BS 7346-7:2006

$189.07

Components for smoke and heat control systems – Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks

Published By Publication Date Number of Pages
BSI 2006 46
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
3 Contents
0 Introduction 1
1 Scope 3
2 Normative references 4
3 Terms and definitions 5
4 Smoke and heat control system selection 10
5 Design fires 11
6 Vehicle exhaust pollution control 13
7 Natural dispersal smoke ventilation 14
8 Conventional mechanical extract 16
9 Impulse ventilation to achieve smoke clearance 18
10 Impulse ventilation to assist fire-fighting access 20
11 Impulse ventilation to protect means of escape 24
12 Smoke and heat exhaust ventilation systems (SHEVS) 25
13 Ductwork, fixings, and smoke dampers 26
14 Controls and power supplies 27
15 Pre-installation verification 30
16 Interaction with other fire protection systems and other building systems 31
17 Commissioning 33
18 Documentation to be supplied with heat and smoke control system 35
19 Maintenance and safety 37
Annexes
Annex A (informative) Computer-based models 38
Annex B (informative) Lighting, signage, public address and voice alarm systems 39
Bibliography 40
List of figures
Figure 1 – Typical mechanical ventilation using a ducted smoke dispersal system 15
Figure 2 – Typical mechanical ventilation using an impulse smoke dispersal system 17
Figure 3 – Typical mechanical ventilation using an impulse system for fire-fighter access 21
List of tables
Table 1 – Steady-state design fires 12
Table 2 – Checklist for commissioning of major components of a smoke and heat control system or SHEVS 34
4 Foreword
5 0 Introduction
0.1 Background to smoke control in car parks
1) to assist fire-fighters to clear smoke from a car park during and after a fire;
2) to provide clear smoke-free access for fire-fighters to a point close to the seat of the fire;
3) to protect means of escape from the car park.
a) To assist fire-fighters to clear smoke from a car park during and after a fire.
6 b) To provide clear smoke-free access to fire-fighters to a point close to the seat of the fire.
2) moving the smoke and heat from that location towards a specific extraction point or points;
3) creating a smoke free approach zone or bridgehead clear of the fire. This allows fire-fighters to assemble personnel and equipment in favourable conditions and fire-fighting operations to be carried out more quickly, safely and efficiently.
c) To protect means of escape from the car park.
7 0.2 Further considerations
1 Scope
8 2 Normative references
9 3 Terms and definitions
3.1 addressable fire detection system
3.2 aerodynamic free area
3.3 approving authority
3.4 bridgehead
3.5 ceiling jet
3.6 coefficient of discharge
3.7 computational fluid dynamics model (CFD model)
3.8 cross-flow ventilation
3.9 design fire
3.10 directed message
10 3.11 dispersal
3.12 element of structure
3.13 equivalent area
3.14 exhaust ventilation system
3.15 exhaust ventilator
3.16 extraction point
3.17 fire compartment
3.18 fire engineered solution
11 3.19 fire load
3.20 fire operational position
3.21 fire resistance
3.22 fire service override switch
3.23 fixing
3.24 frequency inverter
3.25 impulse
3.26 jet fan
3.27 impulse ventilation system (IVS)
3.28 integrity
3.29 means of escape
12 3.30 mechanical cross ventilation
3.31 multi criteria fire detection
3.32 natural cross ventilation
3.33 override control
3.34 pressure differential system
3.35 rate of rise heat detection
3.36 replacement air
3.37 signalling system
3.38 smoke clearance system
3.39 smoke control damper
13 3.40 smoke control zone
3.41 smoke and heat control system
3.42 smoke and heat exhaust ventilation system (SHEVS)
3.43 steady-state design method
3.44 steady-state design fire
3.45 time-dependent design fire
3.46 thrust
3.47 vehicle emission ventilation
3.48 zone model
14 4 Smoke and heat control system selection
4.1 Design objectives
4.2 Selection of objectives
15 5 Design fires
16 5.1 Car fires
Table 1 Steady-state design fires
5.2 Stores and storage within car parks
a) The type of combustible materials stored.
b) The amount and disposition of the fire load.
c) The degree of fire resisting enclosure if provided.
d) The provision of sprinklers.
17 6 Vehicle exhaust pollution control
6.1 General
6.2 Naturally ventilated car parks
6.3 Mechanical and natural ventilation of car parks
6.4 Mechanically ventilated car parks
18 6.5 Detailed quantitative assessment of contaminants
7 Natural dispersal smoke ventilation
7.1 Car parks which are open sided
7.2 Car parks which are not open sided
19 Figure 1 Typical mechanical ventilation using a ducted smoke dispersal system
20 8 Conventional mechanical extract
8.1 General
a) smoke detection;
b) rapid rate of rise heat detection;
c) multi-criteria fire detection;
d) a sprinkler flow switch;
e) a fire service override switch.
21 8.2 Performance recommendations for equipment
8.3 Calculation procedures
Figure 2 Typical mechanical ventilation using an impulse smoke dispersal system
22 9 Impulse ventilation to achieve smoke clearance
9.1 General
23 a) smoke detection;
b) rapid rate of rise heat detection;
c) multi-criteria fire detection;
d) sprinkler flow switch;
e) fire service override switch.
24 9.2 Calculation procedures
10 Impulse ventilation to assist fire-fighting access
10.1 System design criteria
25 Figure 3 Typical mechanical ventilation using an impulse system for fire-fighter access
26 a) smoke detection;
b) rapid rate of rise heat detection;
c) multi-criteria fire detection.
27 10.2 Equipment rating
28 11 Impulse ventilation to protect means of escape
11.1 System design objectives
11.2 System design criteria
11.3 Equipment rating
29 12 Smoke and heat exhaust ventilation systems (SHEVS)
