{"id":139791,"date":"2024-10-19T08:06:43","date_gmt":"2024-10-19T08:06:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/vt-vermontresidentialbuildingenergystandards-2015\/"},"modified":"2024-10-25T00:19:54","modified_gmt":"2024-10-25T00:19:54","slug":"vt-vermontresidentialbuildingenergystandards-2015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/vt\/vt-vermontresidentialbuildingenergystandards-2015\/","title":{"rendered":"VT VermontResidentialBuildingEnergyStandards 2015"},"content":{"rendered":"
Custom code based on the Residential provisions of the 2015 International Energy Conservation Code.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 2015 VERMONT RESIDENTIAL BUILDING ENERGY STANDARDS <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | 2015 VERMONT RESIDENTIAL BUILDING ENERGY STANDARDS TITLE PAGE <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | COPYRIGHT <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | PREFACE <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | EFFECTIVE USE OF THE2 015 RESIDENTIAL BUILDING ENERGY STANDARDS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | CHAPTER 1 [RE] ADMINISTRATION PART 1\u2014SCOPE AND APPLICATION SECTION R101 SCOPE AND GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | SECTION R102 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT PART 2\u2014ADMINISTRATION AND ENFORCEMENT SECTION R103 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | SECTION R104 INSPECTIONS SECTION R105 VALIDITY SECTION R106 REFERENCED STANDARDS <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | CHAPTER 2 [RE] DEFINITIONS SECTION R201 GENERAL SECTION R202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | CHAPTER 3 [RE] GENERAL REQUIREMENTS SECTION R301 [RESERVED] SECTION R302 DESIGN CONDITIONS TABLE 302.2 THERMAL DESIGN PARAMETERS SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT SECTION 304 DESIGN CRITERIA FOR RESIDENTIAL VENTILATION SYSTEMS TABLE 304.2 MINIMUM REQUIRED LOCAL EXHAUST <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | TABLE 304.6 PRESCRIPTIVE FAN CAPACITY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | SECTION 305 COMBUSTION SAFETY (MANDATORY) <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY SECTION R401 GENERAL SECTION R402 BUILDING THERMAL ENVELOPE <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT TABLE R402.1.4 EQUIVALENT U-FACTORS <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | TABLE R402.1.5 LOG HOME INSULATION, FENESTRATION AND HEATING REQUIREMENTS BY COMPONENTa <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | TABLE R402.4.1.1\u2014continued AIR BARRIER AND INSULATION INSTALLATION <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | SECTION R403 SYSTEMS <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | TABLE R403.6.1 MECHANICAL VENTILATION SYSTEM FAN EFFICACY SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE USING RESCHECKTM SOFTWARE (PERFORMANCE) SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE TABLE 406.4 MAXIMUM BASE CODE ENERGY RATING INDEX <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | TABLE R407.1 STRETCH CODE REQUIREMENTS BY COMPONENTa <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | SECTION R407 VERMONT STRETCH CODE TABLE R407.2 MAXIMUM STRETCH CODE ENERGY RATING INDEX TABLE 407.3 <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | CHAPTER 5 (RE) EXISTING BUILDINGS SECTION R501 GENERAL SECTION R502 ADDITIONS <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | SECTION R503 ALTERATIONS SECTION R504 REPAIRS <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | SECTION R505 CHANGE OF OCCUPANCY OR USE <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | CHAPTER 6 REFERENCED STANDARDS AAMA ACCA APSP ASHRAE <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | ASTM CGSB CSA DASMA ICC <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | IEEE NFPA NFRC UL <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | US-FTC WDMA <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | APPENDIX RA RECOMMENDED PROCEDURE FOR WORST-CASE TESTING OF ATMOSPHERIC VENTING SYSTEMS UNDER R402.4 OR R405 CONDITIONS \u2264 5ACH50 SECTION RA101 SCOPE SECTION RA201 GENERAL DEFINITIONS SECTION RA301 TESTING PROCEDURE <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | TABLE RA301.1(1) CAZ DEPRESSURIZATION LIMITS TABLE RA301.1(2) ACCEPTABLE DRAFT TEST CORRECTION TABLE RA301.1(3) ACCEPTABLE DRAFT TEST CORRECTION <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | APPENDIX RB (DELETED) <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | INDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Vermont Residential Building Energy Standards<\/b><\/p>\n |