{"id":72860,"date":"2024-10-17T16:25:02","date_gmt":"2024-10-17T16:25:02","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/awwa-c503-2005\/"},"modified":"2024-10-24T19:08:22","modified_gmt":"2024-10-24T19:08:22","slug":"awwa-c503-2005","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/awwa\/awwa-c503-2005\/","title":{"rendered":"AWWA C503 2005"},"content":{"rendered":"
This standard pertains to the various types and classes of wet-barrel fire hydrants for use in water-supply service in areas where the climate is mild and freezing temperatures do not occur.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | ANSI\/AWWA C503-05 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Committee Personnel <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword I. Introduction. <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | II. Special Issues. III. Use of This Standard. <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | IV. Major Revisions. V. Comments. <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | AWWA Standard Wet-Barrel Fire Hydrants \n SECTION 1: GENERAL Sec. 1.1 Scope <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Sec. 1.2 Purpose Sec. 1.3 Application SECTION 2: REFERENCES <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | SECTION 3: DEFINITIONS <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | SECTION 4: REQUIREMENTS Sec. 4.1 Permeation Sec. 4.2 Data to Be Supplied by the Purchaser Sec. 4.3 Drawings or Data to Be Supplied by the Manufacturer <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Sec. 4.4 Materials <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Table 1 Copper alloys <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Sec. 4.5 General Design Sec. 4.6 Detailed Design <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Table 2 Minimum wall thickness for sections of wet-barrel hydrants <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Table 3 Maximum permissible loss of head for hydrants <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Sec. 4.7 Coating Sec. 4.8 Workmanship <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | SECTION 5: VERIFICATION Sec. 5.1 Inspection Sec. 5.2 Fire-Hydrant Component Tests Sec. 5.3 Production Tests <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Sec. 5.4 Notice of Nonconformance SECTION 6: DELIVERY Sec. 6.1 Marking Sec. 6.2 Preparing for Shipment <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Sec. 6.3 Affidavit of Compliance <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | APPENDIX A Characteristics of National Standard \nFire-Hose Coupling Screw Threads \n <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Table A.1 Nominal dimensions of NH (fire-hose) threads <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Table A.2 Basic dimensions of NH (fire-hose) threads <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | APPENDIX B Uniform Color Scheme for Fire Hydrants \n SECTION B.1: CLASSIFICATION Sec. B.1.1 Capacity Rating <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | SECTION B.2: COLOR SCHEME Sec. B.2.1 Public Hydrants Sec. B.2.2 Private Hydrants SECTION B.3: LOCATION MARKERS SECTION B.4: CAPACITY <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" AWWA C503-05: Wet Barrel Fire Hydrants<\/b><\/p>\n |