BS EN 60794-1-23:2012:2013 Edition
$102.76
Optical fibre cables – Generic specification. Basic optical cable test procedures. Cable element test methods
Published By | Publication Date | Number of Pages |
BSI | 2013 | 20 |
This part of IEC 60794 applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors.
The object of this part of IEC 60794 is to define test procedures to be used in establishing uniform requirements for the geometrical, material, mechanical, environmental properties of optical fibre cable elements.
Throughout the document the wording “optical cable” may also include optical fibre units, microduct fibre units, etc.
General requirements and definitions are given in IEC 60794-1-20 and a complete reference guide to test method of all types in the IEC 60794-1-2.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | CONTENTS |
8 | 1 Scope and object 2 Normative references 3 Method G1: Bend test for cable elements 3.1 Object 3.2 Sample 3.3 Apparatus |
9 | 3.4 Procedure 3.5 Requirements 3.6 Details to be specified 4 Method G2: Ribbon dimensions and geometry – Visual method 4.1 Object 4.2 Sample 4.3 Apparatus 4.4 Procedure 4.4.1 General 4.4.2 Method 1 |
10 | 4.4.3 Method 2 4.5 Requirements 4.6 Details to be specified 4.7 Definitions of ribbon dimensions and geometry 4.7.1 General 4.7.2 Width and height 4.7.3 Basis line 4.7.4 Fibre alignment |
11 | 5 Method G3: Ribbon dimensions – Aperture gauge 5.1 Object 5.2 Sample 5.3 Apparatus 5.4 Procedure Figures Figure 1 – Cross-sectional drawing illustrating fibre ribbon geometry |
12 | 5.5 Requirement 5.6 Details to be specified 6 Method G4: Ribbon dimensions – Dial gauge (Test deleted) 7 Method G5: Ribbon tear (separability) 7.1 Object 7.2 Sample Figure 2 – Aperture gauge |
13 | 7.3 Apparatus 7.4 Procedure 7.5 Requirements 7.6 Details to be specified Figure 3 – Sample preparation |
14 | 8 Method G6: Ribbon torsion 8.1 Object 8.2 Sample 8.3 Apparatus 8.4 Procedure 8.5 Requirements 8.6 Details to be specified Figure 4 – Separability procedure |
15 | 9 Method G7: Tube kinking 9.1 Object 9.2 Sample 9.3 Apparatus Figure 5 – Torsion test |
16 | 9.4 Procedure 9.5 Requirements Table 1 – Examples of test apparatus dimensions: |
17 | 9.6 Details to be specified 10 Method G8: Ribbon residual twist test 10.1 Object 10.2 Sample 10.3 Apparatus Figure 6 – Tube kinking test |
18 | 10.4 Procedure 10.5 Requirements 10.6 Details to be specified |