This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits (leak detector) based on the measurement of pressure change. Leak detection kits are intended to be used with double skin, underground or above ground, pressurized or non-pressurized, tanks or pipework designed for water polluting liquids/fluids. The kits are usually composed of: – measuring device; – evaluation device; – alarm device; – pressure generator; – pressure relief device; – liquid stop device; – condensate trap.

PDF Catalog

PDF Pages PDF Title
4 Contents Page
8 1 Scope
2 Normative references
9 3 Terms, definitions, symbols and abbreviated terms
3.1 Terms and definitions
3.2 Symbols and abbreviated terms
11 4 Requirements
4.1 Effectiveness
4.1.1 General
4.1.2 Measure the pressure change
4.1.2.1 Measuring device for over pressure
4.1.2.2 Evaluation device for over pressure
12 4.1.2.3 Alarm device for over pressure
4.1.2.4 Measuring device for vacuum
4.1.2.5 Evaluation device for vacuum
14 4.1.2.6 Alarm device for vacuum
4.1.3 Replenishment rate of the medium (only if provided)
4.1.3.1 Vacuum and pressure generators with regulated flow rate
4.1.3.2 Pressure / vacuum generator with time regulated flow
15 4.1.4 Software (only if provided)
4.1.5 Function and tightness of leak detection kit
4.2 Durability of effectiveness
4.2.1 Durability of effectiveness against temperature
4.2.2 Durability of effectiveness against chemical attack
4.2.3 Durability of effectiveness against fatigue through cycling of pressure
4.2.4 Humidity measurement of the leak detection medium (only if provided)
16 4.3 Additional requirement
4.3.1 Over pressure change
4.3.2 Vacuum change
4.3.2.1 Liquid stop device
4.3.2.2 Condensate trap
17 5 Testing, assessment and sampling methods
5.1 Effectiveness
5.1.1 General
5.1.2 Measure the pressure change
5.1.2.1 Measuring device for over pressure
19 5.1.2.2 Evaluation device for over pressure
21 5.1.2.3 Alarm device for over pressure
22 5.1.2.4 Measuring device for vacuum
23 5.1.2.5 Evaluation device for vacuum
25 5.1.2.6 Alarm device for vacuum
5.1.3 Replenishment rate of the medium (only if provided)
5.1.3.1 Vacuum and pressure generators with regulated flow rate
26 5.1.3.2 Pressure/vacuum generator with time regulated flow
30 5.1.4 Software (only if provided)
5.1.4.1 Test equipment
5.1.4.2 Preparation
5.1.4.3 Procedure
5.1.4.4 Evaluation
31 5.1.5 Function and tightness of leak detection kits
5.1.5.1 Test equipment
5.1.5.2 Preparation
5.1.5.3 Procedure
5.1.5.4 Evaluation
32 5.2 Durability of effectiveness
5.2.1 Durability of effectiveness against temperature
5.2.1.1 Test equipment
5.2.1.2 Preparation
33 5.2.1.3 Procedure
34 5.2.1.4 Evaluation
35 5.2.2 Durability of effectiveness against chemical attack
5.2.2.1 Test equipment
5.2.2.2 Preparation
5.2.2.3 Procedure
36 5.2.2.4 Evaluation
5.2.3 Durability of effectiveness against fatigue through cycling of pressure
5.2.3.1 Test equipment
5.2.3.2 Preparation
5.2.3.3 Procedure
5.2.3.4 Evaluation
37 5.2.4 Humidity measurement of the leak detection medium (only if provided)
5.2.4.1 Test equipment
5.2.4.2 Preparation
5.2.4.3 Procedure
5.2.4.4 Evaluation
5.3 Additional tests
5.3.1 Device for over pressure
5.3.1.1 Pressure relief valve
38 5.3.2 Device for vacuum
5.3.2.1 Liquid stop device
40 5.3.2.2 Condensate trap
41 6 Assessment and verification of constancy of performance – AVCP
6.1 General
6.2 Type testing
6.2.1 General
42 6.2.2 Test samples, testing and compliance criteria
6.2.3 Test reports
6.2.4 Shared other party results
43 6.2.5 Cascading determination of the product type results
44 6.3 Factory production control (FPC)
6.3.1 General
45 6.3.2 Requirements
6.3.2.1 General
46 6.3.2.2 Equipment
6.3.2.3 Raw materials and components
6.3.2.4 Traceability and marking
6.3.2.5 Controls during manufacturing process
6.3.2.6 Product testing and evaluation
6.3.2.7 Non-complying products
47 6.3.2.8 Corrective action
6.3.2.9 Handling, storage and packaging
6.3.3 Product specific requirements
48 6.3.4 Procedure for modifications
6.3.5 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity
49 7 Marking, labelling and packaging
8 Environmental aspects
50 Annex A (normative) Calculation of the dry filter
A.1 Flow rate of air in the dry filter
A.1.1 Influences of temperature
A.1.2 Calculated loss of volume (due to influences to temperature)
51 A.1.3 Influence by leakage
A.1.4 Summarization
A.1.5 Calculation of the contents of the dry filter
52 Annex B (normative)Test of the over pressure device
B.1 Test equipment
B.2 Preparation
53 B.3 Procedure
B.3.1 Parametric test method
B.3.2 Test program
54 B.4 Evaluation
55 Annex C (informative)Environmental aspects
58 Annex ZA (informative)Clauses of this European Standard addressing the provisions of the EU Directive Construction Products Regulation 305/2011/EU