BS EN 15714-5:2022
$167.15
Industrial valves. Actuators – Pneumatic linear actuators for industrial valves. Basic requirements
Published By | Publication Date | Number of Pages |
BSI | 2022 | 34 |
This document provides basic requirements for piston type pneumatic linear actuators for industrial valve, both double acting and single acting, used for on-off and modulating control duties. It includes criteria, method and guidelines for design, qualification, corrosion protection, control and testing. It does not apply to diaphragm actuators and to pneumatic actuators which are integral parts of control valves. Other requirements, or conditions of use, different from those indicated in this document, are subject to agreement, between the purchaser and the manufacturer/supplier, prior to order.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | 1 Scope 2 Normative references 3 Terms and definitions |
9 | 4 Classification/designation 4.1 Duty classification 4.1.1 General 4.1.2 On-off duty 4.1.3 Modulating duty |
10 | 4.2 Action 4.2.1 Double acting (DA) 4.2.2 Single acting (SA) 5 Motive energy 5.1 Operating medium 5.2 Quality 5.3 Pressure |
11 | 6 Actuator performance data 6.1 Minimum moving pressure 6.2 Operating time 6.3 Displacement volume 6.4 Dimensions and performances for double acting version |
13 | 6.5 Dimensions and performances for single acting version |
14 | 7 Basic design requirements 7.1 Safety requirements 7.2 Linear actuator attachment |
15 | 7.3 Nominal stroke 7.4 Endurance of linear actuators |
16 | 7.5 Leakage |
17 | 7.6 Environmental conditions 7.6.1 Ambient temperature 7.6.2 Enclosure protection 7.6.3 Corrosion protection |
19 | 7.7 Pressure connections 7.7.1 General 7.7.2 Remotely mounted pilot valves |
20 | 7.7.3 Direct mounted pilot valves |
21 | 7.8 Structural safety factors |
22 | 8 Optional equipment 8.1 Ancillaries 8.2 Manual operation device 8.3 Mechanical end stop adjustment |
23 | 8.4 Position indication 8.5 Bracket 8.6 Anti-rotation device 9 Conformity assessment 9.1 General 9.2 Type tests |
24 | 9.3 Control of production process |
26 | 10 Marking 10.1 Mandatory marking 10.2 Optional marking |
27 | 11 Documentation 12 Linear actuator selection guidelines |
28 | Annex A (normative)Endurance test procedure A.1 General A.2 Test equipment A.3 Test conditions A.4 Test procedure A.4.1 Initial tests |
29 | A.4.2 Endurance test A.4.3 Final tests A.5 Acceptance criteria |
30 | Annex B (informative)Actuator selection guidelines B.1 General B.2 Selection parameters B.2.1 General B.2.2 Valve questions B.2.3 Actuator questions |
31 | B.2.4 Ancillary questions B.2.5 Environmental conditions B.3 Actuator selection |