{"id":166828,"date":"2024-10-19T10:07:59","date_gmt":"2024-10-19T10:07:59","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-ashrae-ngbs-700-2015\/"},"modified":"2024-10-25T02:26:50","modified_gmt":"2024-10-25T02:26:50","slug":"icc-ashrae-ngbs-700-2015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/icc-ashrae-ngbs-700-2015\/","title":{"rendered":"ICC ASHRAE NGBS 700 2015"},"content":{"rendered":"

The 2015 edition incorporates changes that better align the NGBS with the I-codes, expands the application of innovative practices and builds upon years of building and certifying to NGBS. Some of the more notable updates include: Substantial revisions to the Energy Efficiency chapter, which now has more stringent rating levels based upon whole-house energy savings that are above the 2015 International Energy Conservation Code. New criteria for measuring water usage that focus on appliance and fixture performance instead of third-party water efficiency labels. Mandatory installation of carbon monoxide alarms for all buildings, regardless of level of certification or local code. Revamped stormwater management options that encourage low-impact development practices. Greater emphasis on and recognition of multi-modal transportation options including bicycle parking, pedestrian connectivity, proximity to transit and electric-vehicle charging. New references in the Resource Efficiency chapter on innovative practices for environmental product declarations for both specific and industry-wide products. This latest edition includes everything needed to design, construct or remodel any residential project to the most current sustainable and green building criteria available – all under one roof!<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover <\/td>\n<\/tr>\n
2<\/td>\nCopyright <\/td>\n<\/tr>\n
3<\/td>\nPREFACE <\/td>\n<\/tr>\n
5<\/td>\n2015 Consensus Committee on theNational Green Building Standard\u2122 <\/td>\n<\/tr>\n
7<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
19<\/td>\nCHAPTER 1 SCOPE AND ADMINISTRATION
101 GENERAL
101.1 Title
101.2 Scope
101.3 Intent
101.4 Referenced documents
101.5 Appendices
102 CONFORMANCE
102.1 Mandatory practices
102.2 Conformance language
102.3 Documentation
102.4 Alternative compliance methods <\/td>\n<\/tr>\n
20<\/td>\n103 ADMINISTRATION
103.1 Administration <\/td>\n<\/tr>\n
21<\/td>\nCHAPTER 2 DEFINITIONS
201 GENERAL
201.1 Scope
201.2 Interchangeability
201.3 Terms defined in other documents
201.4 Terms not defined
202 DEFINITIONS <\/td>\n<\/tr>\n
31<\/td>\nCHAPTER 3 COMPLIANCE METHOD
301 GENERAL
301.1 Environmental rating levels
301.2 Awarding of points
302 GREEN SUBDIVISIONS
302.1 Site design and development
303 GREEN BUILDINGS
303.1 Green buildings <\/td>\n<\/tr>\n
32<\/td>\n304 GREEN MULTIFAMILY BUILDINGS
304.1 Multifamily buildings
305 GREEN REMODELING
305.1 Compliance
305.2 Compliance options <\/td>\n<\/tr>\n
33<\/td>\n305.3 Whole-building rating criteria <\/td>\n<\/tr>\n
34<\/td>\n305.4 Criteria for remodeled functional areas of buildings
306 GREEN ACCESSORY STRUCTURES
306.1 Applicability
306.2 Compliance <\/td>\n<\/tr>\n
