Shopping Cart

No products in the cart.

BS EN 60255-151:2009:2010 Edition

$167.15

Measuring relays and protection equipment – Functional requirements for over/under current protection

Published By Publication Date Number of Pages
BSI 2010 36
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60255-151:2009 specifies minimum requirements for over/under current relays. It includes a specification of the protection function, measurement characteristics and time delay characteristics. Defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions.

PDF Catalog

PDF Pages PDF Title
6 English
CONTENTS
8 1 Scope and object
2 Normative references
3 Terms and definitions
10 4 Specification of the function
4.1 General
4.2 Input Energizing quantities / energizing quantities
Figures
Figure 1 – Simplified protection function block diagram
11 4.3 Binary input signals
4.4 Functional logic
12 Figure 2 – Overcurrent independent time characteristic
Figure 3 – Undercurrent independent time characteristic
13 Figure 4 – Dependent time characteristic
15 Figure 5 – Definite time reset characteristic
16 Figure 6 – Definite time reset characteristic (alternative solution with instantaneous reset after relay operation)
17 Figure 7 – Dependent time reset characteristic
18 4.5 Binary output signals
4.6 Additional influencing functions/conditions
4.7 Specific characteristics
Figure 8 – Dependent time reset characteristic (alternative solution with instantaneous reset after relay operation)
19 5 Performance specification
5.1 Accuracy related to the characteristic quantity
Figure 9 – Voltage restrained characteristics
Figure 10 – Voltage controlled characteristics
20 5.2 Accuracy related to the operate time
5.3 Accuracy related to the reset time
Tables
Table 1 – Multiplier factor on operated time assigned error
21 5.4 Transient performance
5.5 Current transformer requirements
Table 2 – Multiplier factor on reset time assigned error
22 6 Functional test methodology
6.1 General
6.2 Determination of steady state errors related to the characteristic quantity
25 6.3 Determination of steady state errors related to the start and operate time
6.4 Determination of steady state errors related to the reset time
Table 3 – Test points for overcurrent elements
Table 4 – Test points for undercurrent elements
26 6.5 Determination of transient performance
Table 5 – Test points for overcurrent elements
Table 6 – Test points for undercurrent elements
27 Figure 11 – Typical test waveform for transient overreach
28 Figure 12 – Test waveform
Table 7 – Recommended values for the test
29 7 Documentation requirements
7.1 Type test report
7.2 Other user documentation
31 Annex A (normative) Constants for dependent time operating and reset characteristics
Table A.1 – Constants for dependent time operating and reset characteristics
32 Annex B (informative) Reset time determination for relays with trip output only
Figure B.1 – Dependent reset time determination
33 Bibliography
BS EN 60255-151:2009
$167.15