BS EN 12259-14:2020+A2:2024
$198.66
Fixed firefighting systems. Components for sprinkler and water spray systems – Sprinklers for residential applications
Published By | Publication Date | Number of Pages |
BSI | 2024 | 64 |
This document specifies requirements for the construction and performance of residential sprinklers as well as test methods for their type approval, which are operated by a change of state of an element or bursting of a glass bulb under the influence of heat, for use only in automatic sprinkler systems for domestic and residential applications as defined in EN 16925:− . This standard does not cover representative fire and other tests for special sprinklers that are intended to provide for specific fire hazards, nor does it cover fire and other tests for sprinklers for commercial and industrial sprinkler systems as in EN 12845. Those test requirements are covered by EN 12259-1. NOTE 1 All pressure data in this European Standard are given as gauge pressures in bar. NOTE 2 Sprinklers according to EN12259-1 can also be used in residential and domestic applications if the system is designed according to EN 12845.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Construction and performance 4.1 General 4.2 Dimensions and pressure rating 4.2.1 Dimensions 4.2.2 Pressure ratings 4.3 Nominal operating temperature |
11 | 4.4 Operating temperatures 4.5 Water flow and distribution 4.5.1 K-factor 4.5.2 Water distribution 4.5.2.1 Water distribution test – Horizontal surface |
12 | 4.5.2.2 Water distribution test – Vertical surface 4.5.3 Water Impingement Test 4.6 Function 4.7 Fire Test |
13 | 4.8 Strength of sprinkler body and deflector 4.8.1 Strength of frame 4.8.2 Flow endurance 4.8.3 Strength of deflector 4.9 Strength of release element 4.9.1 Glass bulb sprinklers |
14 | 4.9.2 Fusible link sprinklers 4.10 Leak resistance and hydrostatic strength 4.11 Heat exposure 4.11.1 General |
15 | 4.11.2 Additional heat exposure of glass bulb sprinklers 4.11.3 Thermal shock 4.12 Corrosion 4.12.1 Stress corrosion 4.12.2 Sulphur dioxide corrosion 4.12.3 Salt mist corrosion 4.12.4 Moist air 4.13 Water hammer |
16 | 4.14 Thermal response 4.14.1 Oven test 4.14.2 Room response test 4.15 Resistance to vibration 4.16 Resistance to impact 4.17 Resistance to low temperature 4.18 Resistance to heat 4.19 Test conditions 5 Marking 5.1 General 5.2 Identification number |
17 | 5.3 Nominal operating temperature and year of manufacture 5.4 Manufacturing location 5.5 Heat sensitive element supplier 5.6 Protective covers 5.7 Sidewall sprinklers 5.7.1 General 5.7.2 Horizontal sidewall sprinklers 5.8 Concealed sprinklers |
18 | 5.9 Removable recessed housing 6 Instruction charts 6.1 General 6.2 Installation Instructions |
20 | Annex A (normative)Conditions for tests |
21 | Annex B (normative)Water flow test |
23 | Annex C (normative)Water distribution test C.1 Water distribution test – Horizontal surface C.1.1 General C.1.2 Upright, pendant, flush, recessed and concealed sprinklers |
24 | C.1.3 Sidewall Sprinklers |
26 | C.2 Water distribution test – vertical surface C.2.1 Test method |
28 | C.3 Water impingement test |
29 | Annex D (normative)Fire test D.1 Extent of testing |
33 | D.2 Test arrangement D.2.1 Test room |
35 | D.2.2 Fire source |
36 | D.2.3 Sprinkler installation |
37 | D.3 Test method |
38 | D.4 Supplementary test |
39 | Annex E (normative)Function test E.1 Function test E.2 Verification function test |
41 | Annex F (normative)Strength of sprinkler body and deflector F.1 Strength of sprinkler bod |
42 | F.2 Flow endurance test F.3 Deflector strength test |
43 | Annex G (normative)Strength of release elements test G.1 Glass bulbs |
45 | G.2 Fusible links |
46 | Annex H (normative)Leak resistance tests H.1 Leak Test H.2 Hydrostatic Strength Test |
47 | Annex I (normative)Heat exposure I.1 High temperature test I.2 Additional testing of glass bulb sprinklers |
48 | Annex J (normative)Glass bulb sprinkler thermal shock test |
49 | Annex K (normative)Exposure and corrosion tests K.1 Stress corrosion K.1.1 Sample preparation K.1.2 Apparatus K.1.3 Procedure K.2 Sulphur dioxide corrosion K.2.1 Reagents for apparatus of 5 l volume |
50 | K.2.2 Apparatus K.2.3 Procedure |
51 | K.3 Salt mist corrosion K.3.1 Reagents K.3.2 Apparatus K.3.3 Procedure |
52 | K.4 Moist Air K.4.1 Performance criteria K.4.2 Procedure |
53 | Annex L (normative)Water hammer test |
54 | Annex M (normative)Thermal response test M.1 Oven heat test |
55 | M.2 Room heat test M.2.1 Flush, recessed or concealed sprinklers M.2.2 Sprinkler location and orientation M.2.3 Room dimensions and water supply |
56 | M.2.4 Fire source and distance to sprinkler |
59 | Annex N (normative)Vibration test N.1 Sample preparation and performance criteria N.2 Procedure |
60 | Annex O (normative)Impact test |
61 | Annex P (normative)Resistance to low temperature test |
62 | Annex Q (normative)Resistance to high temperature test |