ACI 307 2023
$48.21
ACI CODE-307-23: Requirements for Reinforced Concrete Chimneys Code and Commentary
Published By | Publication Date | Number of Pages |
ACI | 2023 | 79 |
This Code provides material, design, and detailing requirements for cast-in-place and precast reinforced concrete chimneys. It sets forth minimum loadings for design and contains methods for determining the concrete and reinforcement required to obtain the strength required by the loadings. The methods of analysis apply primarily to circular chimney walls, but guidance is included for applying the general principles to noncircular chimney walls. Keywords: across-wind load; construction requirements; earthquake load; flexural strength; load combinations; reinforced concrete; reinforced concrete chimneys; structural design; thermal load; vortex shedding; windload.
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | TITLE PAGE |
5 | PREFACE |
6 | CHAPTER 1—GENERAL 1.1—Scope 1.2—General 1.3—Purpose |
7 | 1.4—Applicability 1.5—Interpretation |
8 | 1.6—Building official 1.7—Licensed design professional |
9 | 1.8—Construction documents and design records 1.9—Testing and inspection |
10 | CHAPTER 2—NOTATION AND DEFINITIONS 2.1—Notation |
15 | 2.2—Definitions |
16 | CHAPTER 3—REFERENCED STANDARDS |
17 | CHAPTER 4—STRUCTURAL SYSTEMREQUIREMENTS 4.1—Materials 4.2—Design loads 4.3—Structural system |
18 | CHAPTER 5—CONCRETE: MATERIALS, DESIGN,AND DURABILITY REQUIREMENTS 5.1—General 5.2—Materials |
19 | 5.3—Concrete properties for design |
20 | 5.4—Durability requirements |
21 | CHAPTER 6—REINFORCING STEEL: MATERIALS,DESIGN, AND DURABILITY REQUIREMENTS 6.1—General 6.2—Materials 6.3—Steel properties for design 6.4—Durability requirements |
22 | CHAPTER 7—LOADS 7.1—General 7.2—Dead load 7.3—Temperature gradient load |
25 | 7.4—Wind load |
31 | 7.5—Earthquake load |
35 | 7.6—Load combinations |
37 | CHAPTER 8—DESIGN OF HORIZONTAL CROSSSECTIONS 8.1—General |
38 | 8.2—Design limits |
40 | 8.3—Required strength 8.4—Design strength |
41 | 8.5—Reinforcement limits |
42 | 8.6—Reinforcement detailing |
44 | CHAPTER 9—DESIGN OF VERTICAL CROSSSECTIONS FOR CIRCUMFERENTIAL RINGMOMENTS 9.1—General 9.2—Design limits 9.3—Required strength 9.4—Design strength |
45 | 9.5—Reinforcement limits 9.6—Reinforcement detailing |
47 | CHAPTER 10—OPENING DETAILS 10.1—General 10.2—Minimum wall thickness at openings 10.3—Vertical reinforcement at openings |
48 | 10.4—Circumferential reinforcement at openings |
49 | 10.5—Corner reinforcement at openings |
50 | 10.6—Seismic detailing |
51 | CHAPTER 11—FOUNDATION 11.1—Foundation geotechnical capacity 11.2—Foundation structural design |
52 | 11.3—Reinforcement detailing 11.4—Mass concrete |
53 | CHAPTER 12—CONSTRUCTION REQUIREMENTS 12.1—General 12.2—Concrete strength 12.3—Concrete strength tests 12.4—Formwork |
54 | 12.5—Concrete placement 12.6—Concrete curing 12.7—Reinforcement placement |
55 | 12.8—Construction tolerances 12.9—Precast erection |
56 | COMMENTARY REFERENCES |
58 | APPENDIX A—HORIZONTAL CROSS-SECTIONSTRENGTH FOR CIRCULAR CHIMNEYS BYMODIFIED STRESS BLOCK METHOD |
64 | APPENDIX B—HORIZONTAL CROSS-SECTIONSTRENGTH FOR CIRCULAR CHIMNEYSBY STRESS-STRAIN RELATIONSHIPINTEGRATION METHOD |
69 | APPENDIX C—TEMPERATURE GRADIENTS FORCIRCULAR CHIMNEYS |
72 | APPENDIX D—THERMAL STRESSES FORCIRCULAR CHIMNEYS |
74 | APPENDIX E—CRACKING MOMENT |
75 | APPENDIX F—REVISION HISTORY |