35<\/td>\nCHAPTER 4 SITE DESIGN AND DEVELOPMENT
400 SITE DESIGN AND DEVELOPMENT
400.0 Intent
401 SITE SELECTION
401.0 Intent
401.1 Infill site
401.2 Greyfield site
401.3 Brownfield site
402 PROJECT TEAM, MISSION STATEMENT, AND GOALS
402.0 Intent
402.1 Team
402.2 Training
402.3 Project checklist
402.4 Development agreements <\/td>\n<\/tr>\n
36<\/td>\n403 SITE DESIGN
403.0 Intent
403.1 Natural resources
403.2 Building orientation
403.3 Slope disturbance
403.4 Soil disturbance and erosion <\/td>\n<\/tr>\n
37<\/td>\n403.5 Stormwater management
403.6 Landscape plan <\/td>\n<\/tr>\n
38<\/td>\n403.7 Wildlife habitat
403.8 Operation and maintenance plan
403.9 Existing buildings
403.10 Existing and recycled materials <\/td>\n<\/tr>\n
39<\/td>\n403.11 Demolition of existing building
403.12 Environmentally sensitive areas
404 SITE DEVELOPMENT AND CONSTRUCTION
404.0 Intent
404.1 On-site supervision and coordination
404.2 Trees and vegetation
404.3 Soil disturbance and erosion <\/td>\n<\/tr>\n
40<\/td>\n404.4 Wildlife habitat
405 INNOVATIVE PRACTICES
405.0 Intent
405.1 Driveways and parking areas <\/td>\n<\/tr>\n
41<\/td>\n405.2 Street widths
405.3 Cluster development
405.4 Planning
405.5 Wetlands
405.6 Multi-modal transportation <\/td>\n<\/tr>\n
42<\/td>\n405.7 Density
405.8 Mixed-use development
405.9 Open space
405.10 Community garden(s <\/td>\n<\/tr>\n
43<\/td>\nCHAPTER 5 LOT DESIGN, PREPARATION, AND DEVELOPMENT
500 LOT DESIGN, PREPARATION, AND DEVELOPMENT
500.0 Intent
501 LOT SELECTION
501.1 Lot
501.2 Multi-modal transportation <\/td>\n<\/tr>\n
44<\/td>\n502 PROJECT TEAM, MISSION STATEMENT, AND GOALS
502.1 Project team, mission statement, and goals
503 LOT DESIGN
503.0 Intent
503.1 Natural resources
503.2 Slope disturbance <\/td>\n<\/tr>\n
45<\/td>\n503.3 Soil disturbance and erosion
503.4 Stormwater management <\/td>\n<\/tr>\n
46<\/td>\n503.5 Landscape plan <\/td>\n<\/tr>\n
47<\/td>\n503.6 Wildlife habitat
503.7 Environmentally sensitive areas
503.8 Demolition of existing building
504 LOT CONSTRUCTION
504.0 Intent
504.1 On-site supervision and coordination
504.2 Trees and vegetation <\/td>\n<\/tr>\n
48<\/td>\n504.3 Soil disturbance and erosion implementation
505 INNOVATIVE PRACTICES
505.0 Intent
505.1 Driveways and parking areas <\/td>\n<\/tr>\n
49<\/td>\n505.2 Heat island mitigation
505.3 Density
505.4 Mixed-use development
505.5 Community garden(s
505.6 Multi-unit plug-in electric vehicle charging <\/td>\n<\/tr>\n
51<\/td>\nCHAPTER 6 RESOURCE EFFICIENCY
601 QUALITY OF CONSTRUCTION MATERIALS AND WASTE
601.0 Intent
601.1 Conditioned floor area
601.2 Material usage
601.3 Building dimensions and layouts <\/td>\n<\/tr>\n
52<\/td>\n601.4 Framing and structural plans
601.5 Prefabricated components
601.6 Stacked stories
601.7 Prefinished materials
601.8 Foundations <\/td>\n<\/tr>\n
53<\/td>\n601.9 Above grade wall systems
602 ENHANCED DURABILITY AND REDUCED MAINTENANCE
602.0 Intent
602.1 Moisture management \u2013 building envelope <\/td>\n<\/tr>\n
56<\/td>\n602.2 Roof surfaces
602.3 Roof water discharge <\/td>\n<\/tr>\n
57<\/td>\n602.4 Finished grade
603 REUSED OR SALVAGED MATERIALS
603.0 Intent
