ASHRAE 15 01:2001 Edition
$18.96
ASHRAE Standard 15 Safety Standard for Refrigeration Systems (ANSI approved)
Published By | Publication Date | Number of Pages |
ASHRAE | 2001 | 54 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
3 | Contents Contents |
5 | FOREWORD FOREWORD |
6 | 2.1 This standard establishes safeguards for life, limb, health, and property and prescribes saf… 2.1 This standard establishes safeguards for life, limb, health, and property and prescribes saf… 2.2 This standard applies 2.2 This standard applies |
8 | 4.1 Locations of refrigerating systems are described by occupancy classifications that consider … 4.1 Locations of refrigerating systems are described by occupancy classifications that consider … |
9 | 4.2 Equipment, other than piping, located outside a building and within 20 ft (6.1 m) of any bui… 4.2 Equipment, other than piping, located outside a building and within 20 ft (6.1 m) of any bui… 5.1 Refrigerating Systems. These systems are defined by the method employed for extracting or de… 5.1 Refrigerating Systems. These systems are defined by the method employed for extracting or de… Figure 1 Refrigerating system designation. Figure 1 Refrigerating system designation. |
10 | Table 1 Refrigeranta and Amountsb,e Table 1 Refrigeranta and Amountsb,e |
11 | 5.2 Refrigeration System Classification. For the purpose of applying Tables 1 and 2, a refrigera… 5.2 Refrigeration System Classification. For the purpose of applying Tables 1 and 2, a refrigera… 5.3 Changing Refrigerant. A change in the type of refrigerant in a system shall not be made with… 5.3 Changing Refrigerant. A change in the type of refrigerant in a system shall not be made with… |
13 | 8.1 Foundations. Foundations and supports for condensing units or compressor units shall be of n… 8.1 Foundations. Foundations and supports for condensing units or compressor units shall be of n… 8.2 Guards. Moving machinery shall be guarded in accordance with approved safety standards.3 8.2 Guards. Moving machinery shall be guarded in accordance with approved safety standards.3 8.3 Safe Access. A clear and unobstructed approach and space shall be provided for inspection, s… 8.3 Safe Access. A clear and unobstructed approach and space shall be provided for inspection, s… 8.4 Water Connections. Water supply and discharge connections shall be made in accordance with t… 8.4 Water Connections. Water supply and discharge connections shall be made in accordance with t… 8.5 Electrical Safety. Electrical equipment and wiring shall be installed in accordance with the… 8.5 Electrical Safety. Electrical equipment and wiring shall be installed in accordance with the… 8.6 Gas Fuel Equipment. Gas fuel devices and equipment used with refrigerating systems shall be … 8.6 Gas Fuel Equipment. Gas fuel devices and equipment used with refrigerating systems shall be … 8.7 Air Duct Installation. Air duct systems of air-conditioning equipment for human comfort usin… 8.7 Air Duct Installation. Air duct systems of air-conditioning equipment for human comfort usin… 8.8 Refrigerant Parts in Air Duct. Joints and all refrigerant-containing parts of a refrigeratin… 8.8 Refrigerant Parts in Air Duct. Joints and all refrigerant-containing parts of a refrigeratin… 8.9 Refrigerant Pipe Joint Inspection. Refrigerant pipe joints erected on the premises shall be … 8.9 Refrigerant Pipe Joint Inspection. Refrigerant pipe joints erected on the premises shall be … 8.10 Location of Refrigerant Piping 8.10 Location of Refrigerant Piping |
14 | 8.11 Refrigerating Machinery Room, General Requirements. When a refrigerating system is located … 8.11 Refrigerating Machinery Room, General Requirements. When a refrigerating system is located … |
15 | 8.12 Machinery Room, Special Requirements. In cases specified in the rules of 7.4, a refrigerati… 8.12 Machinery Room, Special Requirements. In cases specified in the rules of 7.4, a refrigerati… 8.13 Manual Emergency Discharge of Ammonia Refrigerant. When required by the authority having ju… 8.13 Manual Emergency Discharge of Ammonia Refrigerant. When required by the authority having ju… 8.14 Purge Discharge. The discharge from purge systems shall be governed by the same rules as pr… 8.14 Purge Discharge. The discharge from purge systems shall be governed by the same rules as pr… 9.1 Materials 9.1 Materials 9.2 System Design Pressure 9.2 System Design Pressure |
16 | 9.3 Refrigerant-Containing Pressure Vessels 9.3 Refrigerant-Containing Pressure Vessels 9.4 Pressure-Relief Protection 9.4 Pressure-Relief Protection |
17 | 9.5 Setting of Pressure-Relief Devices 9.5 Setting of Pressure-Relief Devices 9.6 Marking of Relief Devices and Fusible Plugs 9.6 Marking of Relief Devices and Fusible Plugs 9.7 Pressure Vessel Protection 9.7 Pressure Vessel Protection |
