BS EN 60749-5:2017 – TC:2020 Edition
$112.35
Tracked Changes. Semiconductor devices. Mechanical and climatic test methods – Steady-state temperature humidity bias life test
Published By | Publication Date | Number of Pages |
BSI | 2020 | 34 |
IEC 60749-5:2017(E) provides a steady-state temperature and humidity bias life test for the purpose of evaluating the reliability of non-hermetic packaged solid-state devices in humid environments. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) correction of an error in an equation; b) inclusion of notes for guidance; c) clarification of the applicability of test conditions.
PDF Catalog
PDF Pages | PDF Title |
---|---|
18 | National foreword |
23 | CONTENTS |
24 | FOREWORD |
26 | 1 Scope 2 Normative references 3 Terms and definitions 4 General |
27 | 5 Equipment 5.1 Equipment summary 5.2 Temperature and relative humidity 5.3 Devices under stress 5.4 Minimizing release of contamination 5.5 Ionic contamination 5.6 Deionized water 6 Test conditions 6.1 Test conditions summary 6.2 Temperature, relative humidity and duration Table 1 – Temperature, relative humidity and duration |
28 | 6.3 Biasing guidelines 6.4 Biasing choice and reporting |
29 | 7 Procedures 7.1 Mounting 7.2 Ramp-up 7.3 Ramp-down 7.4 Test clock 7.5 Bias 7.6 Read-out Table 2 – Criteria for choosing continuous or cyclical bias |
30 | 7.7 Handling 8 Failure criteria 9 Safety 10 Summary |