{"id":72182,"date":"2024-10-17T16:14:27","date_gmt":"2024-10-17T16:14:27","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/va-vamc-2009\/"},"modified":"2024-10-24T19:04:18","modified_gmt":"2024-10-24T19:04:18","slug":"va-vamc-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/va\/va-vamc-2009\/","title":{"rendered":"VA VAMC 2009"},"content":{"rendered":"
This is a fully integrated code based on the 2009 International Mechanical Code\u00ae.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 2009 VIRGINIA MECHANICAL CODE <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | 2009 VIRGINIA MECHANICAL CODE EXCERPTS FROM THE VIRGINIA CONSTRUCTION CODE FOR MECHANICAL WORK TITLE PAGE <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | COPYRIGHT <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | PREFACE <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | CHAPTER 1 – ADMINISTRATION SECTION 101 GENERAL SECTION 102 PURPOSE AND SCOPE SECTION 103 APPLICATION OF CODE <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | SECTION 104 ENFORCEMENT, GENERALLY <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | SECTION 105 LOCAL BUILDING DEPARTMENT <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | SECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL SECTION 107 FEES SECTION 108 APPLICATION FOR PERMIT <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | SECTION 109 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | SECTION 110 PERMITS <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | SECTION 111 RDP SERVICES SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | SECTION 113 INSPECTIONS <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | SECTION 114 STOP WORK ORDERS SECTION 115 VIOLATIONS <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | SECTION 116 CERTIFICATES OF OCCUPANCY SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | SECTION 118 BUILDINGS AND STRUCTURES BECOMING UNSAFE DURING CONSTRUCTION SECTION 119 APPEALS <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | CHAPTER 2 – DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | CHAPTER 3 – GENERAL REGULATIONS SECTION 301 GENERAL <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | SECTION 302 PROTECTION OF STRUCTURE <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | SECTION 303 EQUIPMENT AND APPLIANCE LOCATION SECTION 304 INSTALLATION <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | SECTION 305 PIPING SUPPORT <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | TABLE 305.4 PIPING SUPPORT SPACING SECTION 306 ACCESS AND SERVICE SPACE <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | SECTION 307 CONDENSATE DISPOSAL <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | TABLE 307.2.2 CONDENSATE DRAIN SIZING SECTION 308 CLEARANCE REDUCTION <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | TABLE 308.6 CLEARANCE REDUCTION METHODS <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | SECTION 309 TEMPERATURE CONTROL SECTION 310 EXPLOSION CONTROL SECTION 311 SMOKE AND HEAT VENTS SECTION 312 HEATING AND COOLING LOAD CALCULATIONS <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | CHAPTER 4 – VENTILATION SECTION 401 GENERAL TABLE 401.5 OPENING SIZES IN LOUVERS, GRILLES AND SCREENS PROTECTING AIR IN TAKE OPENINGS SECTION 402 NATURAL VENTILATION <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | SECTION 403 MECHANICAL VENTILATION EQUATION 4-1 <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | TABLE 403.3 MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | TABLE 403.3\u2014continued MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | TABLE 403.3\u2014continued MINIMUM VENTILATION RATES <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | TABLE 403.3.1.2 ZONE AIR DISTRIBUTION EFFECTIVENESS EQUATION 4-2 EQUATION 4-3 EQUATION 4-4 EQUATION 4-5 TABLE 403.3.2.3.2 SYSTEM VENTILATION EFFICIENCY EQUATION 4-6 EQUATION 4-7 <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | EQUATION 4-8 SECTION 404 ENCLOSED PARKING GARAGES SECTION 405 SYSTEMS CONTROL SECTION 406 VENTILATION OF UNINHABITED SPACES <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | CHAPTER 5 – EXHAUST SYSTEMS SECTION 501 GENERAL SECTION 502 REQUIRED SYSTEMS <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | EQUATION 5-1 <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | SECTION 503 MOTORS AND FANS SECTION 504 CLOTHES DRYER EXHAUST <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | TABLE 504.6.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | SECTION 505 DOMESTIC KITCHEN EXHAUST EQUIPMENT SECTION 506 COMMERCIAL KITCHEN HOOD VENTILATION SYSTEM DUCTS AND EXHAUST EQUIPMENT <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | SECTION 507 COMMERCIAL KITCHEN HOODS <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | TABLE 507.11 MINIMUM DISTANCE BETWEEN THE LOWEST EDGE OF A GREASE FILTER AND THE COOKING SURFACE OR THE HEATING SURFACE <\/td>\n<\/tr>\n | ||||||
