr>\n
15<\/td>\nSection 105 — PERMITS <\/td>\n<\/tr>\n
17<\/td>\nSection 106 — CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n
19<\/td>\nSection 107 — TEMPORARY STRUCTURES AND USES
Section 108 — FEES <\/td>\n<\/tr>\n
20<\/td>\nSection 109 — INSPECTIONS <\/td>\n<\/tr>\n
21<\/td>\nSection 110 — CERTIFICATE OF OCCUPANCY
Section 111 — SERVICE UTILITIES
Section 112 — BOARD OF APPEALS <\/td>\n<\/tr>\n
22<\/td>\nSection 113 — VIOLATIONS
Section 114 — STOP WORK ORDER
Section 115 — UNSAFE STRUCTURES AND EQUIPMENT <\/td>\n<\/tr>\n
23<\/td>\nCHAPTER 2: DEFINITIONS
Section 201 — GENERAL
Section 202 — DEFINITIONS <\/td>\n<\/tr>\n
35<\/td>\nCHAPTER 3: USE AND OCCUPANCY CLASSIFICATION
Section 301 — GENERAL
Section 302 — CLASSIFICATION <\/td>\n<\/tr>\n
38<\/td>\nSection 303 — ASSEMBLY GROUP A
Section 304 — BUSINESS GROUP B
Section 305 — EDUCATIONAL GROUP E <\/td>\n<\/tr>\n
39<\/td>\nSection 306 — FACTORY GROUP F
Section 307 — HIGH-HAZARD GROUP H <\/td>\n<\/tr>\n
45<\/td>\nSection 308 — INSTITUTIONAL GROUP I <\/td>\n<\/tr>\n
48<\/td>\nSection 309 — MERCANTILE GROUP M
Section 310 — RESIDENTIAL GROUP R <\/td>\n<\/tr>\n
49<\/td>\nSection 311 — STORAGE GROUP S <\/td>\n<\/tr>\n
50<\/td>\nSection 312 — UTILITY AND MISCELLANEOUS GROUP U <\/td>\n<\/tr>\n
51<\/td>\nCHAPTER 4: SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
Section 401 — SCOPE
Section 402 — COVERED MALL BUILDINGS <\/td>\n<\/tr>\n
54<\/td>\nSection 403 — HIGH-RISE BUILDINGS <\/td>\n<\/tr>\n
55<\/td>\nSection 404 — ATRIUMS <\/td>\n<\/tr>\n
56<\/td>\nSection 405 — UNDERGROUND BUILDINGS <\/td>\n<\/tr>\n
57<\/td>\nSection 406 — MOTOR-VEHICLE-RELATED OCCUPANCIES <\/td>\n<\/tr>\n
61<\/td>\nSection 407 — GROUP I-2 <\/td>\n<\/tr>\n
63<\/td>\nSection 408 — GROUP I-3 <\/td>\n<\/tr>\n
65<\/td>\nSection 409 — MOTION PICTURE PROJECTION ROOMS
Section 410 — STAGES AND PLATFORMS <\/td>\n<\/tr>\n
68<\/td>\nSection 411 — SPECIAL AMUSEMENT BUILDINGS
Section 412 — AIRCRAFT-RELATED OCCUPANCIES <\/td>\n<\/tr>\n
71<\/td>\nSection 413 — COMBUSTIBLE STORAGE
Section 414 — HAZARDOUS MATERIALS <\/td>\n<\/tr>\n
75<\/td>\nSection 415 — GROUPS H-1, H-2, H-3, H-4 AND H-5 <\/td>\n<\/tr>\n
90<\/td>\nSection 416 — APPLICATION OF FLAMMABLE FINISHES
Section 417 — DRYING ROOMS
Section 418 — ORGANIC COATINGS <\/td>\n<\/tr>\n
91<\/td>\nCHAPTER 5: GENERAL BUILDING HEIGHTS AND AREAS
Section 501 — GENERAL
Section 502 — DEFINITIONS
Section 503 — GENERAL HEIGHT AND AREA LIMITATIONS <\/td>\n<\/tr>\n
93<\/td>\nSection 504 — HEIGHT MODIFICATIONS <\/td>\n<\/tr>\n
94<\/td>\nSection 505 — MEZZANINES <\/td>\n<\/tr>\n
95<\/td>\nSection 506 — AREA MODIFICATIONS
Section 507 — UNLIMITED AREA BUILDINGS <\/td>\n<\/tr>\n
96<\/td>\nSection 508 — SPECIAL PROVISIONS <\/td>\n<\/tr>\n
99<\/td>\nCHAPTER 6: TYPES OF CONSTRUCTION
Section 601 — GENERAL
Section 602 — CONSTRUCTION CLASSIFICATION <\/td>\n<\/tr>\n