603.1 Reuse of existing building
603.2 Salvaged materials
603.3 Scrap materials
604 RECYCLED-CONTENT BUILDING MATERIALS
604.1 Recycled content <\/td>\n<\/tr>\n
58<\/td>\n605 RECYCLED CONSTRUCTION WASTE
605.0 Intent
605.1 Construction waste management plan
605.2 On-site recycling
605.3 Recycled construction materials <\/td>\n<\/tr>\n
59<\/td>\n606 RENEWABLE MATERIALS
606.0 Intent
606.1 Biobased products
606.2 Wood-based products
606.3 Manufacturing energy <\/td>\n<\/tr>\n
60<\/td>\n607 RECYCLING AND WASTE REDUCTION
607.1 Recycling and composting
607.2 Food waste disposers
608 RESOURCE-EFFICIENT MATERIALS
608.1 Resource-efficient materials
609 REGIONAL MATERIALS
609.1 Regional materials
610 LIFE CYCLE ASSESSMENT
610.1 Life cycle assessment <\/td>\n<\/tr>\n
62<\/td>\n611 INNOVATIVE PRACTICES
611.1 Manufacturer\u2019s environmental management system concepts
611.2 Sustainable products <\/td>\n<\/tr>\n
63<\/td>\n611.3 Universal design elements
611.4 Product declarations <\/td>\n<\/tr>\n
69<\/td>\nCHAPTER 7 ENERGY EFFICIENCY
701 MINIMUM ENERGY EFFICIENCY REQUIREMENTS
701.1 Mandatory requirements
701.1.1 Minimum Performance Path requirements
701.1.2 Minimum Prescriptive Path requirements
701.1.3 HERS Index Target Path requirements
701.1.4 Alternative bronze level compliance
701.2 Emerald level points
701.3 Adopting entity review
701.4 Mandatory practices <\/td>\n<\/tr>\n
70<\/td>\n701.4.1 HVAC systems
701.4.2 Duct systems
701.4.3 Insulation and air sealing <\/td>\n<\/tr>\n
73<\/td>\n701.4.4 High-efficacy lighting
701.4.5 Boiler supply piping
702 PERFORMANCE PATH
702.1 Point allocation
702.2 Energy performance levels <\/td>\n<\/tr>\n
74<\/td>\n703 PRESCRIPTIVE PATH
703.1 Mandatory practices <\/td>\n<\/tr>\n
75<\/td>\n703.2 Building envelope <\/td>\n<\/tr>\n
79<\/td>\n703.3 HVAC equipment efficiency <\/td>\n<\/tr>\n
82<\/td>\n703.4 Duct systems <\/td>\n<\/tr>\n
84<\/td>\n703.5 Water heating system <\/td>\n<\/tr>\n
86<\/td>\n703.6 Lighting and appliances
703.7 Passive solar design <\/td>\n<\/tr>\n
89<\/td>\n704 HERS INDEX TARGET PATH
704.1 HERS index target compliance
704.2 Point calculation
705 ADDITIONAL PRACTICES
705.1 Application of additional practice points
705.2 Lighting <\/td>\n<\/tr>\n
90<\/td>\n705.3 Induction cooktop
705.4 Return ducts and transfer grilles
705.5 HVAC design and installation <\/td>\n<\/tr>\n
91<\/td>\n705.6 Installation and performance verification <\/td>\n<\/tr>\n
92<\/td>\n705.7 Submetering system
706 INNOVATIVE PRACTICES
706.1 Energy consumption control <\/td>\n<\/tr>\n
93<\/td>\n706.2 Renewable energy service plan
706.3 Smart appliances and systems
706.4 Pumps <\/td>\n<\/tr>\n
94<\/td>\n706.5 On-site renewable energy system
706.6 Parking garage efficiency
706.7 Grid-interactive electric thermal storage system
706.8 Electrical vehicle charging station
706.9 Automatic demand response <\/td>\n<\/tr>\n
95<\/td>\nCHAPTER 8 WATER EFFICIENCY
801 INDOOR AND OUTDOOR WATER USE
801.0 Intent
801.1 Indoor hot water usage <\/td>\n<\/tr>\n
97<\/td>\n801.2 Water-conserving appliances
801.3 Showerheads
801.4 Lavatory faucets <\/td>\n<\/tr>\n
98<\/td>\n801.5 Water closets and urinals
