Shopping Cart

No products in the cart.

ASHRAE Standard 62.2 2016

$47.13

ASHRAE Standard 62.2-2016 – Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI Approved)

Published By Publication Date Number of Pages
ASHRAE 2016 52
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The 2016 edition of ANSI/ASHRE Standard 62.2 makes two major changes to scope by including unvented space heaters as a potential contaminant source and by expanding “covered dwellings” to include all multifamily dwelling units. A number of other significant changes are also incorporated. A minimal calculated mechanical ventilation rate is provided for existing buildings, below which installation of whole-house ventilation is not required; a distinction is now made between range hoods and other kitchen ventilation options; new methods are provided for determining an infiltration credit for horizontally attached multifamily dwelling units and for determining requirements for a variety of noncontinuous ventilation strategies; and a maximum short-term relative exposure limit is implemented for the first time. Standard 62.2 defines the roles of and minimum requirements for mechanical and natural ventilation systems and the building envelope intended to provide acceptable indoor air quality in low-rise residential buildings. As in the previous editions of this standard, there are three primary sets of requirements and a number of secondary ones. The three primary sets involve whole-building ventilation, local demand-controlled exhaust, and source control. The secondary requirements focus on properties of specific items needed to achieve the main objectives of the standard. Standard 62.2 applies to spaces intended for human occupancy within single-family houses and multifamily structures, including manufactured and modular houses. This standard does not apply to transient housing such as hotels, motels, nursing homes, dormitories, or jails. The standard considers chemical, physical, and biological contaminants that can affect air quality. It does not address thermal comfort requirements, specific pollutant concentration levels, or certain potential pollutant sources such as unvented combustion space heaters and contamination from outdoor sources or from episodic occupant-controlled events such as painting, smoking, cleaning, or other high-polluting events.

PDF Catalog

PDF Pages PDF Title
1 ANSI/ASHRAE Standard 62.2-2016
3 CONTENTS
4 FOREWORD
1. PURPOSE
2. SCOPE
5 3. DEFINITIONS
6 4. DWELLING-UNIT VENTILATION
8 5. LOCAL EXHAUST
9 6. OTHER REQUIREMENTS
11 7. AIR-MOVING EQUIPMENT
8. CLIMATE DATA
9. REFERENCES
14 NORMATIVE APPENDIX A—EXISTING BUILDINGS
15 NORMATIVE APPENDIX B—INFILTRATION EFFECTIVENESS WEATHER AND SHIELDING FACTORS
43 NORMATIVE APPENDIX C—RELATIVE EXPOSURE
45 INFORMATIVE APPENDIX D—ADDENDA DESCRIPTION INFORMATION
ASHRAE Standard 62.2 2016
$47.13