100<\/td>\nSection 603 — COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION <\/td>\n<\/tr>\n
103<\/td>\nCHAPTER 7: FIRE-RESISTANCE-RATED CONSTRUCTION
Section 701 — GENERAL
Section 702 — DEFINITIONS <\/td>\n<\/tr>\n
104<\/td>\nSection 703 — FIRE-RESISTANCE RATINGS AND FIRE TESTS <\/td>\n<\/tr>\n
105<\/td>\nSection 704 — EXTERIOR WALLS <\/td>\n<\/tr>\n
109<\/td>\nSection 705 — FIRE WALLS <\/td>\n<\/tr>\n
112<\/td>\nSection 706 — FIRE BARRIERS
Section 707 — SHAFT AND VERTICAL EXIT ENCLOSURES <\/td>\n<\/tr>\n
115<\/td>\nSection 708 — FIRE PARTITIONS <\/td>\n<\/tr>\n
116<\/td>\nSection 709 — SMOKE BARRIERS
Section 710 — HORIZONTAL ASSEMBLIES <\/td>\n<\/tr>\n
117<\/td>\nSection 711 — PENETRATIONS <\/td>\n<\/tr>\n
119<\/td>\nSection 712 — FIRE-RESISTANT JOINT SYSTEMS <\/td>\n<\/tr>\n
120<\/td>\nSection 713 — FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS <\/td>\n<\/tr>\n
121<\/td>\nSection 714 — OPENING PROTECTIVES <\/td>\n<\/tr>\n
124<\/td>\nSection 715 — DUCTS AND AIR TRANSFER OPENINGS <\/td>\n<\/tr>\n
127<\/td>\nSection 716 — CONCEALED SPACES <\/td>\n<\/tr>\n
129<\/td>\nSection 717 — FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
Section 718 — THERMAL- AND SOUND-INSULATING MATERIALS <\/td>\n<\/tr>\n
130<\/td>\nSection 719 — PRESCRIPTIVE FIRE RESISTANCE <\/td>\n<\/tr>\n
152<\/td>\nSection 720 — CALCULATED FIRE RESISTANCE <\/td>\n<\/tr>\n
183<\/td>\nCHAPTER 8: INTERIOR FINISHES
Section 801 — GENERAL
Section 802 — DEFINITIONS
Section 803 — WALL AND CEILING FINISHES <\/td>\n<\/tr>\n
186<\/td>\nSection 804 — INTERIOR FLOOR FINISH <\/td>\n<\/tr>\n
187<\/td>\nSection 805 — DECORATIONS AND TRIM <\/td>\n<\/tr>\n
189<\/td>\nCHAPTER 9: FIRE PROTECTION SYSTEMS
Section 901 — GENERAL
Section 902 — DEFINITIONS <\/td>\n<\/tr>\n
192<\/td>\nSection 903 — AUTOMATIC SPRINKLER SYSTEMS <\/td>\n<\/tr>\n
197<\/td>\nSection 904 — ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS <\/td>\n<\/tr>\n
199<\/td>\nSection 905 — STANDPIPE SYSTEMS <\/td>\n<\/tr>\n
201<\/td>\nSection 906 — PORTABLE FIRE EXTINGUISHERS
Section 907 — FIRE ALARM AND DETECTION SYSTEMS <\/td>\n<\/tr>\n
210<\/td>\nSection 908 — EMERGENCY ALARM SYSTEMS <\/td>\n<\/tr>\n
211<\/td>\nSection 909 — SMOKE CONTROL SYSTEMS <\/td>\n<\/tr>\n
220<\/td>\nSection 910 — SMOKE AND HEAT VENTS <\/td>\n<\/tr>\n
222<\/td>\nSection 911 — FIRE COMMAND CENTER <\/td>\n<\/tr>\n
223<\/td>\nCHAPTER 10: MEANS OF EGRESS
Section 1001 — ADMINISTRATION
Section 1002 — DEFINITIONS <\/td>\n<\/tr>\n
224<\/td>\nSection 1003 — GENERAL MEANS OF EGRESS <\/td>\n<\/tr>\n
242<\/td>\nSection 1004 — EXIT ACCESS <\/td>\n<\/tr>\n
247<\/td>\nSection 1005 — EXITS <\/td>\n<\/tr>\n
251<\/td>\nSection 1006 — EXIT DISCHARGE <\/td>\n<\/tr>\n
253<\/td>\nSection 1007 — MISCELLANEOUS MEANS OF EGRESS REQUIREMENTS
Section 1008 — ASSEMBLY <\/td>\n<\/tr>\n
