BS EN 1647:2018:2019 Edition
$167.15
Leisure accommodation vehicles. Caravan holiday homes. Habitation requirements relating to health and safety
Published By | Publication Date | Number of Pages |
BSI | 2019 | 44 |
This European Standard specifies requirements intended to ensure safety and health of persons using caravan holiday homes as defined in EN 13878, as temporary or seasonal accommodation. It specifies grades of resistance to snow loads and the stability of the structure of caravan holiday homes as well as the minimum information to be included in a user’s handbook. It also specifies the corresponding test methods.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
6 | European foreword |
7 | Introduction |
8 | 1 Scope 2 Normative references 3 Terms and definitions 4 Testing |
9 | 5 Design and construction 5.1 Occupancy 5.2 Ceiling height 5.3 Glazed areas 5.4 Doors 5.5 Glazing 5.6 Classification of thermal insulation and heating |
10 | 5.7 Roof space ventilation 5.8 Underfloor 5.9 Fire behaviour of materials 5.10 Stability (resistance to overturning) 5.11 Structural classification of caravan holiday homes |
11 | 6 Internal equipment 6.1 Bunks 6.1.1 General 6.1.2 Mattress and/or upholstery 6.1.3 Clearance 6.1.4 Protection against falling out |
12 | 6.1.5 Mechanical strength 6.1.6 Security of folding bunks 6.1.7 Access to high level bunks 6.1.8 Protection against entrapment |
13 | 6.2 Cooking appliance 6.3 Toilets 6.3.1 General 6.3.2 Toilets connected to water supply system 6.3.3 Toilets not connected to water supply system 6.4 Lighting 6.5 Appliances 7 Drinking water supply and drainage systems 7.1 Drinking water 7.1.1 Supply |
14 | 7.1.2 Materials 7.1.3 Supply coupling 7.2 Drainage system 8 Installations 8.1 Electricity 8.2 Liquefied petroleum gas (LPG) 8.3 Liquid fuel 9 Ventilation 9.1 Safety ventilation |
15 | 9.2 Additional ventilation 9.2.1 Larder and food storage 9.2.2 Fold-away beds 9.2.3 Wardrobes and bed lockers 10 Fire precautions 10.1 Means of escape 10.1.1 General 10.1.2 Escape path 10.1.3 Sanitation compartments |
16 | 10.1.4 Emergency doors 10.1.5 Interior doors 10.1.6 Emergency windows and emergency panels |
17 | 10.1.7 Obstruction of doors, escape paths or emergency exits 10.2 Protection of surfaces adjacent to heat generating appliances |
18 | 10.3 Protection of flammable elements 10.3.1 Rigid and guided elements 10.3.2 Non-guided elements 10.4 Hotplates 11 Warning notice 11.1 Provision of warning notice |
19 | 11.2 Content of warning notice 12 User’s handbook |
21 | Annex A (normative) Thermal insulation — Method of calculation (see 5.6) |
26 | Annex B (normative) Snow Load Test |
28 | Annex C (normative) Clear height over bunks (see 6.1.3) |
29 | Annex D (normative) Strength of protection against falling out of bunks (see 6.1.4.3) |
30 | Annex E (normative) Mechanical strength of bunks (see 6.1.5) |
32 | Annex F (normative) Security of folding bunks (see 6.1.6) |
33 | Annex G (normative) Safety of access to high level bunks (see 6.1.7) |
35 | Annex H (normative) Measurement of gaps (see 6.1.8) |
37 | Annex I (normative) Test equipment |
39 | Annex J (informative) Environmental aspects |
40 | Annex K (informative) Types of socket outlet in Europe |
42 | Bibliography |