a) If the SHEVS can meet the airflow requirements for vehicle exhaust emission control (see Clause 7) with a reduced volume flow rate compared to the requirements for smoke control, it might be used to fulfil both sets of requirements.
b) Where the SHEVS is designed to protect means of escape for occupants, the clear height should be at least as detailed in BS 7346-4 (i.e. 2.5 m or 0.8 times the ceiling height, if lower than 2.5 m).
c) Where the SHEVS is designed to provide a clear, smoke-free approach to the fire for fire-fighters, the clear height should be at least 1.75 m.
d) The design fire, whether steady-state or time-dependent, should be based on 5.1 rather than the car fire cited in BS 7346-4.
e) The system should be independent from any other ventilation or HVAC system in the building other than for the control of vehicle emission pollutants.
f) All other performance recommendations and calculation procedures should be as detailed in BS 7346-4 for steady-state designs,…
g) Openings should be provided to allow the air to enter or exit the car park. These inlets should conform to the recommendation…
30 Figure 4 Design regions for a single volume space
13 Ductwork, fixings, and smoke dampers
31 14 Controls and power supplies
14.1 General
14.2 Controls
a) smoke detection;
b) rapid rate of rise heat detection;
c) multi-criteria fire detection;
d) sprinkler flow switch.
32 14.3 Computerised control systems
14.4 Electrical power supplies
33 a) classified as LS60 in accordance with BS 7346-6:2005;
b) in accordance with BS 8434-2:2004; or
c) in accordance with BS EN 60702-1:2004.
34 15 Pre-installation verification
15.1 Zone modelling
15.2 CFD modelling
35 15.3 Selection of verification method
16 Interaction with other fire protection systems and other building systems
16.1 General
16.2 Sprinkler systems
16.3 Other ventilation systems
a) Wherever the vehicle exhaust fume ventilation is provided by a system independent of the smoke and heat control system, that system should close down in the event of the smoke and heat control system being initiated.
b) Any ducts or openings which form a part of the non-fire protective ventilation system and which penetrate between storeys or fire compartments should be closed at the boundary between storeys or fire compartments using fire-rated smoke dampers.
36 c) All smoke control dampers in that part of the HVAC system corresponding to the affected smoke control zone should move into their fire operational positions simultaneously with the HVAC fans.
d) The functions described in a) to c) should be tested after the system has been installed by simulating a fire detection signal in accordance with Clause 17.
e) If parts of the HVAC system are used in the smoke and heat control system, those parts of the HVAC system which are incorporated into the smoke and heat control system should follow all appropriate recommendations in this standard.
f) All smoke control dampers should be capable of being opened and closed by powered devices.
16.4 Lighting, signage, public address and voice alarm systems
16.5 Pressure differential systems
16.6 External/ground level escape routes
37 16.7 Security systems
16.8 Fire safety management
17 Commissioning
38 Table 2 Checklist for commissioning of major components of a smoke and heat control system or SHEVS
39 18 Documentation to be supplied with heat and smoke control system
18.1 General design recommendations
18.1.2 Fire-fighting
40 18.2 Detailed recommendations
18.2.1 System design documentation
a) A justification for the choice of design fire.
b) Where design calculations explicitly include wind pressure forces and/or wind pressure coefficients, identification of all zones of overpressure and suction on the building’s surface.
c) The locations of all exhaust ventilator outlets and replacement air openings in the building.
d) Assumptions and input parameters used in calculations of the external environment of the building.
e) Wind load, snow load, and low ambient temperature assessments for any ventilators.
f) Relative positions of the exhaust outlets and unprotected openings in neighbouring buildings, pedestrian areas and vehicle roadways in the neighbourhood of the building.
g) full details of all the inlet air provisions, locations and their method of operation;
h) for mechanical systems, the total volume of air to be provided;
i) the calculated air flow speed at the inlets for this air.
18.3 Installation, maintenance and testing documentation
18.4 Computer control software
41 19 Maintenance and safety
42 Annex A (informative) Computer-based models
A.1 General
A.2 Computer-based zone models
A.3 Computational fluid dynamics models
43 Annex B (informative) Lighting, signage, public address and voice alarm systems
B.1 Lighting and signage
B.2 Public address and voice alarm systems
44 Bibliography
[1] GREAT BRITAIN. The Building Regulations 2000. SI 2000, No. 2531, as amended. London: The Stationery Office.
[2] GREAT BRITAIN. The Building Standards (Scotland) Regulations 2001, No. 320 (as amended). London: The Stationery Office.
[3] GREAT BRITAIN. The Building Regulations (Northern Ireland) Statutory Rules 2000, No. 389. London: The Stationery Office.
[4] GREAT BRITAIN. The Building Regulations Approved Document B, Fire safety. London: The Stationery Office, 2000
[5] NORTHERN IRELAND. The Building Regulations (Northern Ireland) Technical Booklet E, Fire safety, 2005.
[6] GREAT BRITAIN. Scottish Building Standards Technical Handbooks. London: The Stationery Office.
[7] JOYEUX, D, CAJOT, L-G, SCHLEICH, J-B. Natural fires in closed car parks. Eurofire ’98, Belgium, 1998.
[8] Air treatment systems for car parks, Verein Deutscher Ingenieure, VDI 2053 (2004).
[9] GREAT BRITAIN. The Building Regulations Approved Document F, Ventilation. London: The Stationery Office, 2006.
[10] GREAT BRITAIN. The Building Regulations (Northern Ireland) Technical Booklet K, Ventilation, 1994.