Powered doors for pedestrian access and egress

Published By Publication Date Number of Pages
AS 2007-09-12 81
Guaranteed Safe Checkout
Categories: , ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

Proposes requirements for the design, and test methods for, drive units, leaves and components of powered pedestrian doors, including constructions that are operated electro-mechanically, electro-hydraulically or pneumatically.

Scope

This Standard sets out the requirements for design and test methods for drive units, leaves and components of powered pedestrian doors. Such door constructions may be operated electro-mechanically, electro-hydraulically or pneumatically.
This Standard also provides requirements for design of the installation, verification/testing, marking and commissioning of the complete powered pedestrian door installation.
This Standard does not apply to the following:
(a) Powered doors where the door leaves move vertically.
(b) Powered doors mainly intended for vehicular traffic or access for goods.
(c) Powered pedestrian gates or barriers.
(d) Powered pedestrian turnstiles.
(e) Powered doors used on lifts.
(f) Power operated in environments where there is risk of explosion.