Shopping Cart

No products in the cart.

ASHRAE G16 03:2003 Edition

$16.25

ASHRAE Guideline 16-2003 Selecting Outdoor, Return, and Relief Dampers for Air-Side Economizer Systems

Published By Publication Date Number of Pages
ASHRAE 2003 20
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
3 Contents
Contents
4 FOREWORD
FOREWORD
1. PURPOSE
1. PURPOSE
2. SCOPE
2. SCOPE
3. DEFINITIONS
3. DEFINITIONS
4. SYSTEM ARRANGEMENTS
4. SYSTEM ARRANGEMENTS
5 Figure 1 Arrangement 1. HVAC system with a return fan (with minimum outdoor air control Approach…
Figure 1 Arrangement 1. HVAC system with a return fan (with minimum outdoor air control Approach…
6 Figure 2 Arrangement 2. HVAC system with a relief fan (with minimum outdoor air control Approach…
Figure 2 Arrangement 2. HVAC system with a relief fan (with minimum outdoor air control Approach…
7 Figure 3 Arrangement 3. HVAC system with a gravity or motorized relief damper (with minimum outd…
Figure 3 Arrangement 3. HVAC system with a gravity or motorized relief damper (with minimum outd…
8 Figure 4 Overlapping damper control.
Figure 4 Overlapping damper control.
Figure 5 Sequenced damper control.
Figure 5 Sequenced damper control.
10 5. DAMPER SELECTION RATIONALE
5. DAMPER SELECTION RATIONALE
11 Figure 6 Installed opposed blade damper characteristic curves.3,7
Figure 6 Installed opposed blade damper characteristic curves.3,7
Figure 7 Installed parallel blade damper characteristic curves.4,7
Figure 7 Installed parallel blade damper characteristic curves.4,7
6. REFERENCES
6. REFERENCES
12 Figure 8 Airflow measurement test setup for Figures 9 and 10.
Figure 8 Airflow measurement test setup for Figures 9 and 10.
13 Figure 12 Performance of parallel blade dampers in return air and outdoor air paths at 0.38 in. …
Figure 12 Performance of parallel blade dampers in return air and outdoor air paths at 0.38 in. …
Figure 13 Performance of parallel blade dampers in return air and outdoor air paths at 0.50 in. …
Figure 13 Performance of parallel blade dampers in return air and outdoor air paths at 0.50 in. …
15 Figure C-1 Schematic of example problem (continued on next page).
Figure C-1 Schematic of example problem (continued on next page).
16 Figure C-1 Schematic of example problem (concluded).
Figure C-1 Schematic of example problem (concluded).
ASHRAE G16 03
$16.25