258<\/td>\nSection 1009 — EMERGENCY ESCAPE AND RESCUE <\/td>\n<\/tr>\n
261<\/td>\nCHAPTER 11: ACCESSIBILITY
Section 1101 — GENERAL
Section 1102 — DEFINITIONS
Section 1103 — SCOPING REQUIREMENTS <\/td>\n<\/tr>\n
262<\/td>\nSection 1104 — ACCESSIBLE ROUTE <\/td>\n<\/tr>\n
263<\/td>\nSection 1105 — ACCESSIBLE ENTRANCES
Section 1106 — PARKING AND PASSENGER LOADING FACILITIES
Section 1107 — SPECIAL OCCUPANCIES <\/td>\n<\/tr>\n
267<\/td>\nSection 1108 — OTHER FEATURES AND FACILITIES <\/td>\n<\/tr>\n
269<\/td>\nSection 1109 — SIGNAGE <\/td>\n<\/tr>\n
271<\/td>\nCHAPTER 12: INTERIOR ENVIRONMENT
Section 1201 — GENERAL
Section 1202 — VENTILATION <\/td>\n<\/tr>\n
272<\/td>\nSection 1203 — TEMPERATURE CONTROL
Section 1204 — LIGHTING <\/td>\n<\/tr>\n
273<\/td>\nSection 1205 — YARDS OR COURTS
Section 1206 — SOUND TRANSMISSION
Section 1207 — INTERIOR SPACE DIMENSIONS <\/td>\n<\/tr>\n
274<\/td>\nSection 1208 — ACCESS TO UNOCCUPIED SPACES
Section 1209 — SURROUNDING MATERIALS <\/td>\n<\/tr>\n
275<\/td>\nCHAPTER 13: ENERGY EFFICIENCY
Section 1301 — GENERAL <\/td>\n<\/tr>\n
277<\/td>\nCHAPTER 14: EXTERIOR WALLS
Section 1401 — GENERAL
Section 1402 — DEFINITIONS
Section 1403 — PERFORMANCE REQUIREMENTS <\/td>\n<\/tr>\n
278<\/td>\nSection 1404 — MATERIALS
Section 1405 — INSTALLATION OF WALL COVERINGS <\/td>\n<\/tr>\n
282<\/td>\nSection 1406 — COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS <\/td>\n<\/tr>\n
284<\/td>\nSection 1407 — ALUMINUM COMPOSITE MATERIALS (ACM) <\/td>\n<\/tr>\n
287<\/td>\nCHAPTER 15: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Section 1501 — GENERAL
Section 1502 — DEFINITIONS <\/td>\n<\/tr>\n
288<\/td>\nSection 1503 — WEATHER PROTECTION
Section 1504 — PERFORMANCE REQUIREMENTS
Section 1505 — FIRE CLASSIFICATION <\/td>\n<\/tr>\n
289<\/td>\nSection 1506 — MATERIALS
Section 1507 — REQUIREMENTS FOR ROOF COVERINGS <\/td>\n<\/tr>\n
300<\/td>\nSection 1508 — ROOF INSULATION
Section 1509 — ROOFTOP STRUCTURES <\/td>\n<\/tr>\n
302<\/td>\nSection 1510 — REROOFING <\/td>\n<\/tr>\n
303<\/td>\nCHAPTER 16: STRUCTURAL DESIGN
Section 1601 — GENERAL
Section 1602 — DEFINITIONS <\/td>\n<\/tr>\n
306<\/td>\nSection 1603 — CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n
307<\/td>\nSection 1604 — GENERAL DESIGN REQUIREMENTS <\/td>\n<\/tr>\n
308<\/td>\nSection 1605 — LOAD COMBINATIONS <\/td>\n<\/tr>\n
311<\/td>\nSection 1606 — DEAD LOADS
Section 1607 — LIVE LOADS <\/td>\n<\/tr>\n
316<\/td>\nSection 1608 — SNOW LOADS <\/td>\n<\/tr>\n
317<\/td>\nSection 1609 — WIND LOADS <\/td>\n<\/tr>\n
324<\/td>\nSection 1610 — SOIL LATERAL LOAD <\/td>\n<\/tr>\n
325<\/td>\nSection 1611 — RAIN LOADS
Section 1612 — FLOOD LOADS <\/td>\n<\/tr>\n
341<\/td>\nSection 1613 — EARTHQUAKE LOADS DEFINITIONS <\/td>\n<\/tr>\n
342<\/td>\nSection 1614 — EARTHQUAKE LOADS\u2014GENERAL <\/td>\n<\/tr>\n
343<\/td>\nSection 1615 — EARTHQUAKE LOADS\u2014SITE GROUND MOTION <\/td>\n<\/tr>\n
