{"id":416975,"date":"2024-10-20T06:13:40","date_gmt":"2024-10-20T06:13:40","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60349-42013-2\/"},"modified":"2024-10-26T11:34:35","modified_gmt":"2024-10-26T11:34:35","slug":"bs-en-60349-42013-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60349-42013-2\/","title":{"rendered":"BS EN 60349-4:2013"},"content":{"rendered":"

This part of IEC 60349 applies to converter-fed permanent magnet synchronous motors or generators (machines) forming part of the equipment of electrically propelled rail and road vehicles.<\/p>\n

This standard is derived from IEC 60349-2 changing the subject to permanent magnet synchronous machines.<\/p>\n

The object of this part is to enable the performance of a machine to be confirmed by tests and to provide a basis for assessment of its suitability for a specified duty and for comparison with other machines.<\/p>\n

Where further testing is to be undertaken in accordance with a combined test, it may be preferable, that some type and investigation tests be carried out on the combined test bed, to avoid duplication.<\/p>\n

Particular attention is drawn to the need for collaboration between the designers of the machine and its associated converter as detailed in 5.1.<\/p>\n

\n

NOTE 1 This part also applies to machines installed on trailers hauled by powered vehicles.<\/p>\n<\/blockquote>\n

\n

NOTE 2 The basic requirements of this part may be applied to machines for special purpose vehicles such as mine locomotives but this part does not cover flameproof or other special features that may be required.<\/p>\n<\/blockquote>\n

\n

NOTE 3 It is not intended that this part should apply to machines on small road vehicles, such as battery-fed delivery vehicles, factory trucks, etc. This part also does not apply to minor machines such as windscreen wiper motors, etc. that may be used on all types of vehicles.<\/p>\n<\/blockquote>\n

\n

NOTE 4 Industrial type machines complying with IEC 60034 may be suitable for some auxiliary drives, provided that it is demonstrated that operation on a converter supply will meet the requirements of the particular application.<\/p>\n<\/blockquote>\n

The electrical input to motors covered by this part is be from an electronic converter. Generators may be connected to a rectifier or a converter.<\/p>\n

The machines covered by this part are classified as follows:<\/p>\n

    \n
  1. \n

    Traction motors<\/p>\n

    Motors for propelling rail or road vehicles.<\/p>\n<\/li>\n

  2. \n

    Main generators<\/p>\n

    Generators for supplying power to traction motors on the same vehicle or train.<\/p>\n<\/li>\n

  3. \n

    Auxiliary motors not covered by IEC 60034<\/p>\n

    Motors for driving compressors, fans, auxiliary generators or other auxiliary machines.<\/p>\n<\/li>\n

  4. \n

    Auxiliary generators not covered by IEC 60034<\/p>\n

    Generators for supplying power for auxiliary services such as air conditioning, heating, lighting and battery charging, etc.<\/p>\n<\/li>\n<\/ol>\n

    PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
    PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
    6<\/td>\nEnglish
    CONTENTS <\/td>\n<\/tr>\n
    8<\/td>\n1 Scope and object <\/td>\n<\/tr>\n
    9<\/td>\n2 Normative references
    3 Terms and definitions <\/td>\n<\/tr>\n
    12<\/td>\n4 Environmental conditions
    5 Characteristics
    5.1 Exchange of information <\/td>\n<\/tr>\n
    13<\/td>\n5.2 Special characteristic of a driven permanent magnet machine
    5.3 Reference temperature
    5.4 Specified characteristics
    5.5 Declared characteristics
    5.6 Efficiency characteristics
    5.7 Traction motor characteristics <\/td>\n<\/tr>\n
    14<\/td>\n5.8 Main generator characteristics
    5.9 Auxiliary motor characteristics
    5.10 Auxiliary generator characteristics <\/td>\n<\/tr>\n
    15<\/td>\n6 Marking
    6.1 Nameplate
    6.2 Terminal and lead marking
    7 Test categories
    7.1 General
    7.2 Type tests
    7.2.1 General <\/td>\n<\/tr>\n
    16<\/td>\n7.2.2 Type tests on converter supply
    7.3 Reduced type test
    7.3.1 General
    7.3.2 Repeat the type test temperature rise test with converter
    7.3.3 Repeat a temperature rise test with converter with different load
    7.3.4 Repeat a temperature rise test with sinusoidal supply <\/td>\n<\/tr>\n
    17<\/td>\n7.3.5 Repeat a temperature rise test in generating mode with a passive load
    7.4 Routine tests
    7.5 Investigation tests
    7.6 Summary of tests
    Tables
    Table 1 \u2013 Summary of tests <\/td>\n<\/tr>\n
    18<\/td>\n8 Type tests
    8.1 Temperature-rise tests
    8.1.1 General
    8.1.2 Cooling during rating tests
    8.1.3 Measurement of temperature
    8.1.4 Judgement of results
    8.1.5 Limits of temperature rise <\/td>\n<\/tr>\n
    19<\/td>\n8.1.6 Short-time overload test
    8.2 Characteristic tests and tolerances
    8.2.1 General
    Table 2 \u2013 Limits of temperature rise for continuous and other ratings <\/td>\n<\/tr>\n
    20<\/td>\n8.2.2 Tolerances
    Figures
    Figure 1 \u2013 Inherent characteristic generator <\/td>\n<\/tr>\n
    21<\/td>\n8.3 Overspeed test
    8.4 Vibration tests
    8.5 Noise measurements (optional) <\/td>\n<\/tr>\n
    22<\/td>\n9 Routine tests
    9.1 General
    9.2 Characteristic tests and tolerances
    9.2.1 General
    9.2.2 No-load tests
    Figure 2 \u2013 Open terminal <\/td>\n<\/tr>\n
    23<\/td>\n9.2.3 Current-load tests
    Figure 3 \u2013 Sinusoidal supply
    Figure 4 \u2013 Converter supply
    Figure 5 \u2013 Converter supply with cut off <\/td>\n<\/tr>\n
    24<\/td>\n9.3 Overspeed tests
    Figure 6 \u2013 Short-circuit
    Figure 7 \u2013 Sinusoidal supply
    Figure 8 \u2013 Converter supply <\/td>\n<\/tr>\n
    25<\/td>\n9.4 Dielectric tests
    Table 3 \u2013 Dielectric test voltages <\/td>\n<\/tr>\n
    26<\/td>\n9.5 Vibration tests (imbalance)
    10 Investigation tests
    10.1 Measurement of cogging torque
    10.2 Temperature rise test of the machine in high speed with open terminals
    10.3 Temperature coefficient measurement of the induced voltage <\/td>\n<\/tr>\n
    27<\/td>\nAnnex\u00a0A (normative)Measurement of temperature <\/td>\n<\/tr>\n
    30<\/td>\nAnnex\u00a0B (normative)Conventional values of traction motor transmission losses
    Figure B.1 \u2013 Conventional values of traction motor transmission losses <\/td>\n<\/tr>\n
    31<\/td>\nAnnex\u00a0C (informative)Noise measurement and limits <\/td>\n<\/tr>\n
    33<\/td>\nTable C.1 \u2013 Corrections <\/td>\n<\/tr>\n
    36<\/td>\nTable C.2 \u2013 Corrections <\/td>\n<\/tr>\n
    37<\/td>\nFigure C.1 \u2013 Limiting mean sound power level for airborne noise emitted by traction machines
    Table C.3 \u2013 Correction for pure tones <\/td>\n<\/tr>\n
    38<\/td>\nFigure C.2 \u2013 Location of measuring points and prescribed paths for horizontal machines <\/td>\n<\/tr>\n
    39<\/td>\nFigure C.3 \u2013 Location of measuring points and prescribed paths for vertical machines <\/td>\n<\/tr>\n
    40<\/td>\nAnnex\u00a0D (normative)Supply voltages of traction systems <\/td>\n<\/tr>\n
    41<\/td>\nAnnex\u00a0E (normative)Agreement between user and manufacturer <\/td>\n<\/tr>\n
    42<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

    Electric traction. Rotating electrical machines for rail and road vehicles – Permanent magnet synchronous electrical machines connected to an electronic converter<\/b><\/p>\n\n\n\n\n
    Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
    BSI<\/b><\/a><\/td>\n2013<\/td>\n44<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":416983,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[775,2641],"product_tag":[],"class_list":{"0":"post-416975","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-45-060-01","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/416975","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/416983"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=416975"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=416975"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=416975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}