ACI 550.3 2013 RA 2022
$39.81
ACI CODE-550.3-13 Design Specification for Unbonded Post-Tensioned Precast Concrete Special Moment Frames Satisfying ACI 374.1 (Reapproved 2022)
Published By | Publication Date | Number of Pages |
ACI | 2013 | 32 |
This Standard defines requirements that may be used to design special hybrid moment frames composed of discretely jointed precast concrete beams post-tensioned to concrete columns. After a major earthquake, these hybrid moment frames should exhibit minimal damage in beam-column regions and negligible permanent displacements. Hybrid moment frames do not satisfy the prescriptive requirements of Chapter 21 of ACI 318-11 for frames of monolithic construction. According to 21.1.1.8 of ACI 318-11, their acceptance requires demonstration by experimental evidence and analysis that the frames have strength and toughness equal to or exceeding those provided by comparable monolithic reinforced concrete frames that satisfy the prescriptive requirements of Chapter 21. This Standard describes the requirements that the licensed design professional may use to demonstrate, through analysis, that such frames have strength and toughness at least equal to those of comparable monolithic frames. This Standard is a revision of the ACI T1.2 Standard. In this Standard, consistent with the format of ACI 318, the word “Section” is not included before a reference to a section of ACI 318. To more clearly designate a section of this Standard, however, the word “Section” is used before any reference to a section of this Standard. Consistent with the format of ASCE/SEI 7, the word “Section” is also included before a reference to a section of ASCE/SEI 7. Keywords: drift ratio; earthquake-resistant design; energy dissipation; moment frame; post-tensioning; precast concrete; prestressed concrete; test module; toughness.
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | TITLE PAGE |
5 | CHAPTER 1—GENERAL 1.1—Introduction |
6 | 1.2—Scope |
8 | 1.3—Structural drawings 1.4—Units |
9 | CHAPTER 2—NOTATION AND DEFINITIONS 2.1—Notation |
10 | 2.2—Definitions |
12 | CHAPTER 3—REFERENCED STANDARDS |
13 | CHAPTER 4—MATERIALS 4.1—General 4.2—Ducts 4.3—Energy-dissipating reinforcement 4.4—Prestressing strands and tendons R4—MATERIALS |
14 | 4.5—Interface grout 4.6—Grout for anchorage of energy-dissipating reinforcement |
15 | CHAPTER 5—FRAMING SYSTEM REQUIREMENTS 5.1—General 5.2—Strength 5.3—Drift |
16 | 5.4—Moment frame characteristics |
17 | 5.5—Distribution of moment frames within structures |
18 | 5.6—Moment frame-floor slab interactions |
19 | CHAPTER 6—DESIGN REQUIREMENTS FOR BEAMS OF MOMENT FRAMES 6.1—Prestress 6.2—Beam design |
21 | CHAPTER 7—REQUIREMENTS FOR BEAM-COLUMN INTERFACES OF MOMENT FRAMES 7.1—General 7.2—Prestress force 7.3—Interface grout |
22 | 7.4—Energy-dissipating reinforcement 7.5—Nominal flexural strength 7.6—Probable flexural strength |
25 | 7.7—Anchorage of energy-dissipating reinforcement |
27 | 7.8—Distribution of flexural reinforcement |
28 | CHAPTER 8—FRAME JOINTS 8.1—General |
29 | R9—COMMENTARY REFERENCES Authored references |