ASTM-C1840/C1840M:2024 Edition

$34.13

C1840/C1840M-24 Standard Practice for Inspection and Acceptance of Installed Reinforced Concrete Culvert, Storm Drain, and Storm Sewer Pipe

Published By Publication Date Number of Pages
ASTM 2024 9
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM C1840/C1840M-24

Active Standard: Standard Practice for Inspection and Acceptance of Installed Reinforced Concrete Culvert, Storm Drain, and Storm Sewer Pipe

ASTM C1840/C1840M

Scope

1.1 This practice covers the requirements for inspection and acceptance of installed reinforced concrete pipe by either person-entry, or remote inspection as shown in Figs. 1 and 2, respectively.

FIG. 1 Person Entry Inspection

FIG. 2 Remote Inspection Camera

1.2 The scope of this specification is intended for installation related observations and assumes that pre-installation inspection has been completed.

1.3 The reinforced concrete culvert, storm drain and storm sewer pipe shall be manufactured in accordance with Specification C76, C506, C507, C655, C1417, or C1846/C1846M and accepted in accordance with AASHTO R 73. This specification shall only be used for gravity, non-pressure storm drainage applications.

1.4 Person Entry shall be used unless extenuating circumstances preclude this type inspection. Remote inspection is acceptable for use for pipe diameters of 30 in. [750 mm] and smaller unless otherwise specified by owner or engineer.

1.5 Access of installed pipe for manual inspection shall follow OSHA 29 CFR PART 1926 SUBPART AA regulations for confined space entry. However, this standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This practice does not cover deformation or deflection assessment. Concrete pipe is classified as a rigid structure because they do not bend or deflect appreciably under load before cracking. Due to these facts shape evaluation are of little or no value when evaluating concrete pipe.

1.7 The values stated in either Imperial/US or [SI units] are to be regarded separately as standard. The SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Keywords

acceptance; arch pipe; circular pipe; culvert; elliptical pipe; evaluation; inspection; reinforced concrete pipe; remediation; sewer pipe; storm drain;

ICS Code

ICS Number Code 23.040.50 (Pipes and fittings of other materials)

DOI: 10.1520/C1840_C1840M-24