BS EN 15501:2015
$189.07
Thermal insulation products for building equipment and industrial installations. Factory made expanded perlite (EP) and exfoliated vermiculite (EV) products. Specification
Published By | Publication Date | Number of Pages |
BSI | 2015 | 48 |
This European Standard specifies the requirements for factory made expanded perlite and exfoliated vermiculite products which are used for the thermal insulation of building equipment and industrial installations with an operating temperature in the range of approximately 0 °C to + 1 100 °C.
Expanded perlite and exfoliated vermiculite products can be used below 0 °C but special tests regarding the suitability of the product in the intended application are advised (e.g. liquefaction of oxygen). Manufacturer’s advice should be heeded in all cases.
The products are manufactured in the form of boards, pipe sections, segments, prefabricated ware and special ware.
This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the structural performance of systems incorporating these products is not covered.
This European Standard does not specify the required level of a given property that is achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender.
Products with a declared thermal conductivity greater than 0,6 W/(mK) at 10 °C are not covered by this European Standard.
This European Standard does not cover products intended to be used for the insulation of the building structure.
The European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact transmission noise index.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Contents Page |
6 | European foreword |
8 | 1 Scope 2 Normative references |
10 | 3 Terms, definitions, symbols, units and abbreviated terms 3.1 Terms and definitions 3.1.1 Terms and definitions as given in EN ISO 9229:2007 |
11 | 3.1.2 Additional terms and definitions 3.2 Symbols, units and abbreviated terms 3.2.1 Symbols and units |
12 | 3.2.2 Abbreviated terms |
13 | 4 Requirements 4.1 General 4.2 For all applications 4.2.1 Thermal conductivity 4.2.2 Dimensions and tolerances 4.2.2.1 Linear dimensions |
14 | Table 1 — Dimensional tolerances 4.2.2.2 Squareness 4.2.2.3 Flatness 4.2.2.4 Pipe section linearity 4.2.3 Dimensional stability 4.2.4 Reaction to fire |
15 | 4.2.5 Durability characteristics 4.2.5.1 General 4.2.5.2 Durability of reaction to fire against ageing/degradation and high temperature 4.2.5.3 Durability of thermal resistance against ageing/degradation 4.2.5.4 Durability of thermal resistance against high temperature 4.3 For specific applications 4.3.1 General 4.3.2 Maximum service temperature |
16 | Table 2 — Levels for maximum service temperatures 4.3.3 Minimum service temperature 4.3.4 Compressive stress or compressive strength Table 3 — Levels for compressive stress at 10 % deformation or compressive strength NOTE EN 826 is not applicable to pipe sections, and compression behaviour is not determined. 4.3.5 Trace quantities of water soluble ions and the pH value |
17 | 4.3.6 Water vapour diffusion resistance 4.3.7 Short-term water absorption by partial immersion 4.3.8 Release of dangerous substances 4.3.9 Continuous glowing combustion 5 Test methods 5.1 Sampling |
18 | 5.2 Conditioning 5.3 Testing 5.3.1 General |
19 | Table 4 — Test methods, test specimens and conditions |
20 | 5.3.2 Thermal conductivity 5.3.3 Maximum service temperature 5.3.3.1 General 5.3.3.2 Test specimens |
21 | 5.3.4 Reaction to fire 6 Designation code where “i” shall be used to indicate the relevant class or level. 7 Assessment and Verification of the Constancy of Performance (AVCP) 7.1 General |
22 | 7.2 Product Type Determination (PTD) 7.3 Factory Production Control (FPC) 8 Marking and labelling |
23 | Annex A (normative) Factory production control Table A.1 — Minimum product testing frequencies |
24 | Table A.2 — Minimum product testing frequencies for the reaction to fire characteristics |
25 | Annex B (normative) Special conditions for the determination of organic content B.1 Principle B.2 Apparatus B.3 Procedure B.4 Calculation and expression of results B.5 Test report |
26 | Annex C (informative) Preparation of the test specimens to measure thermal conductivity C.1 Preparation of the test specimens to measure thermal conductivity C.2 Ageing |
27 | Annex D (informative) Product specific details for mounting and fixing for reaction to fire testing Table D.1 — Product parameters for EP / EV – flat products when tested as placed on the market or in standard test configuration of assemblies |
28 | Table D.2 — Installation Parameters for EP / EV – flat products as placed on the market |
29 | Table D.3 — Product parameters for EP / EV – pipe insulation products, as placed on the market |
30 | Table D.4 — Installation Parameters for EP / EV – pipe insulation products, as placed on the market |
31 | Table D.5 — Installation Parameters for EP / EV – flat products in standard test configuration of assemblies simulating end-use applications |
32 | Annex E (informative) Additional properties E.1 General E.2 Coefficient of thermal expansion E.3 Apparent and true porosity E.4 Air flow resistance E.5 Creep in compression E.6 Permeability to gases E.7 Bending strength E.8 Apparent density |
33 | Table E.1 — Test methods, test specimens, and conditions |
34 | Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation ZA.1 Scope and relevant characteristics |
35 | Table ZA.1— Relevant clauses for factory made expanded perlite (EP) and exfoliated vermiculite (EV) products and intended use |
36 | ZA.2 Procedures for AVCP of factory made expanded perlite (EP) and exfoliated vermiculite (EV) products ZA.2.1 Systems of AVCP Table ZA.2 — Systems of AVCP |
37 | Table ZA.3.1 — Assignment of AVCP tasks for factory made expanded perlite (EP) and exfoliated vermiculite (EV) products under system 1 for reaction to fire and system 3 (see Table ZA.2) |
38 | Table ZA.3.2 — Assignment of AVCP tasks for factory made expanded perlite (EP) and exfoliated vermiculite (EV) products under system 3 (see Table ZA.2) |
39 | Table ZA.3.3 — Assignment of AVCP tasks for factory made expanded perlite (EP) and exfoliated vermiculite (EV) products under combined system 4 for reaction to fire and system 3 (see Table ZA.2) ZA.2.2 Declaration of Performance (DoP) ZA.2.2.1 General |
40 | ZA.2.2.2 Content |
41 | ZA.2.2.3 Example of DoP |
43 | ZA.3 CE Marking and labelling |
44 | Figure ZA.1 — Example CE marking information of products under AVCP system 1 and system 3 |
45 | Bibliography |