BS EN 15254-4:2018
$142.49
Extended application of results from fire resistance tests. Non-loadbearing walls – Glazed constructions
Published By | Publication Date | Number of Pages |
BSI | 2018 | 32 |
This document provides guidance and, where appropriate, defines procedures for variations of certain parameters and factors associated with the design of fire resistant glazed elements which have been tested in accordance with EN 1364-1:2015, and classified according to EN 13501-2. Extended application of fire resistant glazed elements is based on test evidence. This standard only applies to vertically installed fire resistant glazed elements. This standard does not apply to door sets and openable windows according to EN 1634-1 and does not apply to curtain walling – full configuration or curtain walling – part configuration according to EN 1364-3 and EN 1364-4. Glass block assemblies and paver units and channel-shaped glass as defined in EN 1051-1 and EN 572-7 are excluded. There is currently insufficient information available to enable rules for extended application to be developed for these products.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
5 | European foreword |
6 | 1 Scope 2 Normative references |
7 | 3 Terms and definitions |
8 | 4 Principles 4.1 General principles |
9 | 4.2 Use of test evidence 4.2.1 General |
10 | 4.2.2 Reference tests 4.2.3 Use of pre-existing test data |
11 | 4.3 Combination of extended application 5 Specific changes to the glazing system 5.1 Exchange of the fire resistant glass 5.1.1 General |
12 | 5.1.2 Classification EI with the component that provides the fire resistance tested on the exposed face |
13 | 5.1.3 Classification EI with the component that provides the fire resistance tested on the unexposed face |
14 | 5.1.4 Classification E, EW |
15 | 5.2 Glass shapes 5.3 Increase of glass dimensions 5.4 Exchange of timber glazing beads |
16 | 5.5 Exchange of metal glazing beads |
17 | 5.6 Exchange of glazing system materials 5.7 Bead surface coverings |
18 | 6 Specific changes to the framing system 6.1 Exchange of frames 6.1.1 General |
19 | 6.1.2 Timber frames 6.1.3 Metal frames 6.2 Frame surface coverings 7 Changes to the fire resistant glazed element 7.1 Increase in dimensions and replication for fire resistant glazed elements with classification EW |
20 | 7.2 Decrease in dimensions for fire resistant glazed elements with classification EW |
22 | Annex A (informative) Examples for using this standard with regard to requested extended applications based on the reference test and pre-existing test data |
27 | Annex B (normative) Radiation calculations |
30 | Bibliography |