BS EN 492:2012+A2:2018
$198.66
Fibre-cement slates and fittings. Product specification and test methods
Published By | Publication Date | Number of Pages |
BSI | 2018 | 52 |
This European Standard specifies the technical requirements and establishes methods of control and test as well as acceptance conditions for fibre-cement slates and their fibre-cement fittings for one or more of the following uses:
-
roofing;
-
internal wall finishes;
-
external wall and ceiling finishes.
This European Standard applies to fibre-cement slates with a height dimension h (see Clause 4) not exceeding 850 mm for overlapping assembly. For the purpose of this European Standard, fibre-cement slates have been classified according to their bending moment.
This European Standard covers fibre-cement slates reinforced with fibres of different types as specified in 5.1.1.
This European Standard does not include calculations with regard to works, design requirements, installation techniques, wind uplift or rain proofing of the installed products.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | 1 Scope 2 Normative references |
8 | 3 Terms and definitions |
9 | 4 Symbols and abbreviations |
10 | 5 Product requirements 5.1 General 5.1.1 Composition 5.1.2 Appearance and finish 5.2 Dimensions and tolerance 5.2.1 General 5.2.2 Thicknesses |
11 | 5.2.3 Tolerances on nominal dimensions 5.3 Physical requirements and characteristics for fibre-cement slates 5.3.1 General 5.3.2 Apparent density 5.3.3 Mechanical characteristics 5.3.4 Water impermeability |
12 | 5.4 Durability requirements 5.4.1 General 5.4.2 Freeze-thaw 5.4.3 Heat-rain 5.4.4 Warm water 5.4.5 Soak-dry 5.5 Fire and safety 5.5.1 External fire performance 5.5.2 Reaction to fire 5.5.3 Release of dangerous substances |
13 | 5.6 Product information 6 !Assessment and verification of constancy of performance — AVCP 6.1 General 6.2 Type testing 6.2.1 General |
14 | 6.2.2 Test samples, testing and compliance criteria 6.2.3 Test reports 6.3 Factory production control (FPC) 6.3.1 General |
15 | 6.3.2 Requirements 6.3.2.1 General |
16 | 6.3.2.2 Equipment 6.3.2.3 Raw materials and components 6.3.2.4 Traceability and marking 6.3.2.5 Controls during manufacturing process 6.3.2.6 Product testing and evaluation |
17 | 6.3.2.7 Non-complying products |
18 | 6.3.2.8 Corrective action 6.3.2.9 Handling, storage and packaging 6.3.3 Product specific requirements 6.3.4 Initial inspection of factory and of FPC |
19 | 6.3.5 Continuous surveillance of FPC 6.3.6 Procedure for modifications 6.4 Inspection of a consignment of finished products 7 Test methods 7.1 General 7.2 Dimensional tests 7.2.1 Preparation of specimen |
20 | 7.2.2 Apparatus 7.2.3 Procedure 7.2.3.1 Length and width 7.2.3.2 Thickness 7.2.4 Expression and interpretation of results 7.2.4.1 Length and width 7.2.4.2 Thickness 7.3 Tests for physical performance and characteristics 7.3.1 Apparent density 7.3.1.1 Preparation of specimen 7.3.1.2 Apparatus 7.3.1.3 Procedure |
21 | 7.3.1.4 Expression and interpretation of results 7.3.2 Mechanical characteristics: Breaking load test 7.3.2.1 Preparation of specimens 7.3.2.2 Apparatus |
22 | 7.3.2.3 Procedure |
23 | 7.3.2.4 Expression and interpretation of results 7.3.3 Water impermeability 7.3.3.1 Preparation of specimens 7.3.3.2 Apparatus 7.3.3.3 Procedure 7.3.3.4 Expression and interpretation of results |
24 | 7.3.4 Warm water 7.3.4.1 Preparation of specimens 7.3.4.2 Apparatus 7.3.4.3 Procedure 7.3.4.4 Expression and interpretation of results 7.3.5 Soak-dry 7.3.5.1 Preparation of specimens |
25 | 7.3.5.2 Apparatus 7.3.5.3 Procedure 7.3.5.4 Expression and interpretation of results: |
26 | 7.4 Tests for climatic performance 7.4.1 Freeze-thaw 7.4.1.1 Preparation of specimens 7.4.1.2 Apparatus 7.4.1.3 Procedure |
27 | 7.4.1.4 Expression and interpretation of results 7.4.2 Heat-rain 7.4.2.1 Preparation of specimens 7.4.2.2 Apparatus |
28 | 7.4.2.3 Procedure 7.4.2.4 Expression and interpretation of results 7.5 Test for fire performance 7.5.1 Test for external fire performance 7.5.1.1 Slates satisfying the requirements for the external fire performance, due to the deemed to satisfy list 7.5.1.2 Other slates |
29 | 7.5.2 Test for reaction to fire 7.5.2.1 Slates and fittings satisfying the requirements for the fire reaction Class A1 without the need for testing 7.5.2.2 Other slates and fittings |
36 | 8 Marking, labelling and packaging |
37 | Annex A (normative)Consignment inspection sampling |
38 | Annex B (normative)Statistical method for determining the corresponding wet values or revised dry specifications for the bending moment when carrying out the dry method of test for quality control purposes B.1 Procedure B.2 Determination of the correlation between the results of testing wet and dry specimens |
39 | B.3 Determination of the regression line B.4 Determination of a value for wet testing from an obtained value for dry testing |
40 | B.5 Determination of the minimum value specified for dry testing xstd corresponding to the minimum value specified for wet testing in this standard ystd |
42 | Annex C (informative)Examples C.1 Examples of dimension h |
44 | C.2 Examples of fibre-cement slates installed showing lines of fixing |
45 | Annex D (normative)Requirements of Decision 2001/671/EC regarding the external fire performance of roof coverings expressed following the classes defined in EN 13501-5 |
47 | Annex ZA (informative)#Relationship of this European Standard with Regulation [EU] No. 305/2011 |