366<\/td>\nSection 1616 — EARTHQUAKE LOADS\u2014CRITERIA SELECTION <\/td>\n<\/tr>\n
369<\/td>\nSection 1617 — EARTHQUAKE LOADS\u2014MINIMUM DESIGN LATERAL FORCE AND RELATED EFFECTS <\/td>\n<\/tr>\n
381<\/td>\nSection 1618 — DYNAMIC ANALYSIS PROCEDURE FOR THE SEISMIC DESIGN OF BUILDINGS <\/td>\n<\/tr>\n
384<\/td>\nSection 1619 — EARTHQUAKE LOADS SOIL-STRUCTURE INTERACTION EFFECTS
Section 1620 — EARTHQUAKE LOADS\u2014DESIGN, DETAILING REQUIREMENTS AND STRUCTURAL COMPONENT LOAD EFFECTS <\/td>\n<\/tr>\n
387<\/td>\nSection 1621 — ARCHITECTURAL, MECHANICAL AND ELECTRICAL COMPONENT SEISMIC DESIGN REQUIREMENTS <\/td>\n<\/tr>\n
398<\/td>\nSection 1622 — NONBUILDING STRUCTURES SEISMIC DESIGN REQUIREMENTS <\/td>\n<\/tr>\n
404<\/td>\nSection 1623 — SEISMICALLY ISOLATED STRUCTURES <\/td>\n<\/tr>\n
417<\/td>\nCHAPTER 17: STRUCTURAL TESTS AND SPECIAL INSPECTIONS
Section 1701 — GENERAL
Section 1702 — DEFINITIONS <\/td>\n<\/tr>\n
418<\/td>\nSection 1703 — APPROVALS <\/td>\n<\/tr>\n
419<\/td>\nSection 1704 — SPECIAL INSPECTIONS <\/td>\n<\/tr>\n
426<\/td>\nSection 1705 — QUALITY ASSURANCE FOR SEISMIC RESISTANCE <\/td>\n<\/tr>\n
427<\/td>\nSection 1706 — QUALITY ASSURANCE FOR WIND REQUIREMENTS <\/td>\n<\/tr>\n
428<\/td>\nSection 1707 — SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE <\/td>\n<\/tr>\n
429<\/td>\nSection 1708 — STRUCTURAL TESTING FOR SEISMIC RESISTANCE <\/td>\n<\/tr>\n
430<\/td>\nSection 1709 — STRUCTURAL OBSERVATIONS <\/td>\n<\/tr>\n
431<\/td>\nSection 1710 — DESIGN STRENGTHS OF MATERIALS
Section 1711 — ALTERNATIVE TEST PROCEDURE
Section 1712 — TEST SAFE LOAD
Section 1713 — IN-SITU LOAD TESTS <\/td>\n<\/tr>\n
432<\/td>\nSection 1714 — PRECONSTRUCTION LOAD TESTS <\/td>\n<\/tr>\n
433<\/td>\nSection 1715 — MATERIAL AND TEST STANDARDS <\/td>\n<\/tr>\n
435<\/td>\nCHAPTER 18: SOILS AND FOUNDATIONS
Section 1801 — GENERAL
Section 1802 — FOUNDATION AND SOILS INVESTIGATIONS <\/td>\n<\/tr>\n
436<\/td>\nSection 1803 — EXCAVATION, GRADING AND FILL <\/td>\n<\/tr>\n
437<\/td>\nSection 1804 — ALLOWABLE LOAD-BEARING VALUES OF SOILS
Section 1805 — FOOTINGS AND FOUNDATIONS <\/td>\n<\/tr>\n
446<\/td>\nSection 1806 — DAMPPROOFING AND WATERPROOFING <\/td>\n<\/tr>\n
448<\/td>\nSection 1807 — PIER AND PILE FOUNDATIONS <\/td>\n<\/tr>\n
453<\/td>\nSection 1808 — DRIVEN PILE FOUNDATIONS <\/td>\n<\/tr>\n
456<\/td>\nSection 1809 — CAST-IN-PLACE CONCRETE PILE FOUNDATIONS <\/td>\n<\/tr>\n
460<\/td>\nSection 1810 — COMPOSITE PILES
Section 1811 — PIER FOUNDATIONS <\/td>\n<\/tr>\n
463<\/td>\nCHAPTER 19: CONCRETE
Section 1901 — GENERAL
Section 1902 — DEFINITIONS <\/td>\n<\/tr>\n
464<\/td>\nSection 1903 — SPECIFICATIONS FOR TESTS AND MATERIALS <\/td>\n<\/tr>\n
465<\/td>\nSection 1904 — DURABILITY REQUIREMENTS <\/td>\n<\/tr>\n
467<\/td>\nSection 1905 — CONCRETE QUALITY, MIXING AND PLACING <\/td>\n<\/tr>\n
