ASTM-D5572 2005
$44.96
D5572-95(2005) Standard Specification for Adhesives Used for Finger Joints in Nonstructural Lumber Products
Published By | Publication Date | Number of Pages |
ASTM | 2005 | 17 |
1.1 This specification establishes performance levels for adhesives to be used in finger joints in nonstructural bonded-lumber products. Such products include, but are not limited to, interior and exterior mouldings, window and door components or parts, and bonded-lumber panels. Adhesives that meet the requirements of the various performance classes are considered capable of providing an adequate bond for use under the conditions described for the class. This specification is to be used to evaluate adhesives as well as the adhesive bonds in the finger joints. See Section , Significance and Use, for limitations when using this specification to evaluate industrially manufactured finger joints. Note 1This specification supersedes the finger-joint portion of the 1990 edition of Specification D 3110.
1.2 The following index is provided as a guide to the test methods in this specification:
Section Apparatus Equipment, Material, and Preparation of Assemblies and Specimens Conditioning for Factory-Manufactured Assemblies, Laboratory-Made Assemblies, and Test Specimens Testing in Flexure Testing in Tension Exposure Conditions and Treatments 1.Dry Use Tests: Dry, 3-cycle Soak, Elevated Temperature, and Temperature-Humidity 2.Wet Use Tests: Dry, Boil, Elevated Temperature, and Vacuum-Pressure Note 2
The conditioning needed for various stages in the preparation of both types of specimens and for the exposure tests are given.
Note 3
Specific guidelines for specimen size, exposure conditions, testing, calculation, and reporting are given for flexure specimens in Sections and , and for tension specimens in Sections and .
1.3 For the definitions of dry use and wet use , see and .
1.4 The values stated in inch-pound units are to be regarded as standard. The SI units given in parentheses are for information only.
The following precautionary caveat pertains only to the apparatus and test methods portions, Sections of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Test Requirements Significance and Use FIG. 1 FIG. 2 FIG. 3 |
3 | Apparatus TABLE 1 |
4 | Preparation of Finger Joint TABLE 2 FIG. 4 |
5 | Conditioning Testing in Flexure TABLE 3 FIG. 5 |
6 | Testing in Tension Exposure Conditions and Treatments FIG. 6 |
7 | Precision and Bias TABLE 4 |
8 | Keywords X1. REPORT FORMS X1.1 TABLE 5 |
9 | FIG. X1.1 |
10 | FIG. X1.2 |
11 | FIG. X1.2 |
12 | FIG. X1.3 |
13 | FIG. X1.3 |
14 | X2.1 FIG. X1.4 |
15 | X2.2 X3.1 |
16 | X4.1 FIG. X3.1 |