{"id":81462,"date":"2024-10-17T18:54:58","date_gmt":"2024-10-17T18:54:58","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-12-34-2010\/"},"modified":"2024-10-24T19:46:49","modified_gmt":"2024-10-24T19:46:49","slug":"ieee-c57-12-34-2010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-12-34-2010\/","title":{"rendered":"IEEE C57.12.34 2010"},"content":{"rendered":"
Revision Standard – Active. Certain electrical, dimensional, and mechanical characteristics are set forth as well as certain safety features of three-phase, 60 Hz, mineral-oil-immersed, self-cooled, pad-mounted, compartmental-type distribution transformers. These transformers are rated 5 MVA and smaller, with the high-voltage limit of 34.5 kV system nominal voltage and below, and with low-voltage limit of 15 kV system nominal voltage and below. This standard covers the connector, bushing, and terminal arrangements for radial- or loop-feed systems. This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C57.12.34-2009 Front Cover <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Title Page <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Introduction Notice to users Laws and regulations Copyrights Updating of IEEE documents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Errata Interpretations Patents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Figures <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Tables <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Important Notice 1. Overview 1.1 Scope <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 2. Normative references <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4. Ratings 4.1 Kilovolt-ampere ratings 4.2 Voltage ratings 4.3 Tap ratings 5. Impedance voltage 5.1 Nominal percent impedance voltage <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.2 Tolerance on impedance voltage 5.3 Tolerance on impedance voltage on a tap 6. Basic lightning impulse insulation levels <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 7. Tests 7.1 General 7.2 Dielectric tests 7.3 Dielectric test levels 8. Construction 8.1 General 8.2 Compartment configuration <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 8.3 Access 8.4 Enclosure security and coating system 8.5 Pad attachment 8.6 Lifting <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 8.7 Connectors, bushings, and terminals <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 8.8 Instruction nameplate <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 8.9 Oil preservation <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 8.10 Tanks 8.11 Grounding provisions <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 8.12 Components for loop primary cable systems 9. Storage 10. Installation 11. Other requirements that may be specified for some applications <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Annex A (informative) Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard Requirements for Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers, 5 MVA and Smaller; High Voltage, 34.5 kV Nominal System Voltage and Below; Low Voltage, 15 kV Nominal System Voltage & Below<\/b><\/p>\n |