ASME HST 6 2020
$98.04
ASME HST-6 – 2020 Performance Standard for Air Wire Rope Hoists
Published By | Publication Date | Number of Pages |
ASME | 2020 | 35 |
This Standard establishes performance requirements for air wire rope hoists for vertical lifting service involving material handling of freely suspended (unguided) loads using wire rope as the lifting medium with one of the following types of suspension: (1) lug; (2) hook or clevis; (3) trolley; (4) base or deck mounted (does not include winches of the type covered by ASME B30.7). (5) wall or ceiling mounted (does not include winches or the type covered by ASME B30.7). It is applicable to hoists manufactured after the date on which this Standard is issued. It is not applicable to: (1) damaged or malfunctioning hoists; (2) hoists that have been misused or abused; (3) hoists that have been altered without authorization of the manufacturer or a qualified person; (4) hoists used for lifting or supporting people; (5) hoists used for the purpose of drawing both the load and the hoist up or down the hoist’s own wire rope; or (6) hoists used for marine and other applications as required by the Department of Defense (DOD). The requirements of this Standard shall be applied together with the requirements of ASME B30.16. Please also refer to ASME B30.16 for requirements pertaining to marking, construction, and installation; inspection, testing, and maintenance; and operations. The standard includes an appendix on Air Wire Rope Hoists used in marine and other applications as required by the Department of Defense (DOD).
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | CONTENTS |
5 | FOREWORD |
6 | ASME HST COMMITTEE ROSTER |
7 | CORRESPONDENCE WITH THE HST COMMITTEE |
10 | Chapter 6-0 Scope, Definitions, References, and Appendices SECTION 6-0.1: SCOPE SECTION 6-0.2: DEFINITIONS |
12 | SECTION 6-0.3: REFERENCES SECTION 6-0.4: APPENDICES |
13 | Figures Figure 6-0.2-1 Hoist Mounting Headroom, Lift, and Reach |
14 | Figure 6-0.2-2 Single and Double Reeving |
15 | Chapter 6-1 Performance SECTION 6-1.1: GENERAL SECTION 6-1.2: HOIST DUTY SERVICE CLASSIFICATION 6-1.2.1 General Considerations 6-1.2.2 Hazardous Locations 6-1.2.3 Duty Classification SECTION 6-1.3: SPECIFICATIONS OF LIFT, HEADROOM, AND REACH 6-1.3.1 Lift |
16 | 6-1.3.2 Headroom 6-1.3.3 Reach SECTION 6-1.4: SPEEDS — HOIST AND TROLLEY SECTION 6-1.5: TROLLEYS 6-1.5.1 Plain-Type Trolleys Tables Table 6-1.2.3-1 Air Wire Rope Duty Service Classification Table 6-1.4-1 Typical Hoist and Motorized Trolley Speeds |
17 | 6-1.5.2 Hand-Chain-Operated Trolleys 6-1.5.3 Motor-Operated Trolleys 6-1.5.4 Trolley Wheels 6-1.5.5 Air Supply Characteristics |
18 | Chapter 6-2 Mechanical Requirements SECTION 6-2.1: REEVING 6-2.1.1 Single Reeving 6-2.1.2 Double Reeving SECTION 6-2.2: OVERLOAD LIMIT DEVICE SECTION 6-2.3: CONTROL 6-2.3.1 Pendant Control 6-2.3.2 Pull Control 6-2.3.3 Rod Control |
19 | Chapter 6-3 Typical Air Wire Rope Hoist and Trolley Inquiry Data SECTION 6-3.1: INQUIRY DATA FORM |
20 | Form Form 6-3.1-1 Typical Air Wire Rope Hoist and Trolley Inquiry Data Form |
21 | NONMANDATORY APPENDIX A PERFORMANCE REQUIREMENTS FOR AIR WIRE ROPE HOISTS USED IN MARINE AND OTHER APPLICATIONS AS REQUIRED BY THE U.S. DEPARTMENT OF DEFENSE (DOD) A-1 GENERAL |
22 | A-2 PERFORMANCE REQUIREMENTS |
23 | Table A-2.3.1-1 Air Wire Rope Hoist Characteristics |
24 | A-3 MECHANICAL REQUIREMENTS |
25 | Table A-3.6-1 Hook Throat Openings |
26 | A-4 TESTING, MARKING, AND DATA |
27 | A-5 TYPICAL HOIST INQUIRY DATA |
28 | NONMANDATORY APPENDIX B MECHANICAL SPARK RESISTANCE GUIDANCE FOR APPLICATIONS IN HAZARDOUS (POTENTIALLY EXPLOSIVE) LOCATIONS B-1 GENERAL |
29 | B-2 USE OF REFERENCED DOCUMENTS B-3 MECHANICAL SPARK RESISTANCE |
32 | B-4 EXCESSIVE SURFACE TEMPERATURE B-5 HOIST INSPECTION CONSIDERATIONS |