Historical Standard: Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique

ASTM E1530

Scope

1.1 This test method covers a steady-state technique for the determination of the resistance to thermal transmission (thermal resistance) of materials of thicknesses less than 25 mm. For homogeneous opaque solid specimens of a representative thickness, thermal conductivity can be determined (see Note 1). This test method is useful for specimens having a thermal resistance in the range from 10 to 400 × 10-4 m2·K·W-1, which can be obtained from materials of thermal conductivity in the approximate range from 0.1 to 30 W·m-1·K-1 over the approximate temperature range from 150 to 600 K. It can be used outside these ranges with reduced accuracy for thicker specimens and for thermal conductivity values up to 60 W·m-1·K-1.

Note 1—A body is considered homogeneous when the property to be measured is found to be independent of specimen dimensions.

1.2 This test method is similar in concept to Test Method C518, but is modified to accommodate smaller test specimens, having a higher thermal conductance. In addition, significant attention has been paid to ensure that the thermal resistance of contacting surfaces is minimized and reproducible.

1.3 The values stated in SI units are to be regarded as standard. The additional values are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

heat flow meter; heat flux transducer; thermal conductance; thermal conductivity; thermal resistance; thin specimen: Thermal transmission properties–steady-state; Thin material specimens/applications; Composites; Heat flow meter method; Heat flux transducer (HFT); Thermal conductance/conductivity; Thermal resistance/resistivity

ICS Code

ICS Number Code n/a

DOI: 10.1520/E1530-11

PDF Catalog

PDF Pages PDF Title
1 Scope
Related Documents
Terminology
2 Summary of Test Method
Significance and Use
Apparatus
3 Sampling and Conditioning
Test Specimen
FIG. 1
4 Calibration
Procedure
TABLE 1
TABLE 2
TABLE 3
5 Calculation
6 FIG. 2
7 Report
Precision and Bias
Keywords
A1. TESTING OF THIN SPECIMENS LESS THAN 0.5 MM IN THICKNESS
A1.1
A1.2
A1.3
A1.4
8 A1.5
A2. TESTING OF LIQUIDS AND PASTES
A2.1
A2.2
A2.3
A2.4
A2.5
A3. SUMMARY OF INFORMATION FOR PRECISION AND BIAS STATEMENT
A3.1
A3.2
A3.3
TABLE A3.1
ASTM-E1530