Shopping Cart

No products in the cart.

ASTM-C94 2011

$44.96

C94/C94M-11a Standard Specification for Ready-Mixed Concrete

Published By Publication Date Number of Pages
ASTM 2011 12
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This specification covers ready-mixed concrete as defined in 3.2.2. Requirements for quality of concrete shall be either as hereinafter specified or as specified by the purchaser. In any case where the requirements of the purchaser differ from these in this specification, the purchaser’s specification shall govern. This specification does not cover the placement, consolidation, curing, or protection of the concrete after delivery to the purchaser.

1.2 The values stated in either SI units, shown in brackets, or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.3 As used throughout this specification the manufacturer produces ready-mixed concrete. The purchaser buys ready-mixed concrete.

1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

1.5 This standard does not purport to address all the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. ( Warning Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged use. )

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
Basis of Purchase
Materials
Ordering Information
TABLE 1
4 Tolerances in Slump or Slump Flow
Air-Entrained Concrete
Measuring Materials
5 Batching Plant
Mixers and Agitators
6 Mixing and Delivery
7 Use of Nonagitating Equipment
Batch Ticket Information
8 Plant Inspection
Practices, Test Methods, and Reporting
Sampling and Testing Fresh Concrete
Strength
9 Failure to Meet Strength Requirements
Keywords
A1. CONCRETE UNIFORMITY REQUIREMENTS
A1.1
A1.2
TABLE A1.1
10 A1.3
X1. Calculation of the Average Compressive Strength (f ‘cr), Necessary to Meet the Strength Requirements of Sections
X1.1
TABLE X1.1
11 TABLE X1.2
TABLE X1.3
ASTM-C94 2011