{"id":72182,"date":"2024-10-17T16:14:27","date_gmt":"2024-10-17T16:14:27","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/va-vamc-2009\/"},"modified":"2024-10-24T19:04:18","modified_gmt":"2024-10-24T19:04:18","slug":"va-vamc-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/va\/va-vamc-2009\/","title":{"rendered":"VA VAMC 2009"},"content":{"rendered":"

This is a fully integrated code based on the 2009 International Mechanical Code\u00ae.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n2009 VIRGINIA MECHANICAL CODE <\/td>\n<\/tr>\n
2<\/td>\n2009 VIRGINIA MECHANICAL CODE EXCERPTS FROM THE VIRGINIA CONSTRUCTION CODE FOR MECHANICAL WORK TITLE PAGE <\/td>\n<\/tr>\n
3<\/td>\nCOPYRIGHT <\/td>\n<\/tr>\n
4<\/td>\nPREFACE <\/td>\n<\/tr>\n
6<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
10<\/td>\nCHAPTER 1 – ADMINISTRATION
SECTION 101 GENERAL
SECTION 102 PURPOSE AND SCOPE
SECTION 103 APPLICATION OF CODE <\/td>\n<\/tr>\n
12<\/td>\nSECTION 104 ENFORCEMENT, GENERALLY <\/td>\n<\/tr>\n
13<\/td>\nSECTION 105 LOCAL BUILDING DEPARTMENT <\/td>\n<\/tr>\n
14<\/td>\nSECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL
SECTION 107 FEES
SECTION 108 APPLICATION FOR PERMIT <\/td>\n<\/tr>\n
16<\/td>\nSECTION 109 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n
17<\/td>\nSECTION 110 PERMITS <\/td>\n<\/tr>\n
18<\/td>\nSECTION 111 RDP SERVICES
SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT <\/td>\n<\/tr>\n
19<\/td>\nSECTION 113 INSPECTIONS <\/td>\n<\/tr>\n
20<\/td>\nSECTION 114 STOP WORK ORDERS
SECTION 115 VIOLATIONS <\/td>\n<\/tr>\n
21<\/td>\nSECTION 116 CERTIFICATES OF OCCUPANCY
SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION <\/td>\n<\/tr>\n
22<\/td>\nSECTION 118 BUILDINGS AND STRUCTURES BECOMING UNSAFE DURING CONSTRUCTION
SECTION 119 APPEALS <\/td>\n<\/tr>\n
26<\/td>\nCHAPTER 2 – DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n
36<\/td>\nCHAPTER 3 – GENERAL REGULATIONS
SECTION 301 GENERAL <\/td>\n<\/tr>\n
37<\/td>\nSECTION 302 PROTECTION OF STRUCTURE <\/td>\n<\/tr>\n
38<\/td>\nSECTION 303 EQUIPMENT AND APPLIANCE LOCATION
SECTION 304 INSTALLATION <\/td>\n<\/tr>\n
39<\/td>\nSECTION 305 PIPING SUPPORT <\/td>\n<\/tr>\n
40<\/td>\nTABLE 305.4 PIPING SUPPORT SPACING
SECTION 306 ACCESS AND SERVICE SPACE <\/td>\n<\/tr>\n
41<\/td>\nSECTION 307 CONDENSATE DISPOSAL <\/td>\n<\/tr>\n
42<\/td>\nTABLE 307.2.2 CONDENSATE DRAIN SIZING
SECTION 308 CLEARANCE REDUCTION <\/td>\n<\/tr>\n
43<\/td>\nTABLE 308.6 CLEARANCE REDUCTION METHODS <\/td>\n<\/tr>\n
44<\/td>\nSECTION 309 TEMPERATURE CONTROL
SECTION 310 EXPLOSION CONTROL
SECTION 311 SMOKE AND HEAT VENTS
SECTION 312 HEATING AND COOLING LOAD CALCULATIONS <\/td>\n<\/tr>\n
46<\/td>\nCHAPTER 4 – VENTILATION
SECTION 401 GENERAL
TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR IN TAKE OPENINGS
SECTION 402 NATURAL VENTILATION <\/td>\n<\/tr>\n
47<\/td>\nSECTION 403 MECHANICAL VENTILATION
EQUATION 4-1 <\/td>\n<\/tr>\n
