D6735-01 Standard Test Method for Measurement of Gaseous Chlorides and Fluorides from Mineral Calcining Exhaust Sources—Impinger Method
Published By | Publication Date | Number of Pages |
ASTM | 2001 | 10 |
ASTM D6735-01
Historical Standard: Standard Test Method for Measurement of Gaseous Chlorides and Fluorides from Mineral Calcining Exhaust Sources—Impinger Method
ASTM D6735
Scope
1.1 This method will measure the concentration of gaseous hydrochloric and hydrofluoric acids, and other gaseous chlorides and fluorides that pass through a particulate matter filter maintained at 177°C (350°F). This method is specific for sampling combustion effluent from mineral calcining industries and other stationary sources where the reactive/adsorptive nature of the particulate matter may affect measurements.
1.2 This method utilizes ion chromatography to quantify the aqueous samples, and thus measures only the C1– and F – ions.
1.3 Based on a one-hour sampling run, the method will provide results of known accuracy and precision for chloride and fluoride in-stack concentrations of 0.5 ppm (v) dry or greater. Extending the run duration and sampling a greater volume of effluent will extend the range to lower concentrations.
1.4 This method includes optional post-test quality assurance procedures to assess the bias of the test results, and optional paired sample train runs to assess the precision of test results.
Keywords
analyte spiking; gaseous chlorides and fluorides; HCl ; HF; hydrochloric acid gas; hydrofluoric acid gas; hydrogen chloride; hydrogen fluoride; impinger method; mineral calcining; paired trains
ICS Code
ICS Number Code 71.040.50 (Physicochemical methods of analysis)
DOI: 10.1520/D6735-01
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology |
2 | Summary of Test Method Significance and Use |
3 | Interferences Apparatus FIG. 1 |
4 | Reagents and Materials |
5 | Hazards Calibration and Standardization Procedure |
7 | Calculations Report |
8 | Precision and Bias Keywords X1. ADDITIONAL OPTIONAL PROCEDURES TO DOCUMENT THE ACCURACY AND PRECISION OF THIS METHOD X1.1 |
9 | X1.2 |