Proposes requirements for the design, and test methods for, drive units, leaves and components of powered pedestrian doors, including constructions that are operated electro-mechanically, electro-hydraulically or pneumatically.
Scope
This Standard sets out the requirements for design and test methods for drive units, leaves and components of powered pedestrian doors. Such door constructions may be operated electro-mechanically, electro-hydraulically or pneumatically.
This Standard also provides requirements for design of the installation, verification/testing, marking and commissioning of the complete powered pedestrian door installation.
This Standard does not apply to the following:
(a) Powered doors where the door leaves move vertically.
(b) Powered doors mainly intended for vehicular traffic or access for goods.
(c) Powered pedestrian gates or barriers.
(d) Powered pedestrian turnstiles.
(e) Powered doors used on lifts.
(f) Power operated in environments where there is risk of explosion.