Shopping Cart

No products in the cart.

BS 8488:2009+A1:2010

$142.49

Prefabricated wiring systems intended for permanent connection in fixed installations. Specification

Published By Publication Date Number of Pages
BSI 2010 28
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This British Standard specifies safety requirements, together with associated tests, for prefabricated wiring systems incorporating installation couplers conforming to BS EN 61535 with a rated voltage up to and including 500 V a.c. and a maximum operating temperature not exceeding 70 °C for permanent connection in fixed installations. Prefabricated wiring systems are intended to be installed by instructed or skilled persons, including the connection and disconnection of installation couplers.

This British Standard includes tests to be conducted as part of the manufacturing process.

Text deleted.

NOTE 1 Prefabricated wiring systems are typically used in prefabricated houses, installation cavities (such as suspended floors and ceilings), cable tray systems, cable ladder systems, cable ducting systems, cable trunking systems, commercial showrooms, partition walls and in similar applications.

NOTE 2 In locations where special conditions prevail, additional requirements might apply, e.g. accessible areas might require IP4X connectors.

NOTE 3 A guide to use is provided in Annex A.

PDF Catalog

PDF Pages PDF Title
4 Foreword
5 1 Scope
2 Normative references
6 3 Terms and definitions
8 4 Classification
5 !Marking and documentation”
10 6 Construction
11 7 !Wiring systems”
12 8 Provision for earthing
13 9 Protection against electric shock
10 Resistance to solid objects, dust and moisture
14 11 Insulation resistance and electric strength
12 Clearances, creepage distances and distances through insulation
13 Resistance to heat, fire and tracking
15 14 Electrical connections
Table 1 �Prefabricated wiring systems intended for use in supply systems with a maximum voltage to earth of 150 V a.c. (rated impulse voltage 2.5 kV)
16 Table 2 �Prefabricated wiring systems intended for use in supply systems with a maximum voltage to earth of 300 V a.c. (rated impulse voltage 4.0 kV)
17 Annex A (informative) Guide to use
18 Figure A.1 Diagrammatic presentation of a typical prefabricated wiring system
19 Annex B (normative) Routine testing
20 Table B.1 Values for electrical tests
21 Annex C (normative) Test methods
22 Table C.1 Minimum insulation resistance
23 Table C.2 Electric strength
25 Bibliography
BS 8488:2009+A1:2010