ASTM-E2624 2009

$40.63

E2624-09 Standard Practice for Torque Calibration of Testing Machines and Devices

Published By Publication Date Number of Pages
ASTM 2009 8
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM E2624-09

Historical Standard: Standard Practice for Torque Calibration of Testing Machines and Devices

ASTM E2624

Scope

1.1 This practice covers procedures and requirements for the calibration of torque for static and quasi-static torque capable testing machines or devices. These may, or may not, have torque indicating systems and include those devices used for the calibration of hand torque tools. Testing machines may be calibrated by one of the three following methods or combination thereof:

1.1.1 Use of standard weights and lever arms.

1.1.2 Use of elastic torque measuring devices.

1.1.3 Use of elastic force measuring devices and lever arms.

1.1.4 Any of the methods require a specific uncertainty of measurement and a traceability derived from national standards of mass and length.

1.2 The procedures of 1.1.1, 1.1.2, and 1.1.3 apply to the calibration of the torque-indicating systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the torque-indicating system(s) to be calibrated and included in the report.

1.3 Since conversion factors are not required in this practice, either english units, metric units, or SI units can be used as the standard.

1.4 Torque values indicated on displays/printouts of testing machine data systemsbe they instantaneous, delayed, stored, or retransmittedwhich are Calibrated with provisions of 1.1.1, 1.1.2 or 1.1.3 or a combination thereof, and are within the ±1 % of reading accuracy requirement, comply with this practice.

1.5 The following applies to all specified limits in this standard: For purposes of determining conformance with these specifications, an observed value or a calculated value shall be rounded to the nearest unit in the last right-hand digit used in expressing the specification limit, in accordance with the rounding method of Practice E 29, for Using Significant Digits in Test Data to Determine Conformance with Specifications.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

calibration; resolution; torque range

ICS Code

ICS Number Code 19.060 (Mechanical testing)

DOI: 10.1520/E2624-09

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Significance and Use
3 Calibration Devices
Requirements for Torque Standards
Selection of Applied Torques
TABLE 1
4 Extraneous Factors
System Calibration
5 Basis of Calibration
Time Interval Between Calibrations
6 Certificate and Report
Keywords
X1. DETERMINING RESOLUTION OF THE TORQUE INDICATOR
X1.1
X1.2
X1.3 Procedure for Analog Type Torque Indicators
X1.4 Procedure for Non-Auto-Ranging Digital Type Torque Indicators
X1.5 Procedure for Auto-Ranging Digital Type Torque In-dicators
7 X2. SAMPLE UNCERTAINTY ANALYSIS FOR TORQUE
X2.1
X2.2
X2.3
X2.4
X2.5
X2.6
X2.7
X2.8
X2.9