48<\/td>\nTABLE 403.3 MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n
49<\/td>\nTABLE 403.3\u2014continued MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n
50<\/td>\nTABLE 403.3\u2014continued MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n
51<\/td>\nTABLE 403.3.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS
EQUATION 4-2
EQUATION 4-3
EQUATION 4-4
EQUATION 4-5
TABLE 403.3.2.3.2 SYSTEM VENTILATION EFFICIENCY
EQUATION 4-6
EQUATION 4-7 <\/td>\n<\/tr>\n
52<\/td>\nEQUATION 4-8
SECTION 404 ENCLOSED PARKING GARAGES
SECTION 405 SYSTEMS CONTROL
SECTION 406 VENTILATION OF UNINHABITED SPACES <\/td>\n<\/tr>\n
54<\/td>\nCHAPTER 5 – EXHAUST SYSTEMS
SECTION 501 GENERAL
SECTION 502 REQUIRED SYSTEMS <\/td>\n<\/tr>\n
55<\/td>\nEQUATION 5-1 <\/td>\n<\/tr>\n
61<\/td>\nSECTION 503 MOTORS AND FANS
SECTION 504 CLOTHES DRYER EXHAUST <\/td>\n<\/tr>\n
62<\/td>\nTABLE 504.6.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH <\/td>\n<\/tr>\n
63<\/td>\nSECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT
SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT <\/td>\n<\/tr>\n
67<\/td>\nSECTION 507 COMMERCIAL KITCHEN HOODS <\/td>\n<\/tr>\n
68<\/td>\nTABLE 507.11 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE <\/td>\n<\/tr>\n
69<\/td>\nSECTION 508 COMMERCIAL KITCHEN MAKEUP AIR
SECTION 509 FIRE SUPPRESSION SYSTEMS
SECTION 510 HAZARDOUS EXHAUST SYSTEMS <\/td>\n<\/tr>\n
71<\/td>\nTABLE 510.8 MINIMUM DUCT THICKNESS
TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES
SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS <\/td>\n<\/tr>\n
72<\/td>\nTABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS
SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS <\/td>\n<\/tr>\n
73<\/td>\nSECTION 513 SMOKE CONTROL SYSTEMS <\/td>\n<\/tr>\n
74<\/td>\nEQUATION 5-2
EQUATION 5-3 <\/td>\n<\/tr>\n
75<\/td>\nEQUATION 5-4 <\/td>\n<\/tr>\n
76<\/td>\nSECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS <\/td>\n<\/tr>\n
78<\/td>\nCHAPTER 6 – DUCT SYSTEMS
SECTION 601 GENERAL
SECTION 602 PLENUMS <\/td>\n<\/tr>\n
80<\/td>\nSECTION 603 DUCT CONSTRUCTION AND INSTALLATION
TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS <\/td>\n<\/tr>\n
81<\/td>\nSECTION 604 INSULATION <\/td>\n<\/tr>\n
82<\/td>\nSECTION 605 AIR FILTERS
SECTION 606 SMOKE DETECTION SYSTEMS CONTROL <\/td>\n<\/tr>\n
83<\/td>\nSECTION 607 DUCT AND TRANSFER OPENINGS <\/td>\n<\/tr>\n
84<\/td>\nTABLE 607.3.2.1 FIRE DAMPER RATING <\/td>\n<\/tr>\n
88<\/td>\nCHAPTER 7 – COMBUSTION AIR
SECTION 701 GENERAL <\/td>\n<\/tr>\n
90<\/td>\nCHAPTER 8 – CHIMNEYS AND VENTS
SECTION 801 GENERAL <\/td>\n<\/tr>\n
91<\/td>\nSECTION 802 VENTS
TABLE 802.2 VENT APPLICATION <\/td>\n<\/tr>\n
92<\/td>\nSECTION 803 CONNECTORS
TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES
TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES <\/td>\n<\/tr>\n
93<\/td>\nTABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES
TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES
SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS <\/td>\n<\/tr>\n
94<\/td>\nSECTION 805 FACTORY-BUILT CHIMNEYS <\/td>\n<\/tr>\n
95<\/td>\nSECTION 806 METAL CHIMNEYS <\/td>\n<\/tr>\n
96<\/td>\nCHAPTER 9 – SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT
SECTION 901 GENERAL
SECTION 902 MASONRY FIREPLACES
SECTION 903 FACTORY-BUILT FIREPLACES
SECTION 904 PELLET FUEL-BURNING APPLIANCES
SECTION 905 FIREPLACE STOVES AND ROOM HEATERS
SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES
SECTION 907 INCINERATORS AND CREMATORIES
SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS <\/td>\n<\/tr>\n
97<\/td>\nSECTION 909 VENTED WALL FURNACES
SECTION 910 FLOOR FURNACES
SECTION 911 DUCT FURNACES
SECTION 912 INFRARED RADIANT HEATERS
SECTION 913 CLOTHES DRYERS <\/td>\n<\/tr>\n
98<\/td>\nSECTION 914 SAUNA HEATERS
SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES
SECTION 916 POOL AND SPA HEATERS
SECTION 917 COOKING APPLIANCES
SECTION 918 FORCED-AIR WARM-AIR FURNACES <\/td>\n<\/tr>\n
99<\/td>\nSECTION 919 CONVERSION BURNERS
SECTION 920 UNIT HEATERS <\/td>\n<\/tr>\n
100<\/td>\nSECTION 921 VENTED ROOM HEATERS
SECTION 922 KEROSENE AND OIL-FIRED STOVES
SECTION 923 SMALL CERAMIC KILNS
SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS
SECTION 925 MASONRY HEATERS
SECTION 926 GASEOUS HYDROGEN SYSTEMS
SECTION 927 HEAT RECOVERY VENTILATORS <\/td>\n<\/tr>\n
102<\/td>\nCHAPTER 10 – BOILERS, WATER HEATERS AND PRESSURE VESSELS
SECTION 1001 GENERAL
SECTION 1002 WATER HEATERS
SECTION 1003 PRESSURE VESSELS
SECTION 1004 BOILERS <\/td>\n<\/tr>\n
103<\/td>\nSECTION 1005 BOILER CONNECTIONS
SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS
SECTION 1007 BOILER LOW-WATER CUTOFF <\/td>\n<\/tr>\n
104<\/td>\nSECTION 1008 STEAM BLOWOFF VALVE
SECTION 1009 HOT WATER BOILER EXPANSION TANK
EQUATION 10-1
SECTION 1010 GAUGES
SECTION 1011 TESTS <\/td>\n<\/tr>\n
106<\/td>\nCHAPTER 11 – REFRIGERATION
SECTION 1101 GENERAL
SECTION 1102 SYSTEM REQUIREMENTS <\/td>\n<\/tr>\n
107<\/td>\nSECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION
SECTION 1104 SYSTEM APPLICATION REQUIREMENTS <\/td>\n<\/tr>\n
108<\/td>\nTABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n
109<\/td>\nTABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n
110<\/td>\nTABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n
111<\/td>\nTABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n
112<\/td>\nTABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS <\/td>\n<\/tr>\n
113<\/td>\nSECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS
EQUATION 11-1 <\/td>\n<\/tr>\n
114<\/td>\nEQUATION 11-2
SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS
SECTION 1107 REFRIGERANT PIPING <\/td>\n<\/tr>\n
116<\/td>\nSECTION 1108 FIELD TEST
SECTION 1109 PERIODIC TESTING <\/td>\n<\/tr>\n
118<\/td>\nCHAPTER 12 – HYDRONIC PIPING
SECTION 1201 GENERAL
SECTION 1202 MATERIAL
TABLE 1202.4 HYDRONIC PIPE
TABLE 1202.4\u2014continued HYDRONIC PIPE
