Historical Standard: Standard Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum

ASTM E1414

Scope

1.1 This test method utilizes a laboratory space so arranged that it simulates a pair of horizontally adjacent small offices or rooms separated by a partition and sharing a common plenum space. The partition either extends to the underside of a common plenum space or penetrates through it. In the prescribed configuration, special design features of the facility ensure that the only significant sound transmission path is by way of the ceiling and the plenum space

1.2 Within the limitations outlined in the significance statement, the primary quantity measured by this test method is the ceiling attenuation of a suspended ceiling installed in a laboratory environment. By accounting for receiving room sound absorption, the normalized ceiling attenuation may be determined.

1.3 The test method may also be used to evaluate the attenuation of composite ceiling systems comprised of the ceiling material and other components such as luminaires and ventilating systems.

1.4 The field performance of a ceiling system may differ significantly from the results obtained by this test method (see Section , Significance and Use, and Test Method E 336).

1.5 The procedures may also be used to study the additional sound insulation that may be achieved by other attenuation measures. This would include materials used either as plenum barriers or as backing for all or part of the ceiling.

1.6 The facility may also be used to study the performance of an integrated system comprising plenum, ceiling, and partition, tested as a single assembly.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

airborne sound attenuation; common ceiling plenum; suspended ceiling

ICS Code

ICS Number Code 91.120.20 (Acoustics in buildings. Sound insulation)

DOI: 10.1520/E1414-06

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
Summary of Test Method
Significance and Use
3 Test Signal
Test Arrangement
FIG. 1
FIG. 2
4 Test Specimen
Procedure
FIG. 3
5 Report
6 Precision and Bias
Keywords
TABLE 1
7 A1. MEASUREMENT OF NORMALIZATION FACTOR BY THE STEADY STATE METHOD
A1.1
A1.2
A2. LABORATORY ACCREDITATION
A2.1 Scope
A2.2 Referenced Documents
A2.3 General Requirements
A2.4 Requirements Specific to This Method
8 REFERENCES