69<\/td>\n | SECTION 508 COMMERCIAL KITCHEN MAKEUP AIR SECTION 509 FIRE SUPPRESSION SYSTEMS SECTION 510 HAZARDOUS EXHAUST SYSTEMS <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | TABLE 510.8 MINIMUM DUCT THICKNESS TABLE 510.8.2 CLEARANCE TO COMBUSTIBLES SECTION 511 DUST, STOCK AND REFUSE CONVEYING SYSTEMS <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | TABLE 511.2 CONSTRUCTION, CLEARANCE AND TERMINATION REQUIREMENTS FOR SINGLE-WALL METAL CHIMNEYS SECTION 512 SUBSLAB SOIL EXHAUST SYSTEMS <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | SECTION 513 SMOKE CONTROL SYSTEMS <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | EQUATION 5-2 EQUATION 5-3 <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | EQUATION 5-4 <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | SECTION 514 ENERGY RECOVERY VENTILATION SYSTEMS <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | CHAPTER 6 – DUCT SYSTEMS SECTION 601 GENERAL SECTION 602 PLENUMS <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | SECTION 603 DUCT CONSTRUCTION AND INSTALLATION TABLE 603.4 DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES FOR SINGLE DWELLING UNITS <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | SECTION 604 INSULATION <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | SECTION 605 AIR FILTERS SECTION 606 SMOKE DETECTION SYSTEMS CONTROL <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | SECTION 607 DUCT AND TRANSFER OPENINGS <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | TABLE 607.3.2.1 FIRE DAMPER RATING <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | CHAPTER 7 – COMBUSTION AIR SECTION 701 GENERAL <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | CHAPTER 8 – CHIMNEYS AND VENTS SECTION 801 GENERAL <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | SECTION 802 VENTS TABLE 802.2 VENT APPLICATION <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | SECTION 803 CONNECTORS TABLE 803.9(1) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR LOW-HEAT APPLIANCES TABLE 803.9(2) MINIMUM CHIMNEY CONNECTOR THICKNESS FOR MEDIUM- AND HIGH-HEAT APPLIANCES <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | TABLE 803.10.4 CHIMNEY CONNECTOR SYSTEMS AND CLEARANCES TO COMBUSTIBLE WALL MATERIALS FOR DOMESTIC HEATING APPLIANCES TABLE 803.10.6 CONNECTOR CLEARANCES TO COMBUSTIBLES SECTION 804 DIRECT-VENT, INTEGRAL VENT AND MECHANICAL DRAFT SYSTEMS <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | SECTION 805 FACTORY-BUILT CHIMNEYS <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | SECTION 806 METAL CHIMNEYS <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | CHAPTER 9 – SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT SECTION 901 GENERAL SECTION 902 MASONRY FIREPLACES SECTION 903 FACTORY-BUILT FIREPLACES SECTION 904 PELLET FUEL-BURNING APPLIANCES SECTION 905 FIREPLACE STOVES AND ROOM HEATERS SECTION 906 FACTORY-BUILT BARBECUE APPLIANCES SECTION 907 INCINERATORS AND CREMATORIES SECTION 908 COOLING TOWERS, EVAPORATIVE CONDENSERS AND FLUID COOLERS <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | SECTION 909 VENTED WALL FURNACES SECTION 910 FLOOR FURNACES SECTION 911 DUCT FURNACES SECTION 912 INFRARED RADIANT HEATERS SECTION 913 CLOTHES DRYERS <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | SECTION 914 SAUNA HEATERS SECTION 915 ENGINE AND GAS TURBINE-POWERED EQUIPMENT AND APPLIANCES SECTION 916 POOL AND SPA HEATERS SECTION 917 COOKING APPLIANCES SECTION 918 FORCED-AIR WARM-AIR FURNACES <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | SECTION 919 CONVERSION BURNERS SECTION 920 UNIT HEATERS <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | SECTION 921 VENTED ROOM HEATERS SECTION 922 KEROSENE AND OIL-FIRED STOVES SECTION 923 SMALL CERAMIC KILNS SECTION 924 STATIONARY FUEL CELL POWER SYSTEMS SECTION 925 MASONRY HEATERS SECTION 926 GASEOUS HYDROGEN SYSTEMS SECTION 927 HEAT RECOVERY VENTILATORS <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | CHAPTER 10 – BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL SECTION 1002 WATER HEATERS SECTION 1003 PRESSURE VESSELS SECTION 1004 BOILERS <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | SECTION 1005 BOILER CONNECTIONS SECTION 1006 SAFETY AND PRESSURE RELIEF VALVES AND CONTROLS SECTION 1007 BOILER LOW-WATER CUTOFF <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | SECTION 1008 STEAM BLOWOFF VALVE SECTION 1009 HOT WATER BOILER EXPANSION TANK EQUATION 10-1 SECTION 1010 GAUGES SECTION 1011 TESTS <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | CHAPTER 11 – REFRIGERATION SECTION 1101 GENERAL SECTION 1102 SYSTEM REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | SECTION 1103 REFRIGERATION SYSTEM CLASSIFICATION SECTION 1104 SYSTEM APPLICATION REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | TABLE 1103.1 REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | TABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | TABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | TABLE 1103.1\u2014continued REFRIGERANT CLASSIFICATION, AMOUNT AND OEL <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | TABLE 1104.3.2 MAXIMUM PERMISSIBLE QUANTITIES OF REFRIGERANTS <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | SECTION 1105 MACHINERY ROOM, GENERAL REQUIREMENTS EQUATION 11-1 <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | EQUATION 11-2 SECTION 1106 MACHINERY ROOM, SPECIAL REQUIREMENTS SECTION 1107 REFRIGERANT PIPING <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | SECTION 1108 FIELD TEST SECTION 1109 PERIODIC TESTING <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | CHAPTER 12 – HYDRONIC PIPING SECTION 1201 GENERAL SECTION 1202 MATERIAL TABLE 1202.4 HYDRONIC PIPE TABLE 1202.4\u2014continued HYDRONIC PIPE TABLE 1202.5 HYDRONIC PIPE FITTINGS <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | SECTION 1203 JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | SECTION 1204 PIPE INSULATION <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | SECTION 1205 VALVES SECTION 1206 PIPING INSTALLATION SECTION 1207 TRANSFER FLUID SECTION 1208 TESTS <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | SECTION 1209 EMBEDDED PIPING <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | CHAPTER 13 – FUEL OIL PIPING AND STORAGE SECTION 1301 GENERAL SECTION 1302 MATERIAL TABLE 1302.3 FUEL OIL PIPING SECTION 1303 JOINTS AND CONNECTIONS <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | SECTION 1304 PIPING SUPPORT SECTION 1305 FUEL OIL SYSTEM INSTALLATION <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | SECTION 1306 OIL GAUGING SECTION 1307 FUEL OIL VALVES SECTION 1308 TESTING <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | CHAPTER 14 – SOLAR SYSTEMS SECTION 1401 GENERAL SECTION 1402 INSTALLATION <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | SECTION 1403 HEAT TRANSFER FLUIDS SECTION 1404 MATERIALS <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | CHAPTER 15 – REFERENCED STANDARDS ACCA AHRI ANSI ASHRAE ASME <\/td>\n<\/tr>\n | ||||||
131<\/td>\n | ASSE ASTM <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | AWS <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | AWWA CSA DOL FS ICC <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | IIAR MSS NAIMA NFPA <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | SMACNA UL <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | APPENDIX A COMBUSTION AIR OPENINGS AND CHIMNEY CONNECTOR PASS-THROUGHS FIGURE A-1 ALL AIR FROM INSIDE THE BUILDING FIGURE A-2 ALL AIR FROM OUTDOORS\u2014INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | FIGURE A-3 ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC FIGURE A-4 ALL AIR FROM OUTDOORS THROUGH HORIZONTAL DUCTS OR DIRECT OPENINGS <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | FIGURE A-5 CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | FIGURE A-5\u2014continued CHIMNEY CONNECTOR SYSTEMS <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | APPENDIX B RECOMMENDED PERMIT FEE SCHEDULE B101 MECHANICAL WORK, OTHER THAN GAS PIPING SYSTEMS B102 FEE FOR REINSPECTION B103 TEMPORARY OPERATION INSPECTION FEE B104 SELF-CONTAINED UNITS LESS THAN 2 TONS <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | INDEX <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | ICC-ES PMG PROGRAM <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | INCREASE YOUR CODE KNOWLEDGE <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Virginia Mechanical Code<\/b><\/p>\n |