Air conditioners, liquid chilling packages, heat pumps, process chillers and dehumidifiers with electrically driven compressors. Determination of the sound power level – Heat pump water heaters

Published By Publication Date Number of Pages
BSI 2019 38
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies methods for testing the sound power level of air/water, brine/water, water/water and direct exchange/water heat pump water heaters and heat pump combination heaters with electrically driven compressors and connected to or including a domestic hot water storage tank for domestic hot water production.

This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system.

NOTE 1

Testing procedures for simultaneous operation for domestic hot water production and space heating are not treated in this standard. Simultaneous operation means that domestic hot water production and space heating generation occur at the same time and may interact.

NOTE 2

For space heating function, the requirements are given in EN 12102-1:2017 .

This European Standard only applies to water heaters which are supplied in a package of heat pump and storage tank. In the case of water heaters consisting of several parts with refrigerant connections, this European Standard applies only to those designed and supplied as a complete package.

This European Standard does not specify requirements for the quality of the used water.

PDF Catalog

PDF Pages PDF Title
2 National foreword
7 1 Scope
2 Normative references
8 3 Terms, definitions and symbols
3.1 Terms and definitions
3.2 Symbols, subscripts and units
9 4 Acoustic characteristics
10 5 Measurement procedure
5.1 General approach
11 5.2 Target hot water temperature Thw
5.3 Volumic power density (VPD)
5.4 Water tank filling
12 5.5 Water outlet temperature measurement
13 5.6 Method for units with VPD ≤ 10 W/l
5.6.1 Heat pump operation
5.6.2 Acoustic measurement
14 5.7 Method for units with VPD > 10 W/l
15 5.8 Frosting
5.9 Measurement of non-acoustic parameters
5.10 Volume air flow rate and available external static pressure
5.10.1 Non-ducted units
5.10.2 Ducted units
5.11 Rotation speed
16 6 Test conditions
7 Measuring requirements
18 8 Installation of the unit
8.1 General
19 8.2 Settings
8.2.1 General
8.2.2 Settings for non-ducted air source units
8.2.3 Setting the difference of temperature for heat pumps using a liquid as heat source
8.3 Ducted configurations
8.3.1 General
8.3.2 Ducts with bends
20 8.3.3 Duct construction
21 8.3.4 Static pressure measurement
22 8.4 Acoustic calculation
8.4.1 General
8.4.2 Duct end correction
23 8.4.3 Bend correction BC
24 9 Acoustic measurements methods
9.1 General
9.2 Test methods
25 9.3 Frequency range
10 Data management
10.1 Test report
10.1.1 General
10.1.2 Unit specification
10.1.3 Operating conditions, installation and environmental conditions
10.1.3.1 General
10.1.3.2 Measured values and results
26 10.2 Laboratory register
27 Annex A (informative)Typical configuration of heat pumps
30 Annex B (normative)Measurement procedure for heat pump water heaters with a direct heat exchanger between the sanitary cold water and the refrigerant
31 Annex C (normative)Target hot water temperature Thw
32 Annex D (informative)Example of measurement process for units with VPD > 10 W/l
35 Annex ZA (informative)Relationship between this European Standard and the ecodesign requirements of Commission Regulation (EU) No 814/2013 aimed to be covered
36 Annex ZB (informative)Relationship between this European Standard and the energy labelling requirements of Commission Delegated Regulation (EU) No 812/2013 aimed to be covered
BS EN 12102-2:2019