{"id":13991,"date":"2024-10-16T21:29:31","date_gmt":"2024-10-16T21:29:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d7463-2008\/"},"modified":"2024-10-24T11:56:49","modified_gmt":"2024-10-24T11:56:49","slug":"astm-d7463-2008","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d7463-2008\/","title":{"rendered":"ASTM-D7463 2008"},"content":{"rendered":"
Scope<\/strong><\/p>\n 1.1 This test method provides a protocol for capturing, extracting and quantifying the adenosine triphosphate (ATP) content associated with:<\/p>\n 1.1.1 Microorganisms found in conventional liquid fuels with kinematic viscosities (at 40\u00b0<\/span>C) of \u2264<\/span> 8 mm2<\/sup> \u00b7<\/span> s\u2013<\/span>1<\/sup> as described in Table X6.1,<\/p>\n 1.1.2 Microorganisms found in fuel-associated bottom water, and<\/p>\n 1.1.3 Extracellular (non-cellular) ATP present in the sample matrix.<\/p>\n 1.2 The ATP is measured using a patented bioluminescence enzyme assay, whereby light is generated in amounts proportional to the concentration of ATP in the sample. The light is produced and measured quantitatively using dedicated ATP test pens and a dedicated luminometer and reported in (instrument specific) Relative Light Units.<\/p>\n 1.3 This test method is equally suitable for use in the laboratory or field.<\/p>\n 1.4 Although bioluminescence is a reliable and proven method for qualifying and quantifying ATP, this method does not differentiate between ATP from different sources, for example, from different types of microorganism such as bacteria or fungi.<\/p>\n 1.5 For water or capture solution samples, the concentration range of ATP detectable by this test method is 1 \u00d7<\/span> 10\u2013<\/span>11<\/sup> M to 3 \u00d7<\/span> 10\u2013<\/span>8<\/sup> M which is equivalent to 1 \u00d7<\/span> 10\u2013<\/span>14<\/sup> moles\/mL to 3 \u00d7<\/span> 10\u2013<\/span>11<\/sup> moles\/mL for water samples or capture solution. Assuming testing on fuel phase is performed on a 500 mL volume of fuel the equivalent concentrations is fuel would be: 6 \u00d7<\/span> 10\u2013<\/span>11<\/sup> M to 2 \u00d7<\/span> 10\u2013<\/span>14<\/sup> M.<\/p>\n 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n Keywords<\/strong><\/p>\n adenosine triphosphate; ATP; bacteria; biocontamination; biodeterioration; biomass; fuel; fungi; microbe; microbiology<\/p>\n ICS Code<\/strong><\/p>\n ICS Number Code 07.100.99 (Other standards related to microbiology)<\/p>\n DOI:<\/strong> 10.1520\/D7463-08<\/p>\n<\/div>\n D7463-08 Standard Test Method for Adenosine Triphosphate (ATP) Content of Microorganisms in Fuel, Fuel\/Water Mixtures and Fuel Associated Water<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology <\/td>\n<\/tr>\n\n 2<\/td>\n Summary of Test Method
Significance and Use
Interferences <\/td>\n<\/tr>\n\n 3<\/td>\n Apparatus
Reagents and Materials
Sampling, Test Specimens, and Test Units
Calibration and Standardization
Procedure
FIG. 1 <\/td>\n<\/tr>\n\n 4<\/td>\n FIG. 2 <\/td>\n<\/tr>\n \n 5<\/td>\n Calculation and Report
Precision and Bias
Keywords
X1. DETERMINATION OF FUEL PHASE ATP (FUEL-WATER SAMPLES WITH 10 mL FREE-WATER)
X1.1
X1.2
X1.3
X1.4 <\/td>\n<\/tr>\n\n 6<\/td>\n X2. DETERMINATION OF WATER-PHASE ATP (FUEL-WATER SAMPLES WITH 10 mL FREE-WATER)
X2.1
X2.2
X2.3
X2.4
X3. DETERMINATION OF EXTRACELLULAR ATP
X3.1
X3.2
X3.3
X3.4
X3.5
X3.6
X4. RESOLVING MATRIX INTERFERENCES IN WATER SAMPLES
X4.1
X4.2
X4.3
X4.4
X4.5
X4.6
X5. STANDARD CURVE, METHOD
X5.1
X5.2
X5.3
X5.4
X5.5
X5.6
X5.7 <\/td>\n<\/tr>\n\n 7<\/td>\n X6. TYPICAL KINEMATIC VISCOSITIES FOR VARIOUS FUELS
X6.1
TABLE X6.1 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2008<\/td>\n 7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":13992,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[126,2637],"product_tag":[],"class_list":{"0":"post-13991","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-07-100-99","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/13991","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/13992"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=13991"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=13991"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=13991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}