801.6 Irrigation systems <\/td>\n<\/tr>\n
99<\/td>\n801.7 Rainwater collection and distribution
801.8 Sediment filters <\/td>\n<\/tr>\n
100<\/td>\n802 INNOVATIVE PRACTICES
802.1 Reclaimed, gray, or recycled water
802.2 Reclaimed water, graywater, or rainwater pre-piping
802.3 Automatic shutoff water devices
802.4 Engineered biological system or intensive bioremediation system
802.5 Recirculating humidifier
802.6 Advanced wastewater treatment system <\/td>\n<\/tr>\n
101<\/td>\nCHAPTER 9 INDOOR ENVIRONMENTAL QUALITY
901 POLLUTANT SOURCE CONTROL
901.0 Intent
901.1 Space and water heating options <\/td>\n<\/tr>\n
102<\/td>\n901.2 Solid fuel-burning appliances
901.3 Garages
901.4 Wood materials <\/td>\n<\/tr>\n
103<\/td>\n901.5 Cabinets
901.6 Carpets
901.7 Floor materials <\/td>\n<\/tr>\n
104<\/td>\n901.8 Wall coverings
901.9 Interior architectural coatings <\/td>\n<\/tr>\n
106<\/td>\n901.10 Interior adhesives and sealants <\/td>\n<\/tr>\n
107<\/td>\n901.11 Insulation
901.12 Carbon monoxide (CO) alarms
901.13 Building entrance pollutants control
901.14 Non-smoking areas
902 POLLUTANT CONTROL
902.0 Intent
902.1 Spot ventilation <\/td>\n<\/tr>\n
108<\/td>\n902.2 Building ventilation systems <\/td>\n<\/tr>\n
109<\/td>\n902.3 Radon control
902.4 HVAC system protection
902.5 Central vacuum systems
902.6 Living space contaminants
903 MOISTURE MANAGEMENT: VAPOR, RAINWATER, PLUMBING, HVAC
903.0 Intent
903.1 Plumbing <\/td>\n<\/tr>\n
110<\/td>\n903.2 Duct insulation
903.3 Relative humidity
904 INDOOR AIR QUALITY
904.0 Intent
904.1 Indoor Air Quality (IAQ) during construction
904.2 Indoor Air Quality (IAQ) post completion
905 INNOVATIVE PRACTICES
905.1 Humidity monitoring system
905.2 Kitchen exhaust <\/td>\n<\/tr>\n
113<\/td>\nCHAPTER 10 OPERATION, MAINTENANCE, AND BUILDING OWNER EDUCATION
1001 HOMEOWNER\u2019S MANUAL AND TRAINING GUIDELINES FOR ONE- AND TWO-FAMILY DWELLINGS
1001.0 Intent
1001.1 Homeowner\u2019s manual <\/td>\n<\/tr>\n
114<\/td>\n1001.2 Training of initial homeowners
1002 CONSTRUCTION, OPERATION, AND MAINTENANCE MANUALS AND TRAINING FOR MULTIFAMILY
\n BUILDINGS
1002.0 Intent <\/td>\n<\/tr>\n
115<\/td>\n1002.1 Building construction manual
1002.2 Operations manual <\/td>\n<\/tr>\n
116<\/td>\n1002.3 Maintenance manual
1002.4 Training of building owners <\/td>\n<\/tr>\n
117<\/td>\n1003 PUBLIC EDUCATION
1003.0 Intent
1003.1 Public education
1004 POST OCCUPANCY PERFORMANCE ASSESSMENT
1004.0 Intent
1004.1 Verification system
1005 INNOVATIVE PRACTICES
1005.1 (Reserved <\/td>\n<\/tr>\n
119<\/td>\nCHAPTER 11 REMODELING
11.500 LOT DESIGN, PREPARATION, AND DEVELOPMENT
11.500.0 Intent
11.501 LOT SELECTION
11.501.2 Multi-modal transportation
11.502 PROJECT TEAM, MISSION STATEMENT, AND GOALS
11.502.1 Project team, mission statement, and goals <\/td>\n<\/tr>\n
120<\/td>\n11.503 LOT DESIGN
11.503.0 Intent
11.503.1 Natural resources
11.503.2 Slope disturbance
11.503.3 Soil disturbance and erosion <\/td>\n<\/tr>\n
121<\/td>\n11.503.4 Stormwater Management
11.503.5 Landscape plan <\/td>\n<\/tr>\n
122<\/td>\n11.503.6 Wildlife habitat
11.503.7 Environmentally sensitive areas <\/td>\n<\/tr>\n