472<\/td>\nSection 1906 — FORMWORK, EMBEDDED PIPES AND CONSTRUCTION JOINTS <\/td>\n<\/tr>\n
473<\/td>\nSection 1907 — DETAILS OF REINFORCEMENT <\/td>\n<\/tr>\n
475<\/td>\nSection 1908 — MODIFICATIONS TO ACI 318 <\/td>\n<\/tr>\n
478<\/td>\nSection 1909 — STRUCTURAL PLAIN CONCRETE <\/td>\n<\/tr>\n
479<\/td>\nSection 1910 — SEISMIC DESIGN PROVISIONS <\/td>\n<\/tr>\n
480<\/td>\nSection 1911 — MINIMUM SLAB PROVISIONS <\/td>\n<\/tr>\n
481<\/td>\nSection 1912 — ANCHORAGE TO CONCRETE\u2014ALLOWABLE STRESS DESIGN <\/td>\n<\/tr>\n
482<\/td>\nSection 1913 — ANCHORAGE TO CONCRETE\u2014STRENGTH DESIGN <\/td>\n<\/tr>\n
489<\/td>\nSection 1914 — SHOTCRETE <\/td>\n<\/tr>\n
491<\/td>\nSection 1915 — REINFORCED GYPSUM CONCRETE
Section 1916 — CONCRETE-FILLED PIPE COLUMNS <\/td>\n<\/tr>\n
493<\/td>\nCHAPTER 20: ALUMINUM
Section 2001 — GENERAL
Section 2002 — MATERIALS <\/td>\n<\/tr>\n
495<\/td>\nCHAPTER 21: MASONRY
Section 2101 — GENERAL
Section 2102 — DEFINITIONS AND NOTATIONS <\/td>\n<\/tr>\n
500<\/td>\nSection 2103 — MASONRY CONSTRUCTION MATERIALS <\/td>\n<\/tr>\n
503<\/td>\nSection 2104 — CONSTRUCTION <\/td>\n<\/tr>\n
505<\/td>\nSection 2105 — QUALITY ASSURANCE <\/td>\n<\/tr>\n
507<\/td>\nSection 2106 — SEISMIC DESIGN <\/td>\n<\/tr>\n
510<\/td>\nSection 2107 — WORKING STRESS DESIGN <\/td>\n<\/tr>\n
511<\/td>\nSection 2108 — STRENGTH DESIGN OF MASONRY <\/td>\n<\/tr>\n
527<\/td>\nSection 2109 — EMPIRICAL DESIGN OF MASONRY <\/td>\n<\/tr>\n
534<\/td>\nSection 2110 — GLASS UNIT MASONRY <\/td>\n<\/tr>\n
535<\/td>\nSection 2111 — MASONRY FIREPLACES <\/td>\n<\/tr>\n
540<\/td>\nSection 2112 — MASONRY HEATERS
Section 2113 — MASONRY CHIMNEYS <\/td>\n<\/tr>\n
545<\/td>\nCHAPTER 22: STEEL
Section 2201 — GENERAL
Section 2202 — DEFINITIONS AND NOMENCLATURE
Section 2203 — IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURES
Section 2204 — STRUCTURAL STEEL CONSTRUCTION
Section 2205 — COLD-FORMED STEEL
Section 2206 — STEEL JOISTS <\/td>\n<\/tr>\n
546<\/td>\nSection 2207 — STEEL CABLE STRUCTURES
Section 2208 — WELDING
Section 2209 — BOLTING
Section 2210 — STEEL STORAGE RACKS
Section 2211 — WIND AND SEISMIC REQUIREMENTS FOR LIGHT FRAMED COLD-FORMED STEEL WALLS <\/td>\n<\/tr>\n
548<\/td>\nSection 2212 — SEISMIC REQUIREMENTS FOR STRUCTURAL STEEL CONSTRUCTION
Section 2213 — SEISMIC REQUIREMENTS FOR COMPOSITE CONSTRUCTION <\/td>\n<\/tr>\n
551<\/td>\nCHAPTER 23: WOOD
Section 2301 — GENERAL
Section 2302 — DEFINITIONS <\/td>\n<\/tr>\n
553<\/td>\nSection 2303 — MINIMUM STANDARDS AND QUALITY <\/td>\n<\/tr>\n
555<\/td>\nSection 2304 — GENERAL CONSTRUCTION REQUIREMENTS <\/td>\n<\/tr>\n
564<\/td>\nSection 2305 — GENERAL DESIGN REQUIREMENTS FOR LATERAL-FORCE-RESISTING SYSTEMS <\/td>\n<\/tr>\n
571<\/td>\nSection 2306 — ALLOWABLE STRESS DESIGN <\/td>\n<\/tr>\n
580<\/td>\nSection 2307 — LOAD AND RESISTANCE FACTOR DESIGN
