BS EN 60512-99-001:2012
$102.76
Connectors for electronic equipment. Tests and measurements – Test schedule for engaging and separating connectors under electrical load. Test 99a: Connectors used in twisted pair communication cabling with remote power
Published By | Publication Date | Number of Pages |
BSI | 2012 | 16 |
This part of IEC 60512 is used for the assessment of connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO/IEC 11801 Class D, or better, balanced cabling in support of IEEE Std 802.3at™-2009 (PoE Plus – Power over Ethernet Plus).
The object of this standard is to detail a test schedule to determine the ability of connectors to withstand a minimal number of engagements and separations when an electrical current is being passed through the connector in accordance with IEC 60512-9-3.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
7 | 1 Scope and object 2 Normative references 3 General |
8 | 4 Preparation of specimen 5 Test circuit requirements 5.1 General 5.2 Voltage and current Figure 1 – Test circuit details |
9 | 5.3 Auxiliary equipment 6 Tests and test schedule 6.1 Test group UEL 1 Table 1 – Test group UEL 1 |
12 | Annex A (informative)Test voltage and current setting instructions |
13 | Bibliography |