ASTM-F2082 2015
$40.63
F2082-15 Standard Test Method for Determination of Transformation Temperature of Nickel-Titanium Shape Memory Alloys by Bend and Free Recovery
Published By | Publication Date | Number of Pages |
ASTM | 2015 | 6 |
ASTM F2082-15
Historical Standard: Standard Test Method for Determination of Transformation Temperature of Nickel-Titanium Shape Memory Alloys by Bend and Free Recovery
ASTM F2082
Scope
1.1 This test method describes a procedure for determining the martensite-to-austenite transformation temperatures of either fully annealed or heat-treated nickel titanium alloys by measuring the deformation recovered during the thermal transformation.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
free recovery; nickel titanium; nitinol; shape memory; transformation temperature;
ICS Code
ICS Number Code 77.120.50 (Titanium and titanium alloys)
DOI: 10.1520/F2082-15