BS 8488:2009+A1:2010
$142.49
Prefabricated wiring systems intended for permanent connection in fixed installations. Specification
Published By | Publication Date | Number of Pages |
BSI | 2010 | 28 |
This British Standard specifies safety requirements, together with associated tests, for prefabricated wiring systems incorporating installation couplers conforming to BS EN 61535 with a rated voltage up to and including 500 V a.c. and a maximum operating temperature not exceeding 70 °C for permanent connection in fixed installations. Prefabricated wiring systems are intended to be installed by instructed or skilled persons, including the connection and disconnection of installation couplers.
This British Standard includes tests to be conducted as part of the manufacturing process.
Text deleted.
NOTE 1 Prefabricated wiring systems are typically used in prefabricated houses, installation cavities (such as suspended floors and ceilings), cable tray systems, cable ladder systems, cable ducting systems, cable trunking systems, commercial showrooms, partition walls and in similar applications.
NOTE 2 In locations where special conditions prevail, additional requirements might apply, e.g. accessible areas might require IP4X connectors.
NOTE 3 A guide to use is provided in Annex A.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Foreword |
5 | 1 Scope 2 Normative references |
6 | 3 Terms and definitions |
8 | 4 Classification 5 !Marking and documentation” |
10 | 6 Construction |
11 | 7 !Wiring systems” |
12 | 8 Provision for earthing |
13 | 9 Protection against electric shock 10 Resistance to solid objects, dust and moisture |
14 | 11 Insulation resistance and electric strength 12 Clearances, creepage distances and distances through insulation 13 Resistance to heat, fire and tracking |
15 | 14 Electrical connections Table 1 �Prefabricated wiring systems intended for use in supply systems with a maximum voltage to earth of 150 V a.c. (rated impulse voltage 2.5 kV) |
16 | Table 2 �Prefabricated wiring systems intended for use in supply systems with a maximum voltage to earth of 300 V a.c. (rated impulse voltage 4.0 kV) |
17 | Annex A (informative) Guide to use |
18 | Figure A.1 Diagrammatic presentation of a typical prefabricated wiring system |
19 | Annex B (normative) Routine testing |
20 | Table B.1 Values for electrical tests |
21 | Annex C (normative) Test methods |
22 | Table C.1 Minimum insulation resistance |
23 | Table C.2 Electric strength |
25 | Bibliography |