Shopping Cart

No products in the cart.

BS EN 4612-008:2019 – TC:2020 Edition

$134.27

Tracked Changes. Aerospace series. Cables, electrical, for general purpose, single and multicore assembly. XLETFE Family. Jacketed or screened and jacketed – Silver plated copper. Operating temperatures, between – 65 °C and 150 °C. Single extruded wall for open applications, with jacket and screen (braid). UV laser printable. Product standard

Published By Publication Date Number of Pages
BSI 2020 31
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies the characteristics of UV laser printable jacket, silver plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft operating at temperatures between – 65 °C and 150 °C, operating at voltages not exceeding 600 V rms at sea level. This insulation system has been used in aerospace applications using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user. These cables are suitable for airframe use without additional protection when the jacket is present. When the jacket is stripped back the cores may need additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.

PDF Catalog

PDF Pages PDF Title
1 compares BS EN 4612-008:2019
2 TRACKED CHANGES
Text example 1 — indicates added text (in green)
3 BS EN 4612-008:20112019
Compliance with a British Standard cannot confer immunity from legal obligations.
Amendments/corrigenda issued since publication
6 ForewordEuropean foreword
8 4.1 Materials
4.2 Construction
9 Table 1 — MulticoreSingle and multicore screened and jacketed
10 4.3 Colour coding of cores and jacket
15 A.1 The filling factor Kf is given by the following formula
A.3 Coverage
17 undefined
21 1 Scope
2 Normative references
3 Terms, definitions and symbols
22 4 Materials and construction
4.1 Materials
4.2 Construction
24 4.3 Colour coding of cores
5 Required characteristics
27 6 Quality assurance
28 7 Designation
8 Identification and marking
9 Packaging, labelling and delivery lengths
10 Technical specification
29 Annex A (normative)Formulae for calculating braid details
A.1 The filling factor Kf is given by the following formula
A.2 Lay factor
A.3 Coverage
BS EN 4612-008:2019 - TC
$134.27