19 | 9.8 Positive Displacement Compressor Protection. When equipped with a stop valve in the discharg… 9.8 Positive Displacement Compressor Protection. When equipped with a stop valve in the discharg… |
20 | TABLE 3 Pressure-Relief Valve Discharge Line Capacity (lb/min of air) of Various Discharge Line… TABLE 3 Pressure-Relief Valve Discharge Line Capacity (lb/min of air) of Various Discharge Line… |
24 | 9.9 Pressure-Limiting Devices 9.9 Pressure-Limiting Devices 9.10 Refrigerant Piping, Valves, Fittings, and Related Parts 9.10 Refrigerant Piping, Valves, Fittings, and Related Parts 9.11 Components Other Than Pressure Vessels and Pip ing 9.11 Components Other Than Pressure Vessels and Pip ing 9.12 Service Provisions 9.12 Service Provisions |
25 | 9.13 Fabrication 9.13 Fabrication 9.14 Factory Tests 9.14 Factory Tests 9.15 Nameplate. Each unit system and each separate condensing unit, compressor, or compressor un… 9.15 Nameplate. Each unit system and each separate condensing unit, compressor, or compressor un… |
26 | 11.2 Signs and Identification 11.2 Signs and Identification 11.3 Charging, Withdrawal, and Disposition of Refrigerants. No service containers shall be left … 11.3 Charging, Withdrawal, and Disposition of Refrigerants. No service containers shall be left … 11.4 Containers. Containers used for refrigerants withdrawn from a refrigerating system shall be… 11.4 Containers. Containers used for refrigerants withdrawn from a refrigerating system shall be… 11.5 Storing Refrigerant. The total amount of refrigerant stored in a machinery room in all cont… 11.5 Storing Refrigerant. The total amount of refrigerant stored in a machinery room in all cont… 11.6 Maintenance. Refrigerating systems shall be maintained by the user in a clean condition, fr… 11.6 Maintenance. Refrigerating systems shall be maintained by the user in a clean condition, fr… |
27 | 11.7 Responsibility for Operation and Emergency Shutdown. It shall be the duty of the person in … 11.7 Responsibility for Operation and Emergency Shutdown. It shall be the duty of the person in … 12. Precedence with Conflicting Requirements 12. Precedence with Conflicting Requirements 13. Listed equipment 13. Listed equipment |
28 | A1 For 100 lb of blend, determine the ideal gas volumes occupied by each component and by the bl… A1 For 100 lb of blend, determine the ideal gas volumes occupied by each component and by the bl… A2 Determine the dilution volume required for the 100 lb of blend and each component therein. A2 Determine the dilution volume required for the 100 lb of blend and each component therein. A3 Determine the maximum allowable concentration (Cm) of a blend. A3 Determine the maximum allowable concentration (Cm) of a blend. B1 Introduction B1 Introduction B2 Emergency Discharge Lines B2 Emergency Discharge Lines B3 Stop Valves B3 Stop Valves B4 Sizing Valves and Lines B4 Sizing Valves and Lines B5 High- to Low-Pressure Valve B5 High- to Low-Pressure Valve B6 Diffuser B6 Diffuser |
29 | B7 Sizing Headers and Diffusers B7 Sizing Headers and Diffusers B8 Location of Diffuser B8 Location of Diffuser B9 Provide Drip Legs B9 Provide Drip Legs B10 Ammonia Diffusion Systems B10 Ammonia Diffusion Systems B11 Ammonia Discharge Lines B11 Ammonia Discharge Lines B12 Ammonia Flares B12 Ammonia Flares B13 Water Tanks B13 Water Tanks B14 Basins B14 Basins B15 Ammonia-Water Mixers B15 Ammonia-Water Mixers B16 Design Responsibility B16 Design Responsibility |
32 | (This appendix is part of this standard and is required for its use.) (This appendix is part of this standard and is required for its use.) APPENDIX H APPENDIX H |
33 | (This appendix is not part of this standard but is included for information purposes only.) (This appendix is not part of this standard but is included for information purposes only.) Appendix I Appendix I Emergencies in Refrigerating Machinery Rooms Emergencies in Refrigerating Machinery Rooms |
34 | (This appendix is not part of this standard but is included for information purposes only.) (This appendix is not part of this standard but is included for information purposes only.) appendix j appendix j addenda description information addenda description information Table J-1 Addenda to ANSI/ASHRAE Standard 15-1994, Changes Identified Table J-1 Addenda to ANSI/ASHRAE Standard 15-1994, Changes Identified |
36 | Table J-2 Addenda to ANSI/ASHRAE Standard 15-1994, Approval Dates Table J-2 Addenda to ANSI/ASHRAE Standard 15-1994, Approval Dates |
52 | ANSI/ASHRAE STANDARD 15-2001 ANSI/ASHRAE STANDARD 15-2001 |
53 | ANSI/ASHRAE STANDARD 15-2001 ANSI/ASHRAE STANDARD 15-2001 |
54 | February 10, 2005 February 10, 2005 Page Page |