Section 2308 — CONVENTIONAL LIGHT-FRAME CONSTRUCTION <\/td>\n<\/tr>\n
613<\/td>\nCHAPTER 24: GLASS AND GLAZING
Section 2401 — GENERAL
Section 2402 — DEFINITIONS
Section 2403 — GENERAL REQUIREMENTS FOR GLASS
Section 2404 — WIND, SNOW AND DEAD LOADS ON GLASS <\/td>\n<\/tr>\n
615<\/td>\nSection 2405 — SLOPED GLAZING AND SKYLIGHTS <\/td>\n<\/tr>\n
628<\/td>\nSection 2406 — SAFETY GLAZING <\/td>\n<\/tr>\n
630<\/td>\nSection 2407 — GLASS IN HANDRAILS AND GUARDS
Section 2408 — GLAZING IN ATHLETIC FACILITIES
Section 2409 — GLASS IN FLOORS AND SIDEWALKS <\/td>\n<\/tr>\n
633<\/td>\nCHAPTER 25: GYPSUM BOARD AND PLASTER
Section 2501 — GENERAL
Section 2502 — DEFINITIONS
Section 2503 — INSPECTION
Section 2504 — VERTICAL AND HORIZONTAL ASSEMBLIES <\/td>\n<\/tr>\n
634<\/td>\nSection 2505 — SHEAR WALL CONSTRUCTION
Section 2506 — GYPSUM BOARD MATERIALS
Section 2507 — LATHING AND PLASTERING <\/td>\n<\/tr>\n
635<\/td>\nSection 2508 — GYPSUM CONSTRUCTION
Section 2509 — GYPSUM BOARD IN SHOWERS AND WATER CLOSETS
Section 2510 — LATHING AND FURRING FOR CEMENT PLASTER (STUCCO) <\/td>\n<\/tr>\n
636<\/td>\nSection 2511 — INTERIOR PLASTER <\/td>\n<\/tr>\n
637<\/td>\nSection 2512 — EXTERIOR PLASTER
Section 2513 — EXPOSED AGGREGATE PLASTER <\/td>\n<\/tr>\n
639<\/td>\nCHAPTER 26: PLASTIC
Section 2601 — GENERAL
Section 2602 — DEFINITIONS
Section 2603 — FOAM PLASTIC INSULATION <\/td>\n<\/tr>\n
642<\/td>\nSection 2604 — INTERIOR FINISH AND TRIM
Section 2605 — PLASTIC VENEER <\/td>\n<\/tr>\n
643<\/td>\nSection 2606 — LIGHT-TRANSMITTING PLASTICS <\/td>\n<\/tr>\n
644<\/td>\nSection 2607 — LIGHT-TRANSMITTING PLASTIC WALL PANELS <\/td>\n<\/tr>\n
645<\/td>\nSection 2608 — LIGHT-TRANSMITTING PLASTIC GLAZING
Section 2609 — LIGHT-TRANSMITTING PLASTIC ROOF PANELS <\/td>\n<\/tr>\n
646<\/td>\nSection 2610 — LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING <\/td>\n<\/tr>\n
647<\/td>\nSection 2611 — LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS <\/td>\n<\/tr>\n
649<\/td>\nCHAPTER 27: ELECTRICAL
Section 2701 — GENERAL
Section 2702 — EMERGENCY AND STANDBY POWER SYSTEMS <\/td>\n<\/tr>\n
651<\/td>\nCHAPTER 28: MECHANICAL SYSTEMS
Section 2801 — GENERAL <\/td>\n<\/tr>\n
653<\/td>\nCHAPTER 29: PLUMBING SYSTEMS
Section 2901 — GENERAL
Section 2902 — MINIMUM PLUMBING FACILITIES <\/td>\n<\/tr>\n
657<\/td>\nCHAPTER 30: ELEVATORS AND CONVEYING SYSTEMS
Section 3001 — GENERAL
Section 3002 — HOISTWAY ENCLOSURES
Section 3003 — EMERGENCY OPERATIONS <\/td>\n<\/tr>\n
658<\/td>\nSection 3004 — HOISTWAY VENTING
Section 3005 — CONVEYING SYSTEMS <\/td>\n<\/tr>\n
659<\/td>\nSection 3006 — MACHINE ROOMS <\/td>\n<\/tr>\n
661<\/td>\nCHAPTER 31: SPECIAL CONSTRUCTION
Section 3101 — GENERAL
Section 3102 — MEMBRANE STRUCTURES <\/td>\n<\/tr>\n
662<\/td>\nSection 3103 — TEMPORARY STRUCTURES <\/td>\n<\/tr>\n
663<\/td>\nSection 3104 — PEDESTRIAN WALKWAYS AND TUNNELS <\/td>\n<\/tr>\n