123<\/td>\n11.504 LOT CONSTRUCTION
11.504.0 Intent
11.504.1 On-site supervision and coordination
11.504.2 Trees and vegetation
11.504.3 Soil disturbance and erosion implementation <\/td>\n<\/tr>\n
124<\/td>\n11.505 INNOVATIVE PRACTICES
11.505.0 Intent
11.505.1 Driveways and parking areas
11.505.2 Heat island mitigation
11.505.3 Density <\/td>\n<\/tr>\n
125<\/td>\n11.505.4 Mixed-use development
11.505.5 Community Garden(s
11.505.6 Multi-unit plug-in electric vehicle charging
11.601 QUALITY OF CONSTRUCTION MATERIALS AND WASTE
11.601.0 Intent
11.601.1 Conditioned floor area
11.601.2 Material usage <\/td>\n<\/tr>\n
126<\/td>\n11.601.3 Building dimensions and layouts
11.601.4 Framing and structural plans
11.601.5 Prefabricated components
11.601.6 Stacked stories
11.601.7 Prefinished materials <\/td>\n<\/tr>\n
127<\/td>\n11.601.8 Foundations
11.602 ENHANCED DURABILITY AND REDUCED MAINTENANCE
11.602.0 Intent
11.602.1 Moisture management \u2013 building envelope <\/td>\n<\/tr>\n
131<\/td>\n11.602.2 Roof surfaces
11.602.3 Roof water discharge <\/td>\n<\/tr>\n
132<\/td>\n11.602.4 Finished grade
11.603 REUSED OR SALVAGED MATERIALS
11.603.0 Intent
11.603.1 Reuse of existing building
11.603.2 Salvaged materials
11.603.3 Scrap materials
11.604 RECYCLED-CONTENT BUILDING MATERIALS
11.604.1 Recycled content <\/td>\n<\/tr>\n
133<\/td>\n11.605 RECYCLED CONSTRUCTION WASTE
11.605.0 Intent
11.605.1 Hazardous waste
11.605.2 Construction waste management plan
11.605.3 On-site recycling
11.605.4 Recycled construction materials <\/td>\n<\/tr>\n
134<\/td>\n11.606 RENEWABLE MATERIALS
11.606.0 Intent
11.606.1 Biobased products
11.606.2 Wood-based products
11.606.3 Manufacturing energy <\/td>\n<\/tr>\n
135<\/td>\n11.607 RECYCLING AND WASTE REDUCTION
11.607.1 Recycling and composting
11.607.2 Food waste disposers
11.608 RESOURCE-EFFICIENT MATERIALS
11.608.1 Resource-efficient materials
11.609 REGIONAL MATERIALS
11.609.1 Regional materials
11.610 LIFE CYCLE ASSESSMENT
11.610.1 Life cycle assessment <\/td>\n<\/tr>\n
136<\/td>\n11.610.1.1 Whole-building life cycle assessment
11.610.1.2 Life cycle assessment for a product or assembly <\/td>\n<\/tr>\n
137<\/td>\n11.611 INNOVATIVE PRACTICES
11.611.1 Manufacturer\u2019s environmental management system concepts <\/td>\n<\/tr>\n
138<\/td>\n11.611.2 Sustainable products
11.611.3 Universal design elements
11.611.4 Product declarations <\/td>\n<\/tr>\n
139<\/td>\n11.701 MINIMUM ENERGY EFFICIENCY REQUIREMENTS
11.701.4 Mandatory practices
11.701.4.0 Minimum energy efficiency requirements
11.701.4.1 HVAC systems <\/td>\n<\/tr>\n
140<\/td>\n11.701.4.2 Duct systems
11.701.4.3 Insulation and air sealing <\/td>\n<\/tr>\n
143<\/td>\n11.701.4.4 High-efficacy lighting
11.701.4.5 Boiler supply piping
11.701.4.6 Fenestration specifications
11.701.4.7 Replacement fenestration
11.901 POLLUTANT SOURCE CONTROL
11.901.0 Intent
11.901.1 Space and water heating options <\/td>\n<\/tr>\n
144<\/td>\n11.901.2 Solid fuel-burning appliances <\/td>\n<\/tr>\n
145<\/td>\n11.901.3 Garages
11.901.4 Wood materials
11.901.5 Cabinets <\/td>\n<\/tr>\n
146<\/td>\n11.901.6 Carpets
11.901.7 Floor materials
