BS EN 1366-12:2014+A1:2019

$167.15

Fire resistance tests for service installations – Non-mechanical fire barrier for ventilation ductwork

Published By Publication Date Number of Pages
BSI 2019 36
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of EN 1366 specifies a method for determining the fire resistance of non-mechanical fire barriers installed in fire separating elements designed to withstand heat and the passage of smoke and gases at high temperature. This European Standard is used in conjunction with EN 1363-1 and EN 1366-2.

This European Standard is not suitable for testing non-mechanical fire barriers in suspended ceilings without modification.

This European Standard is not suitable for testing fire dampers, see EN 1366-2.

This European Standard is not suitable for testing such products as air transfer grilles, as the pressures and flows involved are different and may cause differing behaviour.

PDF Catalog

PDF Pages PDF Title
2 undefined
9 1 Scope
2 Normative references
3 Terms and definitions
10 4 Test equipment
4.1 General
4.2 Connecting duct
4.3 Volume flow measuring station
11 4.4 Condensing unit
4.5 Gas temperature measuring devices
4.6 Exhaust fan system
5 Test conditions
6 Test specimen
6.1 Size
6.2 Number of tests
6.2.1 General
12 6.2.2 Supporting construction
6.2.3 Method of installation in the supporting construction
6.2.4 Method of installation on to the supporting construction
6.2.5 Method of installation away from the supporting construction
13 6.3 Design
6.3.1 General
6.3.2 Orientation to be tested
6.3.3 Non-mechanical fire barriers installed within a wall or floor opening
6.3.4 Non-mechanical fire barriers mounted on to the face of a wall or floor
6.3.5 Non-mechanical fire barriers mounted remote from a wall or floor
6.3.5.1 General
6.3.5.2 Non-mechanical fire barriers mounted inside the furnace
6.3.5.3 Non-mechanical fire barriers mounted outside the furnace
14 7 Installation of test specimen
7.1 General
7.2 Supporting construction
7.3 Minimum separation
15 8 Conditioning
8.1 General
8.2 Water-based sealing materials
9 Application of instrumentation
9.1 Thermocouples
9.1.1 Furnace thermocouples (plate thermometers)
9.1.2 Unexposed surface temperature
9.2 Furnace pressure
9.2.1 General
9.2.2 Pressure differential measurement, furnace and connecting duct
16 10 Test procedure
10.1 Determination of leakage of connecting duct and measuring station
10.2 Fire test procedure
17 11 Performance criteria
18 12 Test report
19 13 Field of direct application of test results
13.1 Size of non-mechanical fire barrier
13.2 Non-mechanical fire barriers installed within structural openings
13.3 Non-mechanical fire barriers installed onto the face of a wall or a floor
13.4 Non-mechanical fire barriers remote from a wall or floor
20 13.5 Fire from above
13.6 Separation between non-mechanical fire barriers and between non-mechanical fire barriers and construction elements
13.7 Supporting constructions
33 Annex A (normative)EOTA TR026 – Characterization, Aspects of Durability and Factory Production Control for Reactive Materials, Components and Products
BS EN 1366-12:2014+A1:2019