D3362-05 Standard Test Method for Purity of Acrylate Esters by Gas Chromatography (Withdrawn 2011)
Published By | Publication Date | Number of Pages |
ASTM | 2005 | 4 |
ASTM D3362-05
Withdrawn Standard: Standard Test Method for Purity of Acrylate Esters by Gas Chromatography (Withdrawn 2011)
ASTM D3362
Scope
1.1 This test method covers the determination of the purity of acrylate, ethyl acrylate, n-butyl acrylate, and 2-ethylhexyl acrylate by gas chromatography and, in addition, provides a means for measuring certain impurities such as alcohols and other esters. Water and acidity are measured by other appropriate ASTM procedures and the results are used to normalize the chromatographic values.
1.2 The following applies to all specified limits in this standard; for purposes of determining conformance with this standard, an observed value or a calculated value shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E 29.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 For hazard information and guidance, see the supplier’s Material Safety Data Sheet.
1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.
Keywords
acrylate esters; acrylates; ethyl acrylate; gas chromatography analysis; n-butyl acrylate; methyl acrylate; purity; 2-ethylhexyl acrylate
ICS Code
ICS Number Code 71.080.60 (Alcohols. Ethers)
DOI: 10.1520/D3362-05
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Summary of Method Significance and Use Apparatus |
2 | Reagents and Materials Safety Precautions Preparation of Apparatus Calibration and Standardization TABLE 1 |