664<\/td>\nSection 3105 — AWNINGS AND CANOPIES
Section 3106 — MARQUEES
Section 3107 — SIGNS
Section 3108 — RADIO AND TELEVISION TOWERS <\/td>\n<\/tr>\n
665<\/td>\nSection 3109 — SWIMMING POOL ENCLOSURES <\/td>\n<\/tr>\n
667<\/td>\nCHAPTER 32: ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
Section 3201 — GENERAL
Section 3202 — ENCROACHMENTS <\/td>\n<\/tr>\n
669<\/td>\nCHAPTER 33: SAFEGUARDS DURING CONSTRUCTION
Section 3301 — GENERAL
Section 3302 — CONSTRUCTION SAFEGUARDS
Section 3303 — DEMOLITION
Section 3304 — SITE WORK <\/td>\n<\/tr>\n
670<\/td>\nSection 3305 — SANITARY
Section 3306 — PROTECTION OF PEDESTRIANS <\/td>\n<\/tr>\n
671<\/td>\nSection 3307 — PROTECTION OF ADJOINING PROPERTY
Section 3308 — TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
Section 3309 — FIRE EXTINGUISHERS <\/td>\n<\/tr>\n
672<\/td>\nSection 3310 — EXITS
Section 3311 — STANDPIPES
Section 3312 — AUTOMATIC SPRINKLER SYSTEM <\/td>\n<\/tr>\n
673<\/td>\nCHAPTER 34: EXISTING STRUCTURES
Section 3401 — GENERAL
Section 3402 — ADDITIONS, ALTERATIONS OR REPAIRS
Section 3403 — FIRE ESCAPES <\/td>\n<\/tr>\n
674<\/td>\nSection 3404 — GLASS REPLACEMENT
Section 3405 — CHANGE OF OCCUPANCY
Section 3406 — HISTORIC BUILDINGS
Section 3407 — MOVED STRUCTURES
Section 3408 — ACCESSIBILITY FOR EXISTING BUILDINGS <\/td>\n<\/tr>\n
676<\/td>\nSection 3409 — COMPLIANCE ALTERNATIVES <\/td>\n<\/tr>\n
687<\/td>\nCHAPTER 35: REFERENCED STANDARDS <\/td>\n<\/tr>\n
711<\/td>\nAPPENDIX A: EMPLOYEE QUALIFICATIONS
Section A101 — BUILDING OFFICIAL QUALIFICATIONS
Section A102 — REFERENCED STANDARDS <\/td>\n<\/tr>\n
713<\/td>\nAPPENDIX B: BOARD OF APPEALS
Section B101 — GENERAL <\/td>\n<\/tr>\n
715<\/td>\nAPPENDIX C: GROUP U – AGRICULTURAL BUILDINGS
Section C101 — GENERAL
Section C102 — ALLOWABLE HEIGHT AND AREA
Section C103 — MIXED USES
Section C104 — EXITS <\/td>\n<\/tr>\n
717<\/td>\nAPPENDIX D: FIRE DISTRICTS
Section D101 — GENERAL
Section D102 — BUILDING RESTRICTIONS <\/td>\n<\/tr>\n
718<\/td>\nSection D103 — CHANGES TO BUILDINGS
Section D104 — BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
Section D105 — EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT <\/td>\n<\/tr>\n
719<\/td>\nSection D106 — REFERENCED STANDARDS <\/td>\n<\/tr>\n
721<\/td>\nAPPENDIX E: SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
Section E1101 — GENERAL
Section E1102 — DEFINITIONS
Section E1103 — ACCESSIBLE ROUTE
Section E1104 — SPECIAL OCCUPANCIES <\/td>\n<\/tr>\n
722<\/td>\nSection E1105 — OTHER FEATURES AND FACILITIES
Section E1106 — TELEPHONES <\/td>\n<\/tr>\n
723<\/td>\nSection E1107 — SIGNAGE
Section E1108 — BUS STOPS AND TERMINALS <\/td>\n<\/tr>\n
724<\/td>\nSection E1109 — FIXED TRANSPORTATION FACILITIES AND STATIONS <\/td>\n<\/tr>\n
725<\/td>\nSection E1110 — AIRPORTS <\/td>\n<\/tr>\n
726<\/td>\nSection E1111 — REFERENCED STANDARDS <\/td>\n<\/tr>\n
