{"id":72858,"date":"2024-10-17T16:25:00","date_gmt":"2024-10-17T16:25:00","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/awwa-c502-2005\/"},"modified":"2024-10-24T19:08:21","modified_gmt":"2024-10-24T19:08:21","slug":"awwa-c502-2005","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/awwa\/awwa-c502-2005\/","title":{"rendered":"AWWA C502 2005"},"content":{"rendered":"
This standard covers post-type, dry-barrel fire hydrants with compression shutoff (opening against or with the pressure) or gate shutoff for use in water supply service in all climates, including those where freezing occurs.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | ANSI\/AWWA C502-05 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Committee Personnel <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword I. Introduction. <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | II. Special Issues. <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | III. Use of This Standard. <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | IV. Major Revisions. V. Comments. <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | AWWA Standard Dry-Barrel Fire Hydrants SECTION 1: GENERAL Sec. 1.1 Scope Sec. 1.2 Purpose Sec. 1.3 Application <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | SECTION 2: REFERENCES <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | SECTION 3: DEFINITIONS SECTION 4: REQUIREMENTS Sec. 4.1 Permeation <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Sec. 4.2 Data to Be Supplied by the Purchaser Sec. 4.3 Data to Be Supplied by the Manufacturer Sec. 4.4 Materials <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Table 1 Copper alloy standards Sec. 4.5 General Design <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Table 2 Hydrant component parts <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Sec. 4.6 Detailed Design <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Table 3 Minimum wall thicknesses <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Sec. 4.7 Hydrant Inlet <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Table 4 Dimensions of poured joints (for repairs only) Sec. 4.8 Valves <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Sec. 4.9 Packing Glands and Packing-Gland Bolts <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Sec. 4.10 Seals Sec. 4.11 Bolts and Nuts <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Sec. 4.12 Workmanship Sec. 4.13 Painting <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | SECTION 5: VERIFICATION Sec. 5.1 Production Testing Sec. 5.2 Prototype Testing <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Table 5 Maximum permissible loss of head for hydrants Sec. 5.3 Inspection and Nonconformance <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | SECTION 6: DELIVERY Sec. 6.1 Marking Sec. 6.2 Shipping Sec. 6.3 Affidavit of Compliance <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | APPENDIX A \nCharacteristics of National Standard \nFire-Hose Coupling Screw Thread <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Table A.1 Nominal dimensions of NH (fire-hose) threads <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Table A.2 Basic dimensions of NH (fire-hose) threads <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | APPENDIX B Uniform Color Scheme for Fire Hydrants* \n SECTION B.1: CLASSIFICATION Sec. B.1.1 Capacity Rating <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | SECTION B.2: COLOR SCHEME Sec. B.2.1 Public Hydrants Sec. B.2.2 Private Hydrants SECTION B.3: LOCATION MARKERS SECTION B.4: CAPACITY <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" AWWA C502-05: Dry Barrel Fire Hydrants<\/b><\/p>\n |