ASTM-C91:2005 Edition
$35.75
C91-05 Standard Specification for Masonry Cement
Published By | Publication Date | Number of Pages |
ASTM | 2005 | 4 |
1.1 This specification covers three types of masonry cement for use where mortar for masonry is required.
1.2 The values stated in SI units are to be regarded as the standard. Values in SI units shall be obtained by measurement in SI units or by appropriate conversion of measurements made in other units, using the Rules for Conversion and Rounding given in IEEE/ASTM SI 10.
1.3 The text of this standard refers to notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.4 The following safety hazards caveat pertains only to Sections 16 and 17 of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. ( Warning Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.)
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Classification |
2 | Physical Properties Sampling Temperature and Humidity Fineness Normal Consistency Autoclave Expansion Time of Setting Density Blended Sand Preparation of Mortar TABLE 1 |
3 | Air Entrainment Compressive Strength Water Retention Storage Inspection Rejection Manufacturer’s Certification Packaging and Package Marking TABLE 2 |
4 | Keywords |