727<\/td>\nAPPENDIX F: RODENT PROOFING
Section F101 — GENERAL <\/td>\n<\/tr>\n
729<\/td>\nAPPENDIX G: FLOOD RESISTANT CONSTRUCTION
Section G101 — ADMINISTRATION
Section G102 — APPLICABILITY
Section G103 — POWERS AND DUTIES <\/td>\n<\/tr>\n
730<\/td>\nSection G104 — PERMITS <\/td>\n<\/tr>\n
731<\/td>\nSection G105 — VARIANCES
Section G201 — DEFINITIONS <\/td>\n<\/tr>\n
732<\/td>\nSection G301 — SUBDIVISIONS
Section G401 — SITE IMPROVEMENT <\/td>\n<\/tr>\n
733<\/td>\nSection G501 — MANUFACTURED HOMES
Section G601 — RECREATIONAL VEHICLES
Section G701 — REFERENCED STANDARDS <\/td>\n<\/tr>\n
735<\/td>\nAPPENDIX H: SIGNS
Section H101 — GENERAL
Section H102 — DEFINITIONS
Section H103 — LOCATION
Section H104 — IDENTIFICATION <\/td>\n<\/tr>\n
736<\/td>\nSection H105 — DESIGN AND CONSTRUCTION
Section H106 — ELECTRICAL
Section H107 — COMBUSTIBLE MATERIALS <\/td>\n<\/tr>\n
737<\/td>\nSection H108 — ANIMATED DEVICES
Section H109 — GROUND SIGNS
Section H110 — ROOF SIGNS
Section H111 — WALL SIGNS
Section H112 — PROJECTING SIGNS <\/td>\n<\/tr>\n
738<\/td>\nSection H113 — MARQUEE SIGNS
Section H114 — PORTABLE SIGNS <\/td>\n<\/tr>\n
739<\/td>\nSection H115 — REFERENCED STANDARDS <\/td>\n<\/tr>\n
741<\/td>\nAPPENDIX I: PATIO COVERS
Section I101 — GENERAL
Section I102 — DEFINITIONS
Section I103 — EXTERIOR OPENINGS
Section I104 — STRUCTURAL PROVISIONS <\/td>\n<\/tr>\n
743<\/td>\nAPPENDIX J: SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS FOR QUALIFIED HISTORIC BUILDINGS AND FACILITIES
Section J101 — ACCESSIBILITY PROVISIONS
Section J102 — REFERENCED STANDARDS <\/td>\n<\/tr>\n
745<\/td>\nINDEX
A <\/td>\n<\/tr>\n
746<\/td>\nB <\/td>\n<\/tr>\n
747<\/td>\nC <\/td>\n<\/tr>\n
749<\/td>\nD
E <\/td>\n<\/tr>\n
750<\/td>\nF <\/td>\n<\/tr>\n
752<\/td>\nG <\/td>\n<\/tr>\n
753<\/td>\nH <\/td>\n<\/tr>\n
755<\/td>\nI
J
K
L <\/td>\n<\/tr>\n
756<\/td>\nM <\/td>\n<\/tr>\n
758<\/td>\nN
O
P <\/td>\n<\/tr>\n
760<\/td>\nR <\/td>\n<\/tr>\n
761<\/td>\nS <\/td>\n<\/tr>\n
764<\/td>\nT <\/td>\n<\/tr>\n
765<\/td>\nU <\/td>\n<\/tr>\n
766<\/td>\nV
W <\/td>\n<\/tr>\n
767<\/td>\nY <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

International Building Code<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ICC<\/b><\/a><\/td>\n2000<\/td>\n768<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":120194,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2670],"product_tag":[],"class_list":{"0":"post-120193","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-icc","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/120193","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/120194"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=120193"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=120193"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=120193"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}