11.901.8 Wall coverings
11.901.9 Interior architectural coatings <\/td>\n<\/tr>\n
149<\/td>\n11.901.10 Interior Adhesives and sealants <\/td>\n<\/tr>\n
150<\/td>\n11.901.11 Insulation
11.901.12 Carbon monoxide (CO) alarms
11.901.13 Building entrance pollutants control
11.901.14 Non-smoking areas
11.901.15 Lead-safe work practices
11.902 POLLUTANT CONTROL
11.902.0 Intent
11.902.1 Spot ventilation <\/td>\n<\/tr>\n
151<\/td>\n11.902.2 Building ventilation systems <\/td>\n<\/tr>\n
152<\/td>\n11.902.3 Radon control
11.902.4 HVAC system protection
11.902.5 Central vacuum systems
11.902.6 Living space contaminants
11.903 MOISTURE MANAGEMENT: VAPOR, RAINWATER, PLUMBING, HVAC
11.903.0 Intent
11.903.1 Plumbing <\/td>\n<\/tr>\n
153<\/td>\n11.903.2 Duct insulation
11.903.3 Relative humidity
11.904 INDOOR AIR QUALITY
11.904.0 Intent
11.904.1 Indoor Air Quality (IAQ) during construction
11.904.2 Indoor Air Quality (IAQ) post completion
11.905 INNOVATIVE PRACTICES
11.905.1 Humidity monitoring system
11.905.2 Kitchen exhaust <\/td>\n<\/tr>\n
154<\/td>\n11.1001 HOMEOWNER\u2019S MANUAL AND TRAINING GUIDELINES FOR ONE- AND TWO-FAMILY DWELLINGS
\n
11.1001.0 Intent
11.1001.1 Homeowner\u2019s manual <\/td>\n<\/tr>\n
155<\/td>\n11.1001.2 Training of initial building owners
11.1002 CONSTRUCTION, OPERATION, AND MAINTENANCE MANUALS AND TRAINING FOR
\n MULTIFAMILY BUILDINGS
11.1002.0 Intent <\/td>\n<\/tr>\n
156<\/td>\n11.1002.1 Building construction manual
11.1002.2 Operations manual <\/td>\n<\/tr>\n
157<\/td>\n11.1002.3 Maintenance manual
11.1002.4 Training of building owners <\/td>\n<\/tr>\n
158<\/td>\n11.1003 PUBLIC EDUCATION
11.1003.0 Intent
11.1003.1 Public Education
11.1005 INNOVATIVE PRACTICES <\/td>\n<\/tr>\n
159<\/td>\nCHAPTER 12 REMODELING OF FUNCTIONAL AREAS
12.0 REMODELING OF FUNCTIONAL AREAS
12.0 Intent
12.0.1 Applicability
12.1 GENERAL
12.1.601.2 Material usage
12.1.602.1.7.1 Moisture control measures <\/td>\n<\/tr>\n
160<\/td>\n12.1.602.1.7.2 Moisture content
12.1.602.1.11 Tile backing materials
12.1(A) Product or material selection
12.1(A).601.7 Prefinished materials
12.1(A).603.2 Reused and salvaged materials
12.1(A).604.1 Recycled content
12.1(A).605.1 Construction waste management plan
12.1(A).606.1 Biobased products <\/td>\n<\/tr>\n
161<\/td>\n12.1(A).606.2 Wood-based products
12.1(A).608.1 Resource-efficient materials
12.1(A).609.1 Regional materials
12.1(A).610.1 Life cycle assessment <\/td>\n<\/tr>\n
162<\/td>\n12.1(A).610.1.1 Functional area life cycle assessment
12.1(A).610.1.2 Life cycle assessment for a product or assembly <\/td>\n<\/tr>\n
163<\/td>\n12.1(A).611.1 Manufacturer\u2019s environmental management system concepts
12.1(A).611.2 Sustainable products <\/td>\n<\/tr>\n
164<\/td>\n12.1.605.0 Hazardous materials and waste
12.1.701.4.0 Minimum Energy Efficiency Requirements
12.1.701.4.1.1 HVAC system sizing
12.1.701.4.2.1 Duct air sealing
12.1.701.4.2.2 Ducts and plenums
12.1.701.4.2.3 Duct system sizing
12.1.701.4.3.1 Building thermal envelope air sealing <\/td>\n<\/tr>\n
165<\/td>\n12.1.701.4.3.2 Air sealing and insulation <\/td>\n<\/tr>\n
167<\/td>\n12.1.701.4.3.4 Fenestration air leakage