TABLE 1202.5 HYDRONIC PIPE FITTINGS <\/td>\n<\/tr>\n
119<\/td>\nSECTION 1203 JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n
120<\/td>\nSECTION 1204 PIPE INSULATION <\/td>\n<\/tr>\n
121<\/td>\nSECTION 1205 VALVES
SECTION 1206 PIPING INSTALLATION
SECTION 1207 TRANSFER FLUID
SECTION 1208 TESTS <\/td>\n<\/tr>\n
122<\/td>\nSECTION 1209 EMBEDDED PIPING <\/td>\n<\/tr>\n
124<\/td>\nCHAPTER 13 – FUEL OIL PIPING AND STORAGE
SECTION 1301 GENERAL
SECTION 1302 MATERIAL
TABLE 1302.3 FUEL OIL PIPING
SECTION 1303 JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n
125<\/td>\nSECTION 1304 PIPING SUPPORT
SECTION 1305 FUEL OIL SYSTEM INSTALLATION <\/td>\n<\/tr>\n
126<\/td>\nSECTION 1306 OIL GAUGING
SECTION 1307 FUEL OIL VALVES
SECTION 1308 TESTING <\/td>\n<\/tr>\n
128<\/td>\nCHAPTER 14 – SOLAR SYSTEMS
SECTION 1401 GENERAL
SECTION 1402 INSTALLATION <\/td>\n<\/tr>\n
129<\/td>\nSECTION 1403 HEAT TRANSFER FLUIDS
SECTION 1404 MATERIALS <\/td>\n<\/tr>\n
130<\/td>\nCHAPTER 15 – REFERENCED STANDARDS
ACCA
AHRI
ANSI
ASHRAE
ASME <\/td>\n<\/tr>\n
131<\/td>\nASSE
ASTM <\/td>\n<\/tr>\n
132<\/td>\nAWS <\/td>\n<\/tr>\n
133<\/td>\nAWWA
CSA
DOL
FS
ICC <\/td>\n<\/tr>\n
134<\/td>\nIIAR
MSS
NAIMA
NFPA <\/td>\n<\/tr>\n
135<\/td>\nSMACNA
UL <\/td>\n<\/tr>\n
138<\/td>\nAPPENDIX A COMBUSTION AIR OPENINGS AND CHIMNEY CONNECTOR PASS-THROUGHS
FIGURE A-1 ALL AIR FROM INSIDE THE BUILDING
FIGURE A-2 ALL AIR FROM OUTDOORS\u2014INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC <\/td>\n<\/tr>\n
139<\/td>\nFIGURE A-3 ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC
FIGURE A-4 ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS <\/td>\n<\/tr>\n
140<\/td>\nFIGURE A-5 CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n
141<\/td>\nFIGURE A-5\u2014continued CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n
142<\/td>\nAPPENDIX B RECOMMENDED PERMIT FEE SCHEDULE
B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS
B102 FEE FOR REINSPECTION
B103 TEMPORARY OPERATION INSPECTION FEE
B104 SELF-CONTAINED UNITS LESS THAN 2 TONS <\/td>\n<\/tr>\n
144<\/td>\nINDEX <\/td>\n<\/tr>\n
148<\/td>\nICC-ES PMG PROGRAM <\/td>\n<\/tr>\n
149<\/td>\nINCREASE YOUR CODE KNOWLEDGE <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Virginia Mechanical Code<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
VA<\/b><\/a><\/td>\n2009<\/td>\n149<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":72183,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2718],"product_tag":[],"class_list":{"0":"post-72182","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-va","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/72182","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/72183"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=72182"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=72182"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=72182"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}