Shopping Cart

No products in the cart.

ASTM-E515:2005 Edition

$35.75

E515-05 Standard Test Method for Leaks Using Bubble Emission Techniques

Published By Publication Date Number of Pages
ASTM 2005 3
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM E515-05

Historical Standard: Standard Test Method for Leaks Using Bubble Emission Techniques

ASTM E515

Scope

1.1 This test method covers procedures for detecting or locating leaks, or both, by bubble emission techniques. A quantitative measure is not practical. The normal limit of sensitivity for this test method is 4.5 X 10-10 mol/s (1 X 10-5 Std cm3/s).²

1.2 Two techniques are described:

1.2.1 Immersion technique, and

1.2.2 Liquid application technique.

Note 1—Additional information is available in ASME Boiler and Pressure Vessel Code, Section V, Article 10-Leak Testing, and Guide E 479.

1.3 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

bubble leak testing; film solution leak test; immersion leak test; leak testing; vacuum box leak testing

ICS Code

ICS Number Code 19.100 (Non-destructive testing)

DOI: 10.1520/E0515-05

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Summary of Test Method
Basis of Application
2 Significance and Use
Interferences
Immersion Technique
3 Liquid Application Technique
Precision and Bias
Keywords
FIG. 1
FIG. 2
ASTM-E515
$35.75