E354-93(2006) Standard Test Methods for Chemical Analysis of High-Temperature, Electrical, Magnetic, and Other Similar Iron, Nickel, and Cobalt Alloys

Published By Publication Date Number of Pages
ASTM 2006 28
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 These test methods cover the chemical analysis of high-temperature, electrical, magnetic, and other similar iron, nickel, and cobalt alloys having chemical compositions within the following limits:

1.3 Methods for the determination of several elements not included in this standard can be found in Test Methods E 30 and Test Methods E 1019.

1.4 Some of the concentration ranges given in are too broad to be covered by a single method and therefore this standard contains multiple methods for some elements. The user must select the proper method by matching the information given in the Scope and Interference sections of each method with the composition of the alloy to be analyzed.

1.5 The values stated in SI units are to be regarded as standard. In some cases, exceptions allowed in Practice E 380 are also used.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section and in special ‘Warning’ paragraphs throughout these test methods.

1.6 This method covers the determination of manganese in concentrations from 0.05 to 2.00 percent.

1.7 This method covers the determination of phosphorus in concentrations from 0.002 to 0.08 %.

PDF Catalog

PDF Pages PDF Title
1 Scope
2 Referenced Documents
Significance and Use
Apparatus, Reagents, and Instrumental Practice
Hazards
Sampling
Interlaboratory Studies and Rounding Calculated Values
Scope
Summary of Method
3 Concentration Range
Stability of Color
Interferences
Reagents
Preparation of Calibration Curve
Procedure
4 Calculation
Precision and Bias
TABLE 1
5 Scope
Summary of Method
Concentration Range
Stability of Color
Interferences
Apparatus
Reagents
Preparation of Calibration Curve for Concentrations from 0.005 to 0.05 mg/100 mL
Preparation of Calibration Curve for Concentrations from 0.05 to 0.30 mg/100 mL
Procedure
Calculation
Precision
TABLE 2
6 TABLE 3
TABLE 4
7 TABLE 5
9 TABLE 6
11 TABLE 7
12 TABLE 8
TABLE 9
14 TABLE 10
16 TABLE 11
18 TABLE 12
19 TABLE 13
21 TABLE 14
27 TABLE 15
28 TABLE 16