ASME CSD 1 2012

$98.04

ASME CSD-1 Controls and Safety Devices for Automatically Fired Boilers

Published By Publication Date Number of Pages
ASME 2012 72
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The rules of this Standard cover requirements for the assembly, installation, maintenance, and operation of controls and safety devices on automatically operated boilers directly fired with gas, oil, gas-oil, or electricity, having fuel input ratings under 12,500,000 Btu/hr.

PDF Catalog

PDF Pages PDF Title
7 FOREWORD
8 COMMITTEE ROSTER
9 CORRESPONDENCE WITH THE CSDAFB COMMITTEE
10 SUMMARY OF CHANGES
11 Part CG General
CG-100 GENERAL REQUIREMENTS
12 CG-200 GENERAL PROVISIONS
CG-300 MATERIAL REQUIREMENTS
CG-400 TESTING AND MAINTENANCE
13 CG-500 CERTIFICATION AND REPORTING
CG-600 OPERATION
CG-700 DEFINITIONS
17 Figure
Fig. CG-1 Sediment Trap
19 Part CM Testing and Maintenance
CM-100 PERIODIC TESTING AND MAINTENANCE
20 Part CE Electrical
CE-100 ELECTRICAL REQUIREMENTS
22 Part CW Steam and Waterside Control
CW-100 AUTOMATIC LOW-WATER FUEL CUTOFFAND/OR COMBINED WATER FEEDINGDEVICE
24 CW-200 AUTOMATIC FUEL CUTOFF FOR FORCEDCIRCULATION BOILERS
CW-300 PRESSURE CONTROLS
25 CW-400 TEMPERATURE CONTROLS
CW-500 SAFETY AND SAFETY RELIEF VALVES
CW-600 MODULAR BOILERS
26 CW-700 VACUUM BOILERS
27 Part CF Combustion Side Control
CF-100 GAS-FIRED BOILER UNITS, EQUIPMENT
28 Tables
Table CF-1 400,000 Btu/hr (117 kW) and Smaller (Gas — Natural Draft)
29 Table CF-2 400,000 Btu/hr (117 kW) and Smaller (Power Gas Burners and Mechanical Draft Atmospheric Gas Burners), 3 gph (11.4 L/h) and Smaller (Oil)
31 Table CF-3 Safety Controls for Automatically Fired Units: Power Gas Burners and Mechanical Draft Atmospheric Gas Burners
32 Table CF-4 Safety Controls for Automatically Fired Units: Atmospheric Gas Burners — Natural Draft
35 CF-200 GAS-FIRED BOILER UNITS, PURGING
CF-300 GAS-FIRED BOILER UNITS, SAFETY CONTROLS
36 CF-400 OIL-FIRED BOILER UNITS, EQUIPMENT
38 Table CF-5 Safety Controls for Automatically Fired Units: Oil-Fired Burners
39 CF-500 OIL-FIRED BOILER UNITS, SAFETY CONTROLS
CF-600 LOW FIRE START, GAS- OR OIL-FIRED BOILER UNITS
CF-700 COMBINATION GAS- AND OIL-FIRED UNITS
CF-800 ELECTRICALLY HEATED BOILERS
40 CF-900 COMBUSTION SIDE CONTROLS FOR MODULAR BOILERS
41 NONMANDATORY APPENDICES

A COMPARISON OF THIS STANDARD AND ANSI Z21.13/CSA 4.9
42 B TYPICAL FUEL TRAINS
49 C MANUFACTURER’S /INSTALLING CONTRACTOR’S REPORT FORASME CSD-1
52 D RECOMMENDED PREVENTIVE MAINTENANCE SCHEDULE
56 E REFERENCES
57 F GUIDANCE FOR THE USE OF U.S. CUSTOMARY AND SI UNITS IN ASME CSD-1
61 INDEX