ASTM-D3645 2008

$40.63

D3645-08 Standard Test Methods for Beryllium in Water

Published By Publication Date Number of Pages
ASTM 2008 6
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 These test methods cover the determination of dissolved and total recoverable beryllium in most waters and wastewaters:

1.2 The analyst should direct attention to the precision and bias statements for each test method. It is the user’s responsibility to ensure the validity of these test methods for waters of untested matrices.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 12 and 23.4.

7.1 This test method is applicable in the range from 10 to 500 ? g/L of beryllium. The range may be extended upward by dilution of the sample.

7.2 The precision and bias data were obtained on reagent water, tap water, salt water, river water, lake water, spring water, and untreated wastewater. The information on precision and bias may not apply to other waters. It is the user’s responsibility to ensure the validity of this test method for waters of untested matrices.

17.1 This test method covers the determination of dissolved and total recoverable beryllium in most waters and wastewaters.

17.2 This test method is applicable in the range from 10 to 50 ? g/L of beryllium using a 20- ? L injection. The range can be increased or decreased by varying the volume of sample injected or the instrumental settings. High concentrations may be diluted but preferably should be analyzed by direct-aspiration atomic-absorption spectrophotometry.

17.3 This test method has been used successfully with reagent water, lake water, river water, well water, filtered tap water, and a condensate from a medium Btu coal gasification process. It is the user’s responsibility to ensure validity of this test method to waters of untested matrices.

17.4 The analyst is encouraged to consult Practice D 3919 for a general discussion of interferences and sample analysis procedures for graphite furnace atomic absorption spectrophotometry.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Significance and Use
Purity of Reagents
2 Sampling
Scope
Summary of Test Method
Interferences
Apparatus
Reagents and Materials
Hazards
3 Standardization
Procedure
Calculation
Precision and Bias
Scope
TABLE 1
TABLE 2
4 Summary of Test Method
Interferences
Apparatus
Reagents and Materials
Standardization
Procedure
Calculation
TABLE 3
5 Precision and Bias
Quality Control
6 Keywords
ASTM-D3645 2008
$40.63