12.1.701.4.3.5 Recessed lighting
12.1.701.4.4 High-efficacy lighting
12.1.701.4.5 Boiler supply piping
12.1.701.4.6 Fenestration specifications
12.1.701.4.7 Replacement fenestration
12.1.703.6.2 Appliances
12.1.901.1.4 Gas-fired equipment
12.1.901.2.1 Solid fuel-burning appliances <\/td>\n<\/tr>\n
168<\/td>\n12.1.901.3 Attached garages
12.1.901.4 Wood materials
12.1.901.5 Cabinets
12.1.901.6 Carpets
12.1.901.7 Floor materials <\/td>\n<\/tr>\n
169<\/td>\n12.1.901.8 Interior wall coverings
12.1.901.9 Architectural coatings <\/td>\n<\/tr>\n
170<\/td>\n12.1.901.10 Adhesives and sealants <\/td>\n<\/tr>\n
172<\/td>\n12.1.901.11 Insulation
12.1.901.15 Lead-safe work practices
12.1.902.1.1 Spot ventilation
12.1.902.4 HVAC system protection
12.1.903.2 Duct insulation
12.2 KITCHEN REMODELS
12.2.0 Applicability
12.2.607.1 Recycling and composting
12.2.607.2 Food waste disposers
12.3.801.4.1 Faucets <\/td>\n<\/tr>\n
173<\/td>\n12.3 BATHROOM REMODELS
12.3.0 Applicability
12.3.611.3 Universal design elements
12.3.801.3 Showerheads
12.3.801.4.1 Faucets
12.3.801.5 Water closets
12.4 BASEMENT REMODELS
12.4.0 Applicability
12.4.1 Moisture inspection
12.4.2 Kitchen
12.4.3 Bathroom
12.4.902.3 Radon control <\/td>\n<\/tr>\n
174<\/td>\n12.5 CONVERSION OF PREVIOUSLY UNCONDITIONED SPACE TO CONDITIONED SPACE
12.5.0 Applicability
12.5.1 Moisture inspection
12.5.2 Kitchen
12.5.3 Bathroom
12.5.4 Knee walls
12.6 ADDITIONS
12.6.0 Applicability
12.6.1 Kitchen
12.6.2 Bathroom
12.6.503.5 Landscape plan
12.6.602.1.1.1 Capillary break
12.6.602.1.3.1 Exterior drain tile <\/td>\n<\/tr>\n
175<\/td>\n12.6.602.1.4.1 Crawlspace
12.6.602.1.8 Water-resistive barrier
12.6.602.1.9 Flashing
12.6.602.1.13 Ice barrier
12.6.602.1.14 Architectural features <\/td>\n<\/tr>\n
176<\/td>\n12.6.602.4.1 Finished grade
12.6.902.3 Radon control <\/td>\n<\/tr>\n
177<\/td>\nCHAPTER 13 REFERENCED DOCUMENTS
1301 GENERAL
1302 REFERENCED DOCUMENTS <\/td>\n<\/tr>\n
193<\/td>\nAPPENDIX A DUCTED GARAGE EXHAUST FAN SIZING CRITERIA <\/td>\n<\/tr>\n
195<\/td>\nAPPENDIX B WHOLE BUILDING VENTILATION SYSTEM SPECIFICATIONS <\/td>\n<\/tr>\n
199<\/td>\nAPPENDIX C CLIMATE ZONES <\/td>\n<\/tr>\n
213<\/td>\nAPPENDIX D EXAMPLES OF THIRD-PARTY PROGRAMS FOR INDOOR ENVIRONMENTAL QUALITY <\/td>\n<\/tr>\n
215<\/td>\nAPPENDIX E ACCESSORY STRUCTURES <\/td>\n<\/tr>\n
217<\/td>\nINDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASHRAE\/ICC 700-2015 National Green Building Standard<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASHRAE<\/b><\/a><\/td>\n2015<\/td>\n220<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":166830,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2719],"product_tag":[],"class_list":{"0":"post-166828","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ashrae","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/166828","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/166830"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=166828"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=166828"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=166828"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}