BS EN 378-3:2016 – TC:2020 Edition

$186.33

Tracked Changes. Refrigerating systems and heat pumps. Safety and environmental requirements – Installation site and personal protection

Published By Publication Date Number of Pages
BSI 2020 61
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard specifies the requirements for the safety of persons and property, provides guidance for the protection of the environment and establishes procedures for the operation, maintenance and repair of refrigerating systems and the recovery of refrigerants. The term ‘refrigerating system’ used in this European Standard includes heat pumps. This Part 3 of the European Standard is applicable to the installation site (plant space and services). It specifies requirements on the site for safety, which may be needed because of, but not directly connected with, the refrigerating system and its ancillary components. This standard applies: a) to refrigerating systems, stationary or mobile, of all sizes except to vehicle air conditioning systems covered by a specific product standard e.g. ISO 13043; b) to secondary cooling or heating systems; c) to the location of the refrigerating systems; d) to replaced parts and added components after adoption of this standard if they are not identical in function and in the capacity. Systems using refrigerants other than those listed in of FprEN 378-1:2016, Annex E are not covered by this standard. This standard does not apply to goods in storage. This standard is not applicable to refrigerating systems which were manufactured before the date of its publication as a European Standard except for extensions and modifications to the system which were implemented after publication. This standard is applicable to new refrigerating systems, extensions or modifications of already existing systems, and for existing stationary systems, being transferred to and operated on another site. This standard also applies in the case of the conversion of a system for another refrigerant type, in which case conformity with the relevant clauses of parts 1 to 4 of the standard shall be assessed.

PDF Catalog

PDF Pages PDF Title
35 Contents Page
38 European foreword
39 Introduction
40 1 Scope
2 Normative references
41 3 Terms, definitions and abbreviated terms
4 Location of refrigerating equipment
4.1 General
4.2 Refrigerating equipment located in the open air
42 4.3 Refrigerating equipment located in a machinery room
4.4 Refrigerating equipment located in the occupied space
4.5 Refrigerating equipment located in an unoccupied space not designated a machinery room
43 4.6 Refrigerating equipment located in a ventilated enclosure within an occupied space
4.7 Piping duct or shaft
5 Machinery rooms
5.1 Access to machinery rooms
5.2 Venting from or through the machinery room
5.3 Combustion equipment and air compressors
5.4 Open flame
5.5 Storage
44 5.6 Remote emergency switch
5.7 Exterior openings of the machinery room
5.8 Piping and ducting
5.9 Normal lighting
5.10 Emergency lighting
5.11 Dimensions and accessibility
45 5.12 Doors, walls and ducts
5.12.1 Doors and openings
5.12.2 Emergency
5.12.3 Walls, floor and ceiling
5.12.4 Service ducts
5.12.5 Ventilation ducts
5.13 Ventilation
5.13.1 General
46 5.13.2 Ventilation for normal operating conditions or when machinery room is occupied
5.13.3 Emergency mechanical ventilation
5.13.4 Required airflow for emergency mechanical ventilation
5.13.5 Mechanical ventilation openings
5.14 Machinery rooms for groups A2L, A2, A3, B2L, B2 and B3 refrigerants
5.14.1 General
5.14.2 Location
5.14.2.1 General
47 5.14.2.2 Emergency exhaust ventilation
5.14.3 Additional requirements for R-717
5.14.3.1 Drainage
5.14.3.2 Specific equipment for emergency washing
5.14.3.3 Fire sprinkler systems
48 5.14.4 Maximum surface temperature
5.14.5 Doors and openings
6 Requirements for alternative provisions
6.1 General
6.2 Occupied space
6.3 Ventilation
6.3.1 General
6.3.2 Dilution transfer openings (air transfer openings for dilution) for natural convection
49 6.3.3 Mechanical ventilation
6.3.3.1 Required airflow
50 6.3.3.2 Mechanical ventilation openings
6.3.3.3 Operation of mechanical ventilation
6.4 Safety shut off valves
6.4.1 General
6.4.2 Location
6.4.3 Design
7 Electrical installations
7.1 General requirements
51 7.2 Main power supply
7.3 Electrical equipment in machinery rooms with refrigerating systems containing flammable refrigerants
8 Safety alarms
8.1 General
8.2 Alarm system power
8.3 Alarm system warning
8.4 Additional alarm system requirements for R-717 systems with charges above 3 000 kg
52 9 Detectors
9.1 General
9.2 Location of detectors
9.3 Type and performance of detectors
9.3.1 General
9.3.2 Refrigerant detectors for A2, A2L, B2L (except for R-717), B2, A3 and B3 refrigerants
53 9.3.3 R-717 detectors
9.4 Installation
10 Instruction manuals, notices and inspections
10.1 Instruction manual
54 10.2 Warning notice
10.3 Visual inspection of the site
10.4 Maintenance of the site
11 Heat sources and temporary high temperatures at the site
56 Anhang A (informative) Personal protective equipment
A.1 General requirements
A.1.1 Type of protective equipment
A.1.2 Accessibility
A.1.3 Location
A.1.4 Check and maintenance
A.1.5 Temperature
A.1.6 Respirators
57 A.2 Normal use
A.3 Emergency use
A.3.1 General
A.3.2 Respiratory protective devices
A.3.3 First aid equipment
58 Bibliography